DS26528DK Maxim Integrated Products, DS26528DK Datasheet - Page 120

no-image

DS26528DK

Manufacturer Part Number
DS26528DK
Description
KIT DESIGN FOR DS26528
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS26528DK

Main Purpose
Telecom, Framer and Line Interface Units (LIUs)
Utilized Ic / Part
G575DS26528
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Secondary Attributes
-
Embedded
-
Primary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
The GLISR register reports the LIU interrupt status for each of the eight T1/E1 LIUs. A logic one in the associated
bit location indicates a LIU has set its interrupt signal.
Bit 7: LIU Interrupt Status 8 (LIS8).
Bit 6: LIU Interrupt Status 7 (LIS7).
Bit 5: LIU Interrupt Status 6 (LIS6).
Bit 4: LIU Interrupt Status 5 (LIS5).
Bit 3: LIU Interrupt Status 4 (LIS4).
Bit 2: LIU Interrupt Status 3 (LIS3).
Bit 1: LIU Interrupt Status 2 (LIS2).
Bit 0: LIU Interrupt Status 1 (LIS1).
0 = LIU 8 has not issued an interrupt.
1 = LIU 8 has issued an interrupt.
0 = LIU 7 has not issued an interrupt.
1 = LIU 7 has issued an interrupt.
0 = LIU 6 has not issued an interrupt.
1 = LIU 6 has issued an interrupt.
0 = LIU 5 has not issued an interrupt.
1 = LIU 5 has issued an interrupt.
0 = LIU 4 has not issued an interrupt.
1 = LIU 4 has issued an interrupt.
0 = LIU 3 has not issued an interrupt.
1 = LIU 3 has issued an interrupt.
0 = LIU 2 has not issued an interrupt.
1 = LIU 2 has issued an interrupt.
0 = LIU 1 has not issued an interrupt.
1 = LIU 1 has issued an interrupt.
LIS8
7
0
GLISR
Global LIU Interrupt Status Register
0FBh
LIS7
6
0
LIS6
5
0
120 of 276
LIS5
4
0
LIS4
3
0
DS26528 Octal T1/E1/J1 Transceiver
LIS3
2
0
LIS2
1
0
LIS1
0
0