SCA3100-D04 PCB VTI Technologies, SCA3100-D04 PCB Datasheet

EVAL BOARD ACCELEROMETER 3-AXIS

SCA3100-D04 PCB

Manufacturer Part Number
SCA3100-D04 PCB
Description
EVAL BOARD ACCELEROMETER 3-AXIS
Manufacturer
VTI Technologies
Datasheets

Specifications of SCA3100-D04 PCB

Sensor Type
Accelerometer, 3 Axis
Sensing Range
±2g
Interface
SPI
Sensitivity
900 counts/g
Voltage - Supply
3 V ~ 3.6 V
Embedded
No
Utilized Ic / Part
SCA3100-D04
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
551-1061
Doc.Nr. 8257300A.07
Product Family Specification
SCA3000 Series
3-axis accelerometer

Related parts for SCA3100-D04 PCB

SCA3100-D04 PCB Summary of contents

Page 1

Product Family Specification SCA3000 Series 3-axis accelerometer Doc.Nr. 8257300A.07 ...

Page 2

... Free-Fall Detection...................................................................................................................11 2.4.1 Description.........................................................................................................................11 2.4.2 Usage..................................................................................................................................11 2.4.3 Example..............................................................................................................................11 2.5 Ring Buffer ...............................................................................................................................12 2.5.1 Description.........................................................................................................................12 2.5.2 Usage..................................................................................................................................12 2.5.2.1 Overflow condition ....................................................................................................................12 2.5.3 Examples............................................................................................................................13 2.6 Temperature measurement.....................................................................................................13 2.6.1 Usage..................................................................................................................................13 2.7 Interrupt function (INT-pin) .....................................................................................................13 2.7.1 Usage..................................................................................................................................13 2.8 Clock .........................................................................................................................................14 VTI Technologies Oy www.vti.fi Doc.Nr. 8257300A.07 SCA3000 Series 2/ 43 Rev.A.07 ...

Page 3

... C AC characteristics .......................................................................................................31 6 Package Characteristics.................................................................................................. 31 6.1 Dimensions...............................................................................................................................31 7 Application information ................................................................................................... 32 7.1 Pin Description.........................................................................................................................32 7.2 Recommended circuit diagram ..............................................................................................32 7.3 Recommended PWB layout ....................................................................................................33 7.4 Assembly instructions ............................................................................................................35 7.5 Tape and reel specifications...................................................................................................35 8 Data sheet references ...................................................................................................... 36 VTI Technologies Oy www.vti.fi Doc.Nr. 8257300A.07 SCA3000 Series 3/ 43 Rev.A.07 ...

Page 4

... Sensitivity .................................................................................................................................37 8.2.1 Sensitivity calibration error..............................................................................................37 8.2.2 Sensitivity temperature error ...........................................................................................37 8.3 Linearity ....................................................................................................................................38 8.4 Noise .........................................................................................................................................39 8.5 Bandwidth.................................................................................................................................39 8.6 Cross-axis sensitivity ..............................................................................................................39 8.7 Turn-on time .............................................................................................................................40 9 Order Information............................................................................................................. 41 10 Document Change Control.............................................................................................. 42 11 Contact Information ......................................................................................................... 43 VTI Technologies Oy www.vti.fi Doc.Nr. 8257300A.07 SCA3000 Series 4/ 43 Rev.A.07 ...

Page 5

... The SCA3000 includes an internal oscillator, reference and non-volatile memory that enable the sensor's autonomous operation within a system. The temperature sensor is used in some product applications to enhance the temperature stability. In that case, temperature information can also be read out from the device. VTI Technologies Oy www.vti.fi Low-pass Decimation ...

Page 6

... Free-Fall Detection Free-Fall Detection (FFD) is intended to be used to save system resources. This feature activates the interrupt via the INT-pin when free-fall is detected. The minimum detectable distance depends on the individual product. Normal acceleration information is available when the FFD is enabled. VTI Technologies Oy www.vti.fi / SCA3000-E01 ...

Page 7

... The SCA3000 can also be set to optional measurement modes. See component specific data sheets for detailed functional parameters in all measurement modes. All available measurement modes for the SCA3000 are described in Table 2 below. VTI Technologies Oy www.vti.fi Doc.Nr. 8257300A.07 SCA3000 Series 2 C bus ...

Page 8

... Data overflow on negative acceleration x = ignore In case of overflow, the output register value must be discarded. When an overflow is detected, the bit pattern ‘0101 1111 1111 1xxx’ is used for positive accelerations and ‘1010 0000 0000 0xxx’ for VTI Technologies Oy www.vti.fi SCA3000-D01 SCA3000-E01 SCA3000-D02 SCA3000-E02 ...

