DS1200-3-002 Emerson Network Power, DS1200-3-002 Datasheet - Page 2

no-image

DS1200-3-002

Manufacturer Part Number
DS1200-3-002
Description
POWER SUPPLY AC/DC 12V 1200W
Manufacturer
Emerson Network Power
Series
DS1200r
Datasheets

Specifications of DS1200-3-002

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
1200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
180 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 100A
Size / Dimension
11" L x 3.2" W x 1.57" H (279.4mm x 81.3mm x 39.9mm)
Power (watts) - Rated
1200W
Operating Temperature
-10°C ~ 50°C
Efficiency
91%
Approvals
CB, CE, cUL, EN, NEMKO, UL
Line Regulation
±5%
Load Regulation
±5%
Input Voltage
90 to 264V
Output Voltage
12V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1271
Environmental Specifications
Logic Control
Ordering Information
*Over current latches off if overcurrent lasts over 1 seconds, otherwise it is auto recovery.
**Release in April 2010
† Derating may apply.
Operating temperature:
Storage temperature:
Altitude, operating:
Electromagnetic susceptibility / Input transients:
RoHS & lead-free compliant:
Humidity:
Shock and vibration specificatons:
MTBF (Demonstrated):
PS_SEATED (A4):
PWR GOOD (C3):
AC OK (B1):
PS_INHIBIT/PS_KILL (B4):
PS ON (A1):
DS1200-3-003**
DS1200-3-004**
Model Number
DS1200-3-002
1400
1200
1000
800
600
400
200
DS1200-3
0
0
5
10
Voltage Set Point
Nominal Output
15
12.0 Vdc
12.0 Vdc
12.0 Vdc
12.0 Vdc
20
25
STANDARD AIR DERATING
TTL logic LOW if power supply is seated into system connector. This is a short pin. A logic HIGH if
the PSU is removed
A low logic level if the input voltage is within allowable limits. A TTL logic HIGH level, and a 5mS
early warning signal before 12.0 V DC output loss of regulation.
When left open power supply operation will be inhibited. When the power supply is
inserted into the system, this pin will be pull low by the system and turn the power supply on only
after all other power supply pins have seated.
The output will be enabled when this signal is pulled low, below 0.8 V outputs disabled when pin
is driven high or left open.
Active TTL high when output is within regulation limits.
30
AMBIENT DEG C
35
Tolerance
Set Point
±0.2%
±0.2%
±0.2%
±0.2%
40
45
50
Regulation
Total
55
±5%
±5%
±5%
±5%
60
65
Minimum
Current
-10° to 50 °C
-40 °C to +85 °C
10,000 ft
-EN61000-3-2, -3-3
-EN61000-4-2, 4.3, 4-4, -4-5, 4-11 Level
-EN55024:1998
No tantalum caps.
20 to 90% RH, non-condensing
Complies with Astec Std. Specifications, Q3205
500K Hrs at full load, 40 °C
70
0 A
0 A
0 A
0 A
75
4.5
4
3.5
3
2.5
2
1.5
1
0.5
0
Maximum
Current
100 A
100 A
100 A
100 A
180 - 264 Vac
90 - 179 Vac
5 Vsb
Output Ripple
120 mV
120 mV
120 mV
120 mV
1400
1200
1000
P/P
800
600
400
200
0
0
118 A - 147.6 A*
118 A - 147.6 A*
118 A - 147.6 A*
118 A - 147.6 A*
Over Current
Embedded Power for
Business-Critical Continuity
20
Ambient Temperature (
Reverse Air Derating
1140W @ 25 °C
Output Power (W)
3.3 V @ 6 A
5.0 V @ 4 A
3.3 V @ 6 A
5.0 V @ 4 A
Stand-by
25
1025W @ 50 °C
°C
)
50
Air Flow
Rev. 03.15.11_22
REV †
REV †
STD
STD
760W @ 70 °C
70
DS1200
2 of 4
Ou

Related parts for DS1200-3-002