STEVAL-MKI064V1 STMicroelectronics, STEVAL-MKI064V1 Datasheet - Page 35

BOARD ADAPTER LSM303DLH DIL24

STEVAL-MKI064V1

Manufacturer Part Number
STEVAL-MKI064V1
Description
BOARD ADAPTER LSM303DLH DIL24
Manufacturer
STMicroelectronics
Series
MEMSr

Specifications of STEVAL-MKI064V1

Sensor Type
Accelerometer and Magnetometer
Sensing Range
±2g, 4g, 8g, ±1.3 ~ 8.1 gauss
Interface
I²C
Sensitivity
1 ~ 3.9 mg/Digit, ±0.01%/°C
Embedded
No
Utilized Ic / Part
LSM303DLH
Sensing Axis
Double Axis
Output Type
Digital
Interface Type
USB
For Use With
497-10682 - MOTEHRBOARD MEMS ADAPTER STM32
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Supply
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
LPR5xxxAL, LPY5xxxAL, LY5xxxAL
Other names
497-10689
LSM303DLH
9.1.12
INT1_CFG_A (30h)
Table 38.
Table 39.
Configuration register for Interrupt 1 source.
Table 40.
AOI
6D
ZHIE
ZLIE
YHIE
YLIE
XHIE
XLIE
AOI
AOI
0
0
1
1
INT1_CFG_A register
INT1_CFG_A description
Interrupt 1 source configurations
AND/OR combination of interrupt events. Default value: 0.
(See
6 direction detection function enable. Default value: 0.
(See
Enable interrupt generation on Z high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on Z low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
Enable interrupt generation on Y high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on Y low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
Enable interrupt generation on X high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on X low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
6D
Table
Table
40)
40)
ZHIE
6D
0
1
0
1
Doc ID 16941 Rev 1
ZLIE
YHIE
AND combination of interrupt events
OR combination of interrupt events
6 direction movement recognition
6 direction position recognition
Interrupt mode
YLIE
Registers description
XHIE
XLIE
35/47

Related parts for STEVAL-MKI064V1