Page 9

... BPF low-pass frequency …60 Hz and -3 dB high-pass frequency is 0.05 Hz …1 Hz. See Figure 2 below -10 -15 -20 0.01 Figure 2. The MD band-pass filter's frequency response. VTI Technologies Oy www.vti.fi SCA3000-D01 SCA3000-E01 SCA3000-D02 SCA3000-E02 - - 3072 3072 0110 0000 0000 0xxx 0110 0000 0000 0xxx 2303 ...

Page 10

... Write "01010000" (50h) into UNLOCK register 4. Write "10100000" (A0h) into UNLOCK register 5. Write "00000010" (02h) into CTRL_SEL register (to select indirect MD_CTRL register) 6. Write "00000011" (03h) into CTRL_DATA register (this data is written into MD_CTRL register, enable trigger on Y-channel, EN_Y = '1', enable trigger on X-channel, EN_X = '1') VTI Technologies Oy www.vti. ...

Page 11

... Example A simple example of free-fall detection usage: 1. Write "00010000" (10h) into the MODE register (enable free fall detection, FFD_EN = '1') 2. Acceleration data can be read normally 3. INT-pin is activated when free fall is detected, see section 2.7 for detailed INT-pin information. VTI Technologies Oy www.vti. ...

Page 12

... Acceleration data is available in X_LSB, X_MSB, Y_LSB, Y_MSB, Z_LSB and Z_MSB when the ring buffer is enabled. 2.5.2.1 Overflow condition Overflow is detected from data ring buffer in same way as from the output registers. See section 2.2.2.1 for details. VTI Technologies Oy www.vti.fi nd acceleration data will be stored Examples: Doc ...

Page 13

... INT_MASK register "1" results in interrupt when the register is 75% full. Setting BUF_H_EN bit in INT_MASK register "1" results in interrupt when the register is 50% full. Setting INT_ALL bit in INT_MASK register will mask all interrupts. VTI Technologies Oy www.vti.fi the output Ring Buffer is configured to sample only the Z-axis acceleration the SCA3000 is configured to give an interrupt when the output ring buffer − ...

Page 14

... If BUF_FULL bit is "1", Ring Buffer is 75% full. Correspondingly, if BUF_HALF is "1", the Ring Buffer is 50% full. See section 3.3 for INT_STATUS register details. 2.8 Clock The SCA3000 has an internal factory trimmed oscillator and clock generator. Internal frequencies vary product by product. VTI Technologies Oy www.vti.fi Doc.Nr. 8257300A.07 SCA3000 Series 14/ 43 Rev.A.07 ...

Page 15

... INT_STATUS 17h I2C_RD_SEL 18h CTRL_SEL 19h ... 1Dh 1Eh UNLOCK 1Fh ... 20h VTI Technologies Oy www.vti.fi Description ASIC revision ID number Reserved Status register Reserved X-axis LSB frame X-axis MSB frame Y-axis LSB frame Y-axis MSB frame Z-axis LSB frame Z-axis MSB frame ...

Page 16

... Register name: X_MSB, X-axis MSB frame Bits Mode 7:0 R Address: 06h Register name: Y_LSB, Y-axis LSB frame Bits Mode 7:0 R VTI Technologies Oy www.vti.fi Description HW interrupt mask register (configures the operation of INT-pin): - interrupt when output buffer is ¾ full (enable / disable) - interrupt when output buffer is ½ full ...

Page 17

... Bit number Acceleration [mg] SCA3000-E01,-E02 [X_LSB…Z_MSB] SCA3000-E01,-E02 Ring buffer in 11-bit mode [BUF_DATA] SCA3000-E01,-E02 Ring buffer in 8-bit mode [BUF_DATA sign bit x = not used bit VTI Technologies Oy www.vti.fi Initial Name Description Value 00h DATA Y-axis MSB frame Initial Name Description ...

Page 18

... Table 10. Temperature data is presented in unsigned format. The LSB bit (bit Table 10) weight is ~0.56°C. See section 2.6 for more detailed information of converting the data to temperature in [°C]. Table 10. Bit level description for temperature registers [TEMP_MSB … TEMP_LSB]. Register Bit number Bit in temperature register x = not used bit VTI Technologies Oy www.vti.fi MSB byte ...

Page 19

... R 3:0 R Address: 02h Register name: STATUS, status register Bits Mode 7 4 VTI Technologies Oy www.vti.fi Initial Name Description Value Count of available data samples in output ring buffer, 00h COUNT for more information see section 2.5.2. Initial Name Description Value 0 BUF_FULL Output ring buffer is ¾ full 1 – ...

