S82Y-VS10F Omron, S82Y-VS10F Datasheet - Page 5

no-image

S82Y-VS10F

Manufacturer Part Number
S82Y-VS10F
Description
MOUNTING BRACKT FRONT FOR S8VM
Manufacturer
Omron
Series
S8VSr
Datasheets

Specifications of S82Y-VS10F

Accessory Type
Mounting Bracket(s)
For Use With/related Products
S8VS 60W, 90W, 120W Power Supplies
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
S82YVS10F
*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in
*2. For a cold start at 25°C. Refer to Engineering Data (60-W, 90-W, 120-W, 180-W, 240-W, and 480-W Models) on page 24 for details.
*3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage adjustment range (by more than +10% for 240-W models with indication monitor).
*4. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON.
*5. Displayed on 7-segment LED. (character height: 8 mm)
*6. Resolution of output voltage indication: 0.1 V, Precision of output voltage indication: ±2% (percentage of output voltage value, ±1 digit)
*7. Resolution of output current indication: 0.1 A; Precision of output current indication: ±5% F.S. ±1 digit max. (specified by rated output voltage)
*8. Resolution of peak-hold current indication: 0.1 A; Precision of peak-hold current indication: ±5% F.S. ±1 digit max. (specified by rated output voltage);
*9. A Type and B Type: Sinking, AP Type and BP Type: Sourcing, BE Type: No alarm output.
*10. S8VS-06024A, S8VS-09024A/AP, S8VS-12024A/AP, S8VS-18024A/AP, and S8VS-24024A/AP only
*11. DC input is possible only with BE models (allowable range: 80 to 370 VDC). The applicable range for EC Directives and other safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264
*12. The standard 60-W, 90-W, 120-W, 180-W, and 240-W models and all 480-W models conform to EN 60950-1.
Item
Efficiency (typical) (rated input voltage)
Input
Output
Additional
functions
Other
ignition or burning.
When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
Signal width required for peak-hold current: 20 ms
VAC).
Voltage *1
Frequency *1
Current
Power factor
Harmonic current regulation
Leakage current
Inrush current *2
Voltage adjustment range *3
Ripple
Input variation influence
Load variation influence (rated input voltage) 1.5% max. (with rated input, 0 to 100% load)
Temperature variation influence
Startup time *2
Hold time *2
Overload protection *2
Overvoltage protection *2, *4
Output voltage indication *5
Output current indication *5
Peak-hold current indication *5
Maintenance forecast monitor indication *5
Maintenance forecast monitor output
Total run time monitor indication *5
Total run time monitor output *5
Undervoltage alarm indication *5
Undervoltage alarm output terminals
Parallel operation
Series operation
Operating ambient temperature
Storage temperature
Operating ambient humidity
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
Output indicator
EMI
EMS
Approved standards *11
SEMI *11
Weight
With 100-VAC input 1.7 A max.
With 200-VAC input 1.0 A max.
With 100-VAC input 0.5 mA max.
With 200-VAC input 1.0 mA max.
With 100-VAC input 25 A max. (17.5 A max. for BE models)
With 200-VAC input 50 A max. (35 A max. for BE models)
Conducted
Emissions
Radiated
Emissions
Power ratings
Type
Standard
78% min.
100 to 240 VAC (allowable range 85 to 264 VAC *1)
50/60 Hz (47 to 450 Hz)
---
Conforms to EN61000-3-2
−10% to 15% (with V. ADJ)
2.0% (p-p) max. (at rated input/output voltage)
0.5% max. (at 85- to 264-VAC input, 100% load)
0.05%/°C max.
1,000 ms max. (at rated input/output voltage)
20 ms min. (at rated input/output voltage)
105% to 160% of rated load current, inverted L voltage drop, intermittent, automatic reset
Yes
No
No
No
No
No
No
No
No
No
No
Yes for up to 2 Power Supplies (with external diode)
Refer to the derating curve in Engineering Data (60-W, 90-W, 120-W, 180-W, 240-W, and 480-W Models). (with no icing or
condensation)
−25 to 65°C
25% to 85% (Storage humidity: 25% to 90%)
3.0 kVAC for 1 min. (between all inputs and outputs/ alarm outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs/ alarm outputs and PE terminals; detection current for standard models: 30 mA,
detection current for models with indication monitor: 20 mA)
500 VAC for 1 min. (between all outputs and alarm outputs; detection current: 20 mA)
100 MΩ min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 VDC
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
10 to 150 Hz, 0.35-mm single amplitude (5 G max.) for 80 min each in X, Y, and Z directions
150 m/s
Yes (color: green)
Models with indication monitor: Conforms to EN61204-3 EN55011 Class A and based on FCC Class A, Conforms to EN61204-
3 EN55011 Class B *11
Standard models: Conforms to EN61204-3 EN55011 Group 1 Class B and based on FCC Class A
Models with indication monitor: Conforms to EN61204-3 EN55011 Class A, Conforms to EN61204-3 EN55011 Class B *11
Standard models: Conforms to EN61204-3 EN55011 Group 1 Class B
Conforms to EN61204-3 high severity levels
UL: UL508 (Listing; Class 2 Output: Per UL1310),
UL60950-1
cUL: CSA C22.2 No.107.1 (Class 2 Output: Per
CSA C22.2 No. 223)
cUR: CSA C22.2 No.60950-1
EN/VDE: EN50178 (= VDE0160), EN60950-1
(= VDE0805 Teil 1) *12
KOSHA S Mark *10
F47-0706 (With 200-VAC input)
330 g max.
2
, 3 times each in ±X, ±Y, and ±Z directions
Yes (selectable) *6
Yes (selectable) *7
Yes (selectable) *8
Yes (selectable)
Yes (selectable)
forecast monitor
Maintenance
60 W
No
Yes (selectable)
Total run time
monitor
80% min.
2.3 A max.
1.4 A max.
No
No
No
No
No
No
UL: UL508 (Listing), UL60950-1
UL for S8VS-09024S-@@@S-@ only: UL508 (Listing, Class 2 Output: Per
UL1310), UL60950-1
cUL: CSA C22.2 No.107.1
cUL for S8VS-09024S-@@@S-@ only: CSA C22.2 No.107.1 (Class 2
Output: Per CSA C22.2 No. 223)
cUR: CSA C22.2 No.60950-1
EN/VDE: EN50178 (= VDE0160),
EN60950-1 (SELV) (= VDE0805 Teil 1) *12
KOSHA S Mark *10
490 g max.
Standard
The voltage cannot be adjusted for the S8VS-09024S-@.
Yes (selectable) *6
Yes (selectable) *7
Yes (selectable) *8
Yes (selectable)
Yes (transistor output),
30 VDC max., 50 mA max. *9
Yes (selectable)
Yes (transistor output), 30 VDC max., 50 mA max. *9
Maintenance forecast
monitor
90 W
No
No
Yes (selectable)
Yes (transistor output),
30 VDC max., 50 mA max. *9
Total run time monitor
S8VS
5