STEVAL-IHT001V1 STMicroelectronics, STEVAL-IHT001V1 Datasheet - Page 29

EVAL BOARD THERMO CONTROL REFRIG

STEVAL-IHT001V1

Manufacturer Part Number
STEVAL-IHT001V1
Description
EVAL BOARD THERMO CONTROL REFRIG
Manufacturer
STMicroelectronics
Datasheets

Specifications of STEVAL-IHT001V1

Design Resources
STEVAL-IHT001V1 Gerber Files STEVAL-IHT001V1 Schematic STEVAL-IHT001V1 Bill of Materials
Main Purpose
Reference Design, ARM7 Thermostat for Fridge or Freezer
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
ACS102-6, ACS110, ACST6, ST7LITE39F2
Primary Attributes
Compressor, Defrost & Light Controls
Secondary Attributes
Graphical User Interface
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-5514
UM0277
Appendix F
Table 6.
Evaporator temperature order 1
Evaporator temperature order 2
Evaporator temperature order 3
Evaporator temperature order
Compressor phase shift (T1)
Forced Compressor Control
Compressor running period
Gate current pulse width
Gate current pulse width
Temperature Hysteresis
Defrost Activation Delay
Evaporator temperature
(for defrost resistor, T2)
Forced Defrost Control
Compressor duty cycle
(for compressor, T3)
Forced Bulb Control
Forced Bulb Control
Compressor Status
Thermostat order
Light-bulb Status
Mains frequency
Defrost duration
Defrost Status
Parameter
ZVS delay
PC interface parameters description
PC interface parameters description
Software type
Input / Output
Input / Output
Input / Output
Input / Output
Input / Output
Input / Output
Input / Output
Input / Output
Input / Output
Input / Output
Input / Output
Output
Output
Output
Output
Output
Output
Output
Output
Input
Input
Input
Input
Minutes &
seconds
Hours &
Minutes
Minutes
LED for
LED for
LED for
Hour &
Green
Green
Green
Unit
N/A
N/A
N/A
N/A
N/A
ON
ON
ON
ms
ms
ms
Hz
°C
°C
µs
°C
°C
%
setting
Initial
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
-12
-20
0.5
50
20
-5
4
2
0
0
0
0
1
1
8
PC interface parameters description
00:01 to 04:30 (1’ to 4h30’)
00:10 to 30:00 (10” to 30’)
00:10’ to 24:00 (10’ to 24)
0 (OFF) or 1 (ON)
0 (OFF) or 1 (ON)
0 (OFF) or 1 (ON)
0 (OFF) or 1 (ON)
Allowed range
50 or 60 Hz
0.5 to 10°C
-50 to 10°C
-50 to 10°C
-50 to 10°C
40 to -50°C
40 to -50°C
0 to 100%
5 to 255
0.1 to 4
0.1 to 4
0.1 to 4
1 to 3
N/A
N/A
N/A
Setting
step
N/A
10”
0.1
0.5
0.5
0.5
0.1
0.1
0.1
10’
29/32
1
5
-
-
-
-