R0E0200F2EMU00 Renesas Electronics America, R0E0200F2EMU00 Datasheet - Page 58

no-image

R0E0200F2EMU00

Manufacturer Part Number
R0E0200F2EMU00
Description
EMULATOR E200F FOR SH7780 SRS
Manufacturer
Renesas Electronics America
Series
SuperH®r
Type
In-Circuit Emulatorr
Datasheet

Specifications of R0E0200F2EMU00

Contents
Emulator Board, Cables, Software and Documentation
For Use With/related Products
SH7780
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
• Trace acquisition condition
• Displaying a trace
• Branch trace
50
Do not set the trace-end condition for the SLEEP instruction and the branch instruction
according to which the delay slot becomes the SLEEP instruction.
When [I-BUS, M-Bus & Branch] is selected and the trace acquisition condition is set for the
M-bus and I-bus with the Event Condition, set the M-bus condition and the I-bus condition for
[Event Condition 1] and [Event Condition 2], respectively.
If the settings of [I-Trace mode] are changed during execution of the program, execution will
be suspended. (The number of clock cycles to be suspended during execution of the program is
a maximum of about 51 peripheral clock cycles (Pφ) + 15 bus clock cycles (Bφ). If the
peripheral clock (Pφ) is 33.3 MHz and the bus clock (Bφ) is 66.6 MHz, the program will be
suspended for 1.757 μs.)
If a trace is displayed during execution of the program, execution will be suspended to acquire
the trace information. (The number of clock cycles to be suspended during execution of the
program is a maximum of about 20480 peripheral clock cycles (Pφ) + 4096 bus clock cycles
(Bφ). If the peripheral clock (Pφ) is 33.3 MHz and the bus clock (Bφ) is 66.6 MHz, the
program will be suspended for 676.52 μs.)
If breaks occur immediately after executing non-delayed branch and TRAPA instructions and
generating a branch due to exception or interrupt, a trace for one branch will not be acquired
immediately before such breaks.
However, this does not affect on generation of breaks caused by a BREAKPOINT and a break
before executing instructions of Event Condition.