EVL6566A-75WES4 STMicroelectronics, EVL6566A-75WES4 Datasheet - Page 33

BOARD DEMO FOR L6563/LL6566A

EVL6566A-75WES4

Manufacturer Part Number
EVL6566A-75WES4
Description
BOARD DEMO FOR L6563/LL6566A
Manufacturer
STMicroelectronics
Type
Power Factor Correctionr
Datasheets

Specifications of EVL6566A-75WES4

Main Purpose
AC/DC, Primary and Secondary Side with PFC
Outputs And Type
1, Isolated
Power - Output
75W
Voltage - Output
19V
Current - Output
4A
Voltage - Input
90 ~ 264VAC
Regulator Topology
Flyback
Board Type
Fully Populated
Utilized Ic / Part
L6563, L6566A, TSM1014
Input Voltage
90 V to 264 V
Output Voltage
19 V
Dimensions
78 mm x 170 mm
Product
Power Management Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Frequency - Switching
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
L6563S, L6566A
Other names
497-8834

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EVL6566A-75WES4
Manufacturer:
ST
0
L6563S
Application information
Figure 45. Interface circuits for power up sequencing when dc-dc has the SS
function
If this is not the case or it is not possible to achieve a start-up delay long enough (because
this prevents the dc-dc stage from starting up correctly) or, simply, the PWM controller is
devoid of soft start, the arrangement of
Figure 46
lets the dc-dc converter start-up when the
voltage generated by the PFC stage reaches a preset value. The technique relies on the
UVLO thresholds of the PWM controller.
Figure 46. Interface circuits for actual power-up sequencing (master PFC)
Another possible use of the RUN and PWM_STOP pins (again, in systems where the PFC
stage is the master) is the brownout protection, thanks to the hysteresis provided.
The brownout protection is basically a not-latched device shutdown function that is activated
when a condition of mains undervoltage is detected. This condition may cause overheating
of the primary power section due to an excess of RMS current. Brownout can also cause the
PFC pre-regulator to work open loop and this could be dangerous to the PFC stage itself
and the downstream converter, should the input voltage return abruptly to its rated value.
Another problem is the spurious restarts that may occur during converter power down and
that cause the output voltage of the converter not to decay to zero monotonically. For these
reasons it is usually preferable to shutdown the unit in case of brownout.
IC shutdown upon brownout can be easily realized as shown in
Figure 47
. The scheme on
the left is of general use, that one on the right can be used if the bias levels of the multiplier
and the R
·C
time constant are compatible with the specified brownout level and with the
FF
FF
specified holdup time respectively. In this latest case, an additional resistor voltage divider
and one capacitor are not needed.
Doc ID 16116 Rev 4
33/43

Related parts for EVL6566A-75WES4