S82Y-VS10F Omron, S82Y-VS10F Datasheet - Page 16

no-image

S82Y-VS10F

Manufacturer Part Number
S82Y-VS10F
Description
MOUNTING BRACKT FRONT FOR S8VM
Manufacturer
Omron
Series
S8VSr
Datasheets

Specifications of S82Y-VS10F

Accessory Type
Mounting Bracket(s)
For Use With/related Products
S8VS 60W, 90W, 120W Power Supplies
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
S82YVS10F
Construction and Nomenclature
Nomenclature
60-W Models
Standard Model
S8VS-06024
90-W/120-W Models
Standard Models
S8VS-09024/S8VS-0924S/
S8VS-12024
180-W Models
Standard Model
S8VS-18024
240-W Models
Standard Model
S8VS-24024
* The terminal arrangement is the same for models with screwless
terminal blocks and standard models.
1
1
1
1
3
3
3
3
2
2
4
5
2
4
5
2
4
5
4
5
Note: The S8VS-12024A is shown above.
Note: The S8VS-24024A is shown above.
Models with Indication Monitor
S8VS-06024@
Note: The S8VS-06024A is shown above.
Models with Indication Monitor
S8VS-09024@@@/
S8VS-09024@@@S/S8VS-12024@@@
Models with Indication Monitor
S8VS-18024@@@
Note: The S8VS-18024A is shown above.
Models with Indication Monitor
S8VS-24024@@@
10
12
1
6
10
12
12
10
6
1
1
6
1
6
11
13
11 13
11
3
13
3
3
3
3
2
2
7
8
4
5
2
7
8
9
4
5
7
8
9
4
2
5
(60-W, 90-W, 120-W, 180-W, 240-W, and 480-W Models)
7
8
9
4
5
*1. The fuse is located on the (L) side. For a DC input, connect the
*2. This is the protective earth terminal specified in the safety
*3. The output voltage cannot be adjusted for the
*4. S8VS-@@@24A@@/B@@/BE@ only.
*5. S8VS-@@@24A@@/B@@ only (except the S8VS-06024@).
*6. Both sinking and sourcing outputs are available.
*7. S8VS-@@@24A@@ only (excluding S8VS-06024A).
*8. S8VS-@@@24B@@ only (excluding S8VS-06024B).
No.
10 Down Key *5
11
12
13
1
2
3
4
5
6
7
8
9
positive voltage to the L terminal.
standards. Always ground this terminal.
S8VS-09024@@@S.
AC Input terminals
(L), (N)
Protective Earth
terminal (PE)
DC Output terminals
(−V), (+V)
Output indicator
(DC ON: Green)
Output voltage
adjuster (V.ADJ)
Main display (Red) *4
Operation
indicator
(Orange) *4
Mode Key *4
Up Key *5
Alarm
outputs
*5, *6
Name
Undervoltage
output
terminal (DC
Low)
Maintenance
Forecast
output
terminal (Yrs)
*7
Total run time
output
terminal (kh)
*8
Common
terminal
V
A
Apk
Yrs
kh
Connect the input lines to these
terminals. *1
Connect the ground line to this
terminal. *2
Connect the load lines to these
terminals.
Lights while a direct current (DC)
output is ON.
Use to adjust the voltage. *3
Indicates the measurement or set
value.
Lights up when the output voltage is
indicated. Blinks during setup of
undervoltage alarm value.
Lights up during indication of output
current.
Lights up during indication of peak
hold current.
Lights up during indication of
maintenance forecast monitor.
Blinks during setup of maintenance
forecast monitor setting. (S8VS-
@@@24A@@)
Lights up during indication of total
run time monitor. Blinks during setup
of total run time monitor. (S8VS-
@@@24B@@)
Use the Mode Key to change the
indicated parameter or reset the
peak hold current value.
Use the Up Key to change to the
setting mode or to increase the set
value.
Use the Down Key to change to the
setting mode or to decrease the set
value.
Output when a drop is detected in
the output voltage (voltage drop =
transistor OFF).
Output when the set value for
maintenance is reached (transistor
OFF).
Output when the set value for total
run time is reached (transistor OFF).
Common terminal (emitter) for
terminals 11 and 12.
Function
S8VS
16