Page 20

... Register name: CTRL_SEL, Control register selector, UNLOCK REQUIRED Bits Mode 7:5 RW 4:0 RW CTRL_SEL register works as an address pointer for registers listed below. When this register is written the content of selected register is available for reading/writing from/to register CTRL_DATA. VTI Technologies Oy www.vti.fi Initial Name Description Value 0 BUF_EN Output ring buffer 1 – ...

Page 21

... Table 11 ...Table 14 below. The threshold levels are in unsigned format and they are absolute values for the acceleration that triggers the motion detector interrupt. Values presented below are typical threshold values and they are not factory calibrated. VTI Technologies Oy www.vti.fi Name Description ...

Page 22

... MD_X_TH, MD_TH_Z SCA3000-E04 Acceleration [mg] MD_Y_TH x = not used bit Table 14. Bit level description for motion detector typical threshold levels (SCA3000-E05). Bit number SCA3000-E05 Acceleration [mg] MD_X_TH, MD_TH_Z SCA3000-E05 Acceleration [mg] MD_Y_TH x = not used bit VTI Technologies Oy www.vti.fi Typical bit weights 1300 650 x 1750 850 ...

Page 23

... RW 5 Address: 22h Register name: CTRL_DATA, Control register data, UNLOCK REQUIRED Bits Mode 7:0 RW VTI Technologies Oy www.vti.fi Name Description Reserved BUF_X_EN Store X-axis acceleration data to ring buffer 1 – enabled 0 – disabled BUF_Y_EN Store Y-axis acceleration data to ring buffer 1 – enabled 0 – disabled ...

Page 24

... Figure 6. SPI frame format. Each communication frame contains 16 bits. The first 8 bits in MOSI line contains info about the operation (read/write) and the register address being accessed. The first 6 bits define the 6 bit VTI Technologies Oy www.vti. (Phillips specification V2.1). However, only one per product is ...

Page 25

... X_LSB (X-axis LSB frame). The sensor replies to the requested operation by transferring the register content MSB first. Figure 7. An example of SPI read communication. VTI Technologies Oy www.vti.fi th bit is set to '0' to indicate the read operation. ...

Page 26

... The output ring buffer is addressed (register name BUF_DATA). The SCA3000 sensor continues shifting out the ring buffer content as long as µC continues supplying the SCK pulses. Figure 9. An example of output ring buffer read operation. VTI Technologies Oy www.vti.fi Doc.Nr. 8257300A.07 SCA3000 Series 26/ 43 Rev ...

Page 27

... This enables the burst read from output ring buffer (register BUF_DATA). 4.2.1.3 Decremented register read Decremented reading is possible only for registers X_LSB ... Z_MSB. Refer to decremented read with SPI interface section 4.1.3.2. VTI Technologies Oy www.vti. specification V2.1. Main used features of the device address is 0x1F1 ...

Page 28

... Start condition RS = Repeated start condition E = End condition SA = Slave Acknowledgement MA = Master Acknowledgement AA = Device address, 10 bits 2 Figure 10 frame format. VTI Technologies Oy www.vti.fi Read/write select bit (0=write, 1=read) register addr device addr 2nd byte SA 8 bits, MSB first AAAAAAAA device addr 2nd byte register addr ...

Page 29

... All the SCA3000 products have an internal level shifter that can be used to interface e.g. a micro controller using lower supply than the SCA3000. The level shifter is "programmed" by providing the supply voltage of the interfaced device to the DVIO-pin. Please refer to the corresponding product data sheet for details. VTI Technologies Oy www.vti.fi Value ) -0 ...

Page 30

... Terminal MISO, CSB 8 Time from CSB (10%) to stable MISO (10%, 90%) 9 Time from CSB (90%) to high impedance state of MISO1. Terminal MISO, SCK 10 Time from SCK (10%) to stable MISO (10%, 90%)1. VTI Technologies Oy www.vti. HOL MSB in DATA in T VAL2 MSB out DATA out ...

Page 31

... Please, see Phillips Semiconductors, The I 33. 6 Package Characteristics 6.1 Dimensions The package dimensions are presented in Figure 12 below (dimensions in millimeters [mm] with ±50 µm tolerance). Figure 12. SCA3000 package dimensions. VTI Technologies Oy www.vti. bus specification, Version 2.1, January 2000, pp. 31- Doc.Nr. 8257300A.07 SCA3000 Series 4 · ...

Page 32

... Xreset high. 6. INT-pin is used with output buffer as well as in Free Fall and Motion Detection mode. 7. Serial interface (SPI or I Recommended circuit diagram for the SCA3000 with SPI interface is presented in Figure 15 below. VTI Technologies Oy www.vti.fi SCA3000-D01, SCA3000-E01, SCA3000-E04 Not connected ...

