S8T-BUS02 Omron, S8T-BUS02 Datasheet - Page 2

CONNECTOR AC BUS LINE

S8T-BUS02

Manufacturer Part Number
S8T-BUS02
Description
CONNECTOR AC BUS LINE
Manufacturer
Omron
Series
S8TSr
Datasheet

Specifications of S8T-BUS02

Accessory Type
Bus Line Connectors
Mounting Type
Din Rail
Output 1 Vdc +
0VDC
Product
Switching
Mounting Style
PCB
For Use With
S8TS Model Power Supplies
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
S8TS Power Supplies
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S8TBUS02
Specifications
■ Ratings/Characteristics
12/24-V Models (Basic Block: S8TS-06024@/S8TS-03012@)
Note: 1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal
Efficiency (TYP.)
Input
Output
(See note
4.)
Additional
functions
Other
2. Refer to page 7 for details on adjusting the output voltage for parallel operation. If set to less than −10%, the undervoltage detection function may
3. Class 2 approval does not apply to parallel operation.
4. The output current is specified at power output terminals.
5. Refer to the Engineering Data on page 8 for details.
6. To reset the protection, turn OFF the input power for one minute or longer and then turn it back again.
7. Be sure to mount End Plates (PFP-M) on both ends of the Power Supply.
temperature of the Power Supply may result in ignition or burning.
operate. Ensure that the output capacity and output current after adjustment do not exceed the rated output capacity and rated output current
respectively. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than 10% of the voltage adjustment range (28 V
min. for 24-V models). When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is
not damaged.
Voltage (See note 1.)
Frequency (See note 1.)
Current
Power factor
Harmonic current emissions
Leakage current 100 V input
Inrush current
(See note 5.)
Voltage adjustment range
Ripple
Input variation influence
Load variation influence
Temperature variation influence
Startup time
Hold time (See note 5.)
Overload protection (See note 5.)
Overvoltage protection (See notes 5
and 6.)
Parallel operation
N+1 redundant system
Series operation
Undervoltage indicator (See note 5.)
Undervoltage detection output (See
note 5.)
Ambient operating temperature (See
note 5.)
Storage temperature
Ambient operating humidity
Dielectric strength
Insulation resistance
Vibration resistance (See note 7.)
Shock resistance (See note 7.)
Output indicator
EMI
EMS
Approved
standards
Weight
Item
100 V input
200 V input
240 V input
100 V input
200 V input
Conducted Emission Conforms to EN61204-3 EN55011 Class B and based on FCC Class A
Radiated Emission
UL:
cUL:
cUR:
EN/VDE:
24-V models: 75% min.; 12-V models: 70% min. (with rated input, 100% load)
100 to 240 VAC (85 to 264 VAC)
50/60 Hz (47 to 63 Hz)
24-V models: 1.0 A max.
12-V models: 0.7 A max.
24-V models: 0.5 A max.
12-V models: 0.4 A max.
24-V models: 0.9 min.; 12-V models: 0.8 min. (with rated input, 100% load)
Conforms to EN61000-3-2
0.35 mA max.
0.7 mA max.
25 A max. (for a cold start at 25°C)
50 A max. (for a cold start at 25°C)
24-V models: 22 to 28 V
12-V models: 12 V ±10% (with V.ADJ) (See note 2.)
2% (p-p) max.
0.5% max. (with 85 to 264 VAC input, 100% load)
2% max. (with rated input, 10% to 100% load)
0.05%/°C max. (with rated input and output)
1,000 ms max.
20 ms min. (with 100/200 VAC, rated input)
105% to 125% of rated load current, voltage drop,
automatic reset
Yes
Yes (Up to 4 Blocks)
Yes (Up to 5 Blocks)
Yes
Yes (color: red)
Yes (open collector output), 30 VDC max., 50 mA max.
Refer to the derating curve in Engineering Data (with no icing or condensation).
−25 to 65°C
25% to 85% (Storage humidity: 25% to 90%)
3.0 kVAC for 1 minute (between all inputs and all outputs; detection current: 20 mA)
2.0 kVAC for 1 minute (between all inputs and PE terminal; detection current: 20 mA)
1.0 kVAC for 1 minute (between all outputs and PE terminal; detection current: 20 mA)
100 MΩ min. (between all outputs, and all inputs/PE terminal) at 500 VDC
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
150 m/s
Yes (color: green)
Conforms to EN61204-3 EN55011 Class B
Conforms to EN61204-3 High severity levels
UL508 (Listing; Class 2: Per UL1310) (See note 3.), UL60950-1, UL1604 (Listing; Class I/Division 2, Groups A,
B, C, D, Hazardous Locations)
CSA C22.2 No.14 (Class 2: Per No.223) (See note 3.), No.213 (Class I/Division 2, Groups A, B, C, D, Hazardous
Locations)
No. 60950-1
EN50178 (=VDE0160)
450 g max.
2
, 3 times each in ±X, ±Y, and ±Z directions
Single operation
24-V models: 1.0 A × (No. of Blocks) max.
12-V models: 0.7 A × (No. of Blocks) max.
24-V models: 0.5 A × (No. of Blocks) max.
12-V models: 0.4 A × (No. of Blocks) max.
0.35 mA × (No. of Blocks) max.
0.7 mA × (No. of Blocks) max.
25 A × (No. of Blocks) max. (for a cold start at 25°C)
50 A × (No. of Blocks) max. (for a cold start at 25°C)
3% max. (with rated input, 10% to 100% load)
100% to 125% of rated load current, voltage drop, au-
tomatic reset
450 g × (No. of Blocks) max.
Parallel operation
S8TS
2

Related parts for S8T-BUS02