S82Y-D60S Omron, S82Y-D60S Datasheet
S82Y-D60S
Specifications of S82Y-D60S
Related parts for S82Y-D60S
S82Y-D60S Summary of contents
Page 1
Switching Power Supply S82D High-Grade Power Supply for Demanding Industrial Applications Wide range of output voltages Selectable 85 to 132 VAC or D 170 to 264 VAC input voltage. Equipped with overvoltage and overload ...
Page 2
... Relay output, connector SPST, 250 VAC load resistance, but switching capacity is 125 VA Yes Yes Yes (This table continues on the next page.) S82D Part number S82Y-D30B S82Y-D60B S82Y-D30S S82Y-D60S S82Y-D60T S82Y-D30A S82Y-D60A S82Y-DFAN S82Y-DFAN 600 max max typ typ. ...
Page 3
Specifications Table – continued from previous page Power rating Characteristics Ambient temperature Ambient temperature Operating Storage Ambient humidity Ambient humidity Operating Storage Dielectric strength (see note below table) Insulation resistance (see note below table) Vibration resistance Shock resistance Output indicator ...
Page 4
J OVERLOAD PROTECTION The protective function prevents damage to the load as well as to the power supply itself due to overload. If the load current rises above the overload set value (105% to 135% of the rated load current), ...
Page 5
Nomenclature Output Terminals: Connect load wiring. 2. Input Terminals: Connect input wiring. 3. Voltage Select Terminals: Switch the input ...
Page 6
Operation J REMOTE SENSING FUNCTION This function corrects a voltage drop in the load wiring. When using the remote sensing function, remove the short bars from the remote sensing terminals as shown in the following diagram. Remote sensing connection (2-wire ...
Page 7
J SWITCHING THE INPUT VOLTAGE BETWEEN 120 V AND 240 V • Select 100 to 120 or 200 to 240 V input voltage by shorting or opening the input voltage switching terminals, as shown in the diagram below. (Factory set ...
Page 8
... Power supply Connection kit S82D-300 W S82Y-D30A S82D-600 W S82Y-D60A Wiring Specifications When using lead wires, the wires should meet the specifications in the following table. Model Cross sectional area 2 S82D-3005 14 mm min ...
Page 9
Dimensions Unit: mm (inch) J SWITCHING POWER SUPPLIES S82D-30jj (300 W) M3 terminal screw 92 (3.62) M4 terminal screw S82D-60jj (600 W) 190 (7.48) 92 (3.62) M4 terminal screw 30 max. 4 max. 120 190 (7.48) (4.72) M5 terminal Eight, ...
Page 10
... Unit: mm (inch) J MOUNTING BRACKETS (ORDER SEPARATELY) Bottom Mounting S82Y-D30B for S82D-30jj (5.91) S82Y-D60B for S82D-60jj Side Mounting S82Y-D30S for S82D-30jj 15 32 122 (4.80) 55 S82Y-D60S for S82D-60jj 122 (4.80 Switching Power Supply 190 (7.48) 160 150 138 100 Four, 4.5-dia holes Four, 4.5-dia. holes countersunk at 90_ 200 (7 ...
Page 11
... J REPLACING THE FAN Fan Alarm • necessary to replace the internal fan when the fan alarm output goes ON. Note: Replacement fan S82Y-DFAN can be ordered through your dealer. • To replace the fan, remove the back cover as shown in the diagram below. Connector for ...
Page 12
... Seller hereby objects to any terms or conditions proposed in Buyer’s purchase order or other documents which are inconsistent with addi- tion to, these Terms. Please contact your Omron representative to confirm any additional terms for sales from your Omron company. 2. Prices. All prices stated are current, subject to change without notice by Seller ...
Page 13
S82D Switching Power Supply 13 ...