Page 33

... AVDD and DVDD are routed on separate ways. 3. Use separate ground planes for AGND and DGND. Connect separate ground planes together on PWB. 4. Use double sided PWB, connect the bottom side plane to DGND. VTI Technologies Oy www.vti. interface is presented in Figure 16 below. Doc.Nr. 8257300A.07 ...

Page 34

... Figure 17. Recommended PWB pad layout for SCA3000. Recommended PWB layout for the SCA3000 with SPI interface is presented in Figure 18 below (circuit diagram presented in Figure 15 above). Figure 18. Recommended PWB layout for SCA3000 with SPI interface (not actual size, for reference only). VTI Technologies Oy www.vti.fi Doc.Nr. 8257300A.07 SCA3000 Series 34/ 43 ...

Page 35

... J-STD-020C. Please refer to the document "TN54 SCA3000 Assembly Instructions" for more detailed information of SCA3000 assembly. 7.5 Tape and reel specifications Please refer to the document "TN54 SCA3000 Assembly Instructions" for tape and reel specifications. VTI Technologies Oy www.vti. interface is presented in Figure 19 below (circuit Doc.Nr. 8257300A.07 ...

Page 36

... Offset − X axisTempEr @ where Output X-axisTempEr@T is sensor’s X-axis output reading [counts] in temperature T, Output [counts] at room temperature RT and Sens sensor’s nominal sensitivity [counts/g]. Sensor position for every measurement point. VTI Technologies Oy www.vti.fi Z-axis position Earth’s gravitation Y − Output Output − ...

Page 37

... Sensitivity temperature error is the difference between sensor’s sensitivity at different temperatures and the calibrated sensitivity. Error is calculated by Equation 6 Sens − Y axisTempEr @ T where Sens Y-axisTempEr@T is sensor’s measured Y-axis sensitivity [counts/g] at temperature T and Sens axis@T measured Y-axis sensitivity [counts/g] at room temperature RT. VTI Technologies Oy www.vti.fi Y-axis position Z Pin #1 − Output − + − − Y ...

Page 38

... Linearity error is calculated by Equation 7 = LinEr − Z axis @ acc where LinEr Z-axis@acc is sensor’s measured Z-axis output [counts] on input acceleration acc, Output VTI Technologies Oy www.vti.fi Centrifugal acceleration for Z-axis Pin #1 Acceleration reading from SCA3000 [g] acc +1 g Input acceleration [g] (centrifugal acceleration in parallel to SCA3000 measuring axis) ...

Page 39

... Cross-axis sensitivity Cross-axis sensitivity is sum of the alignment and the inherent sensitivity errors. Cross-axis sensitivity of one axis is a geometric sum of the sensitivities in two perpendicular directions. Cross-axis sensitivity [%] of X-axis is given by VTI Technologies Oy www.vti.fi (in Equation 7) is calculated from the straight line through @acc ...

Page 40

... XRESET is pulled high. The final value limits in turn-on time measurements is defined to be ± the sensor’s full scale measuring range (for example for SCA3000-D01 ±2g → g). Turn-on time definition for Z-axis is presented in Figure 25 below. Acceleration SCA3000 Z-axis output Turn on time Figure 25. Turn-on time definition for one axis. VTI Technologies Oy www.vti. ⋅ XZ ...

Page 41

... SCA3000-E02 PWB PWB assy, 3-Axis accelerometer with I2C interface, +/-3g SCA3000-E04 PWB PWB assy, 3-Axis accelerometer with SPI interface, +/-6g SCA3000-E05 PWB PWB assy, 3-Axis accelerometer with SPI interface, +/-18g SCA3000-D01DEMO SCA3000-D01 DEMOKIT VTI Technologies Oy www.vti.fi Doc.Nr. 8257300A.07 SCA3000 Series Packing Quantity T&R 100 T& ...

Page 42

... I2C communication added for SCA3000-L01 Corrections: typos, axis orientation A.06 30.10.2007 Corrected recommended PWB layouts. Removed references to D03 and L01. A.07 02.02.2009 VTI Technologies Oy www.vti. device address, sections "7.4 Solder paste and stencil parameters" and "7.5 Reflow" updated to "7.4 Assembly instructions" Doc.Nr. 8257300A.07 ...

Page 43

... Rennbahnstrasse 72-74 D-60528 Frankfurt am Main, Germany Tel. +49 69 6786 880 Fax +49 69 6786 8829 E-mail: sales.de@vti.fi China VTI Technologies Shanghai Office 6th floor, Room 618 780 Cailun Lu Pudong New Area 201203 Shanghai P.R. China Tel. +86 21 5132 0417 Fax +86 21 513 20 416 E-mail: sales ...

Related keywords