DEMO9S08JS16 Freescale Semiconductor, DEMO9S08JS16 Datasheet - Page 4

BOARD DEMO FOR JS16 FAMILY

DEMO9S08JS16

Manufacturer Part Number
DEMO9S08JS16
Description
BOARD DEMO FOR JS16 FAMILY
Manufacturer
Freescale Semiconductor
Type
MCUr

Specifications of DEMO9S08JS16

Contents
2 Boards, Cable, Documentation, DVD
Processor To Be Evaluated
MC9S08JS16
Data Bus Width
8 bit
Interface Type
USB
Operating Supply Voltage
5 V
Silicon Manufacturer
Freescale
Core Architecture
HCS08
Core Sub-architecture
HCS08
Silicon Core Number
MC9S08
Silicon Family Name
S08JS
Rohs Compliant
Yes
For Use With/related Products
MC9S08JS16
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
CDC Serial Bridge
This lab demonstrates a bridge between CDC and a serial port (SCI). The CDC-Serial example
emulates a virtual serial port on the PC. The instructions below will guide you to program the
JS16 MCU, install the driver for the virtual serial port and communicate with a true serial port
using the two independent terminal windows.
1.
2.
3.
4.
5.
6.
7.
8.
9.
DEMO9S08JS16—Lab Tutorial
LAB
2
Open CodeWarrior for Microcontrollers. From the
Windows start menu, you can locate it using the path
“Programs>Freescale CodeWarrior>CW for Microcontroller
V6.2>CodeWarrior IDE.exe.”
From the CodeWarrior startup dialog, click “Start Using
CodeWarrior.”
Open the CDC-Serial example project by pressing “Ctrl”
+ “O” keys simultaneously. Follow C:\Program Files\
MC9S08JS16Demo\JS16_CDC_Serial and select
“JS16_CDC_Serial.mcp” and click “Open.”
Short 1&2, 3&4 of J4 with jumpers.
From the connection manager menu, select “DEMOJM on
USB1” port and click
“Connect (Reset).”
From the Erase and Program Flash menu, click “Yes” to
allow the debugger to mass erase the MCU’s on-chip flash
memory and program it with the new application.
Your computer will automatically recognize the JS16 as a
CDC device and begin the installation. Some interaction is
needed to install the USB driver. When prompted by
the computer to specify a location, select the
“MC9S08JS16CDC.inf” driver located
in C:\Program Files\MC9S08JS16Demo\JS16_CDC_Serial.
When hardware installation is
complete, the JS16 will be recognized as a CDC device with
an assigned virtual COM port.
With the board turned on and both cables
attached between host and board, compile and
program the JS16 MCU with CDC serial example
by clicking the button to launch the debugger.
Click the “Start/Continue (F5)” button in the
debugger to run the application. Close the
debugger.
10. Verify the virtual COM port assigned to your board in the
11. Launch two terminal window utilities. You can use either
12. In terminal window 1 (HyperTerminal), set the port
13. Set the baud rate to 9600.
14. Open COM port.
15. In terminal window 2 (P&E Micro Toolkit terminal window
16. Set the baud rate to 9600.
17. Click “Open Serial Port” button.
18. Type “Hello, Freescale!” or any other characters in CDC
19. Close COM port and terminal windows.
device manager under
“Port (COM and LTP).” In the following figure, the CDC-
serial virtual port has been
HyperTerminal or P&E Micro Toolkit terminal window for
CDC commands, however, P&E Micro Toolkit terminal
window must be used for UART commands. HyperTerminal
can be found under Start>Programs>Accessories>Com
munications and P&E Micro Toolkit terminal window can
be found under Start>Programs>P&E Embedded Multilink
Toolkit>Utilities.
assigned to your board per device manager.
utility), set port to
USB COM.
window utility and see them appear on UART window and
vice-versa.

Related parts for DEMO9S08JS16