MCP3909RD-1PH1 Microchip Technology, MCP3909RD-1PH1 Datasheet - Page 11

BOARD DES MCP3909 ENERGY METER

MCP3909RD-1PH1

Manufacturer Part Number
MCP3909RD-1PH1
Description
BOARD DES MCP3909 ENERGY METER
Manufacturer
Microchip Technology

Specifications of MCP3909RD-1PH1

Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
MCP3909, PIC18F85J90
Primary Attributes
Single Phase Shunt Energy Meter
Secondary Attributes
16 Bit ADC
Ic Function
Single Phase Energy Measurement IC
Supply Voltage Range
4.5V To 5.5V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
SSOP
No. Of Pins
24
Interface Type
SPI
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
1.3
© 2009 Microchip Technology Inc.
GETTING STARTED
To describe how to use the MCP3909/PIC18F85J90 Single Phase Energy Meter
Reference Design, the following example is given using a 2-Wire 1-phase, 220V AC
line voltage and connections using an energy meter calibrator equipment or other
programmable load source. The meter design uses a 5A load for calibration current
and a maximum current (I
All connections described in this section are dependent on the choice of current
sensing element and a secondary external transformer may be required in higher
current meter designs.
For testing a calibrated meter, the following connections apply for a 4-wire connection.
1.3.1
FIGURE 1-3:
1.3.2
The meter will turn on when the line connection has 220V connected. The LCD display
will show total energy accumulated.
Line
Neutral
MAIN
Step 1: Wiring connections
Step 2: Turn On Line/Load Power to the Meter (Power the Meter)
1
Example Connections using a 4-Wire System.
MAX
) of 10A.
2
3
Product Overview
4
DS51884A-page 11
Neutral
LOAD
Line

Related parts for MCP3909RD-1PH1