SI5356-EVB Silicon Laboratories Inc, SI5356-EVB Datasheet

EVALUATION BOARD FOR SI5356

SI5356-EVB

Manufacturer Part Number
SI5356-EVB
Description
EVALUATION BOARD FOR SI5356
Manufacturer
Silicon Laboratories Inc
Datasheets

Specifications of SI5356-EVB

Main Purpose
Timing, Clock Generator
Utilized Ic / Part
SI5356
Technology Type
Evaluation Board
For Use With/related Products
Si5356
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Secondary Attributes
-
Embedded
-
Primary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1750
Si5356 E
Description
The Si5356 evaluation board (EVB) is used for
evaluating
frequency 1–200 MHz, quad frequency 8-output clock
generator.
Rev. 0.2 6/10
the
Si5356
VALUATION
I
2
C
programmable,
Figure 1. Si5356 Evaluation Board
Copyright © 2010 by Silicon Labs
B
OARD
any
EVB Features
U
Fully powered from a single USB port
On-board 25 MHz XTAL allows standalone
asynchronous operation
GUI programmable V
operate from 3.3 V, 2.5 V, or 1.8 V (core)
GUI programmable V
the four banks of outputs to have its own supply
voltage selectable from 3.3 V, 2.5 V, and 1.8 V
GUI controlled voltage, current, and power
measurements of V
Voltage supply jumpers allows easy access for use
of external supplies or current measurements.
SER
S
Si5356- EVB
G
U I D E
DD
DD
DDO
and all four V
supply allows device to
supplies allows each of
DDO
supplies.
Si5356-EVB

Related parts for SI5356-EVB

SI5356-EVB Summary of contents

Page 1

... GUI controlled voltage, current, and power measurements of V  Voltage supply jumpers allows easy access for use of external supplies or current measurements. Figure 1. Si5356 Evaluation Board Copyright © 2010 by Silicon Labs Si5356- EVB supply allows device to DD supplies allows each of DDO and all four V supplies. DD DDO Si5356-EVB ...

Page 2

... Si5356-EVB 1. Quick Start 1. Install the Si5356 ClockBuilder™ Desktop Software and driver. (Assumes that Microsoft .NET Framework 1.1 is already installed.) 2. Connect a USB cable from the EVB to the PC where the software was installed. 3. Leave the jumpers as installed from the factory and launch the Si5356 configuration software by clicking on Start  ...

Page 3

... GUI will identify the event that caused the interrupt to happen. 2.2. Inputs The Si5356 EVB provides two reference options - using the on-board XTAL or an external reference. Note: Si5356-EVB Rev 1.0 does not support synchronous operation using the CLKIN input. This feature will be supported in future revisions. 2.2.1. External Input reference An SMA connector (CLKIN) is provided to receive an external single-ended CMOS signal ...

Page 4

... Si5356-EVB 3. ClockBuilder Desktop Software Installation The following sections describe how to install and begin using the software. There is also a readme.txt file with the installation files as well as a user guide installed with the software. 3.1. System Requirements  Microsoft Windows 2000 or Windows XP  ...

Page 5

... Close all the programs and help files before running the uninstaller to ensure complete removal of the software. The driver software must be uninstalled separately. See “3.6. USBXpress Driver Installation” for details. To uninstall the software, use the Add and Remove Programs utility in the Control Panel, as shown in Figure 3. Figure 3. Uninstall in Add and Remove Programs Si5356-EVB Rev. 0.2 5 ...

Page 6

... Si5356-EVB 3.5. ClockBuilder Desktop Software Description There are several programs to control the Si5356 device. These are available by clicking Start Programs Silicon Laboratories ClockBuilder Desktop Software X.X, where X.X is the software version number. There is a detailed user guide accessible here and in the Help  Help Menu option of the software ...

Page 7

... Figure 6. Successful Driver Installation Rev. 0.2 Si5356-EVB 7 ...

Page 8

... Si5356-EVB The USBXpress driver may be removed via the Add and Remove Programs utility in the Control Panel. Locate the entry called Silicon Laboratories USBXpress Device. Click the button, and it should show the version and location of what it will remove. The USBXpress installation files are located with the ClockBuilder Desktop Software. The driver files for the EVB may be reinstalled from this location or by running the install software ...

Page 9

... Si5356-EVB Schematics VDDOD 11 VDDOC 15 VDDOB EPAD 16 25 VDDOA 20 GND 23 VDD 24 VDD 7 Rev. 0.2 Si5356-EVB 9 ...

Page 10

... Si5356-EVB VBUS 12 REGIN 11 VDD 10 GND 2 10 GND 7 VDD 13 VDD Rev. 0.2 GND 14 GND 14 ...

Page 11

... VLOGIC 10 GND 8 VSS 18 VDD 7 VLOGIC 10 GND 8 VSS 18 VDD 7 Rev. 0.2 Si5356-EVB VLOGIC 10 GND 8 VSS 18 VDD 7 11 ...

Page 12

... R1 4.99 k R2,R3,R4,R5, R6,R8,R9,R10, R11,R12,R13, R14,R18,R19, R22,R23,R34, R35,R37 18 1 R15 10 k R16,R17 2.21 k 12 Table 2. Si5356-EVB Bill of Materials Voltage Tol PCB Footprint 10 V ±10% C0402 10 V ±20% C1206 25 V ±10% C1206 25 V ±20% 6032_EIAC 10 V ±10% C0603 10 V ±20% ...

Page 13

... Table 2. Si5356-EVB Bill of Materials (Continued) Item Qty Reference Value 20 2 R20,R21 1 k R24,R25,R45, 1.02 k R46 22 7 R26,R27,R28, 1 k R39,R40,R41, R42 23 4 R29,R30,R31, 2 k R33 220  R43,R44 412  R47 10  R48,R49,R50, R51,R54 27 4 R52,R53,R55, 10 k ...

Page 14

... Si5356-EVB Table 2. Si5356-EVB Bill of Materials (Continued) Item Qty Reference Value SMA TP1,TP2,TP3, RED TP5,TP6,TP7, TP8,TP9,TP10, TP11,TP12, TP13,TP14 14 Voltage Tol PCB Footprint SMA-EDGE-5 0 R0402 TESTPOINT Rev. 0.2 Mfr Mfr Part Number Johnson 142-0701-801 Components Venkel CR0402-16W-000 Kobiconn 151-207-RC ...

Page 15

OCUMENT HANGE IST Revision 0.1 to Revision 0.2  Changed “Any Rate Clock Generator” to “ClockBuilder Desktop” throughout.  Changed “MultiSynth Clock Programmer” to “ClockBuilder Desktop” throughout.  Updated Figure 3 on page 5.  Removed “Uninstaller ...

Page 16

... Si5356-EVB C I ONTACT NFORMATION Silicon Laboratories Inc. 400 West Cesar Chavez Austin, TX 78701 Tel: 1+(512) 416-8500 Fax: 1+(512) 416-9669 Toll Free: 1+(877) 444-3032 Please visit the Silicon Labs Technical Support web page: https://www.silabs.com/support/pages/contacttechnicalsupport.aspx and register to submit a technical support request. The information in this document is believed to be accurate in all respects at the time of publication but is subject to change without notice. ...