M3062PT3-CPE-4 Renesas Electronics America, M3062PT3-CPE-4 Datasheet - Page 98

no-image

M3062PT3-CPE-4

Manufacturer Part Number
M3062PT3-CPE-4
Description
DEV COMPACT EMULATOR M16C/26A,28
Manufacturer
Renesas Electronics America
Type
In Circuit Debuggerr
Datasheet

Specifications of M3062PT3-CPE-4

Contents
Compact Emulator, IDE, Assembler and Linker
For Use With/related Products
M16C/62P
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
M3062PT3-CPE User’s Manual
REJ10J1007-0400 Rev.4.00 July 29, 2009
Notes on Address-Match Breaks:
Notes on Address-Match Interrupts:
Notes on Software Breaks:
Note on the Watchdog Timer:
Note on Protect Register:
As the processing speed of setting and canceling address-match breaks is relatively fast, you can save the times
of writing into the internal flash ROM of an MCU.
Address-match breaks can be set only in RAM and ROM areas of an MCU.
Address-match breaks can be set at up to 8 points.
Address-match breaks can be set or canceled even when the user program is being executed.
When you use the address-match interrupt function in a user program, uncheck "Enable the Address Match
Interrupt Break Function" in the MCU tab of the Init dialog box of the emulator debugger. Thus, normal
software breaks are used for the internal RAM and ROM areas of an MCU.
Do not set a software break at an address where an address-match interrupt occurs. Otherwise, a user program
may be run out of control. Set a software or hardware break in the top address in address-match interrupt
processing.
When you single step an address where an address-match interrupt occurs, the program stops after executing the
first instruction after returning from address-match interrupt processing.
Software breaks change the instruction at a specified address to a BRK (00h). Therefore, take note that when
you reference the result of a trace in bus mode, "00h" is displayed.
As the BRK instruction is used for the emulator, do not use it in a user program.
You can neither set nor cancel a software breakpoint in the internal ROM area of an MCU during user program
execution, while you can set or cancel it in the internal RAM area of an MCU.
If the reset circuit of the user system has a watchdog timer function, disable it when using the emulator.
The protect is not canceled when bit 2 of protect register PRCR (PRC2), which enables writing into the port P9
direction register and the SI/Oi control register, is changed with the below procedure.
(1) Step execution of an instruction setting PRC2 to "1"
(2) Setting a break point between an instruction setting PRC2 to "1" and a point where the port P9 direction
(3) Setting PRC2 to "1" by the memory window or script window
register or the SI/Oi control register is set
IMPORTANT
4. Hardware Specifications
Page 96 of 108

Related parts for M3062PT3-CPE-4