C8051F206DK Silicon Laboratories Inc, C8051F206DK Datasheet - Page 129

DEV KIT FOR C8051F206

C8051F206DK

Manufacturer Part Number
C8051F206DK
Description
DEV KIT FOR C8051F206
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheets

Specifications of C8051F206DK

Contents
Evaluation Board, Power Supply, USB Cables, Adapter and Documentation
Processor To Be Evaluated
C8051F206
Interface Type
USB
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
Silicon Laboratories C8051F206
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1237
Bit7:
Bit6:
Bit5:
Bit4:
Bit3:
Bit2:
Bit1:
Bit0:
TF1
R/W
Bit7
TF1: Timer 1 Overflow Flag.
Set by hardware when Timer 1 overflows. This flag can be cleared by software but is auto-
matically cleared when the CPU vectors to the Timer 1 interrupt service routine.
0: No Timer 1 overflow detected.
1: Timer 1 has overflowed.
TR1: Timer 1 Run Control.
0: Timer 1 disabled.
1: Timer 1 enabled.
TF0: Timer 0 Overflow Flag.
Set by hardware when Timer 0 overflows. This flag can be cleared by software but is auto-
matically cleared when the CPU vectors to the Timer 0 interrupt service routine.
0: No Timer 0 overflow detected.
1: Timer 0 has overflowed.
TR0: Timer 0 Run Control.
0: Timer 0 disabled.
1: Timer 0 enabled.
IE1: External Interrupt 1.
This flag is set by hardware when an edge/level of type defined by IT1 is detected. It can be
cleared by software but is automatically cleared when the CPU vectors to the External Inter-
rupt 1 service routine if IT1 = 1. This flag is the inverse of the /INT1 input signal's logic level
when IT1 = 0.
IT1: Interrupt 1 Type Select.
This bit selects whether the configured /INT1 signal will detect falling edge or active-low
level-sensitive interrupts.
0: /INT1 is level triggered.
1: /INT1 is edge triggered.
IE0: External Interrupt 0.
This flag is set by hardware when an edge/level of type defined by IT0 is detected. It can be
cleared by software but is automatically cleared when the CPU vectors to the External Inter-
rupt 0 service routine if IT0 = 1. This flag is the inverse of the /INT0 input signal's logic level
when IT0 = 0.
IT0: Interrupt 0 Type Select.
This bit selects whether the configured /INT0 signal will detect falling edge or active-low
level-sensitive interrupts.
0: /INT0 is level triggered.
1: /INT0 is edge triggered.
TR1
R/W
Bit6
SFR Definition 17.1. TCON: Timer Control
TF0
R/W
Bit5
TR0
R/W
Bit4
Rev. 1.6
R/W
IE1
Bit3
R/W
IT1
Bit2
R/W
IE0
Bit1
C8051F2xx
R/W
IT0
Bit0
SFR Address:
Reset Value
00000000
0x88
129