SCA111T VTI [VTI technologies], SCA111T Datasheet

no-image

SCA111T

Manufacturer Part Number
SCA111T
Description
Stand Alone Inclinometer
Manufacturer
VTI [VTI technologies]
Datasheet
Rev. 3 / 1 Nov 2005
Note 1
Note 2
Note 3
MEASURING DIRECTIONS
X-axis
Figure 1. Positions
Notes:
• It is important that the part is parallel to the mounting plane, and that the output equals the zero value when sensor is in zero position.
• Zero position: Please note the picture above which provides information on how the output of the accelerometer behaves in different
ELECTRICAL CHARACTERISTICS
Parameter
Supply voltage
Current consumption
Output load
PERFORMANCE CHARACTERISTICS
Parameter
Measuring range
Supply voltage
Measuring axis
Offset
Offset zero point error
Offset temperature error
Sensitivity
Sensitivity temperature error
Nonlinearity
Frequency response –3 dB
Cross-axis sensitivity
Typical values unless otherwise specifi ed.
circumstances when assembled. Please also note that you can rotate the part around the measuring plane for optimum mounting location.
Mounting position 1
(Horizontal)
Mounting position 2
(Vertical)
(2, 5
Deviation
The measuring range is limited by the sensitivity and offset.
Offset specifi ed as Output @ 0 °.
The frequency response is determined by the sensing element’s internal gas damping.
The output has true DC (0 Hz) response.
(1
(4
(5
(3
VTI Technologies reserves the right to modify this specifi cation without prior to notice.
(5
Negative incl.,
Condition
Unregulated or
regulated ratiometric
Resistive
Capacitive
Condition
(see “Directions”)
Output at 0 °
Max. deviation
0…70 °C
-25...85 °C
Sine of inclination
0…70 °C
-25...85 °C
Sinus output
Stand Alone Inclinometer
Zero position,
SCA111T-D02
SCA111T and SCA121T Series
Single or Dual Axis Analog Output
FEATURES
• Silicon 3D MEMS sensor
• 0,1 ° accuracy
• Resolution < 0,001 °
• Operating temperature range -40...+85 °C
• Long term stability < 0,02 °
• Shock resistance >20 000 g
• Sensing element -3 dB @ 18 Hz
• Main dimensions: 30x30x13 mm size, single or dual axis
• Voltage output
• RoHS compatible
Min.
4.75
-0.8 ...0.3
-1.5 ...0.5
10
7
7 ...35
±0.2
±0.6
±
2.5
70
0.1
18
X
3
30
1
Positive incl.
Typ
SCA121T-D03 SCA121T-D07
16
5
5
-0.8 ...0.3
-1.5 ...0.5
7 ...35
±
±0.2
±0.6
N/A
X-Y
2.5
35
18
3
90
1
Y-axis
Max.
5.25
35
20
Mounting position 1
Mounting position 2
Deviation
Note 4
Note 5
-0.8 ...0.3
-1.5 ...0.5
7 ...35
±0.2
±0.6
±
X-Y
2.5
Units
70
0.1
18
3
30
1
The cross-axis sensitivity determines how much inclination, perpendicular to the measuring
axis, couples to the output.
For optimum zero point accuracy, mounting angle of the part can be adjusted.
mA
kΩ
nF
V
V
Positive incl.,
Applies to: -D02, -D03, -D07
Applies to: -D04, -D05
For customised product please contact VTI Technologies
SCA111T-D04
-0.8 ...0.3
-1.5 ...0.5
5 ±0.25
±
±0.2
±0.6
N/A
2.5
35
18
X
3
90
1
BENEFITS
• Excellent long term stability
• Sensing element controlled frequency response
• Outstanding shock durability
• Harsh environment robustness
APPLICATIONS
• Platform tilt measurement
• Equipment and instrument condition monitoring
• Inclination based position measurement
• Rotational orientation measurement (dual axis)
Zero position,
SCA121T-D05
-0.8 ...0.3
-1.5 ...0.5
5
±0.2
±0.6
±
±0.25
N/A
X-Y
2.5
35
18
3
90
1
Negative incl.
mV/°(@offset pos.)
Units
%
%
Hz
%
°
V
V
°
°
°
°
Earth’s gravity

Related parts for SCA111T

SCA111T Summary of contents

Page 1

... Please also note that you can rotate the part around the measuring plane for optimum mounting location. Rev Nov 2005 VTI Technologies reserves the right to modify this specifi cation without prior to notice. SCA111T and SCA121T Series Single or Dual Axis Analog Output FEATURES • ...

Page 2

... FI-01621 Vantaa D-60528 Frankfurt am Main Finland Germany Tel. +358 9 879 181 Tel. +49 69 6786 880 Fax +358 9 879 18791 Fax +49 69 6786 8829 sales@vti.fi sales.de@vti.fi SCA111T and SCA121T Series SCA111T series Wire color Name Blue GND Red V cc Yellow ...

Related keywords