DS1200-3-002 Emerson Network Power, DS1200-3-002 Datasheet

no-image

DS1200-3-002

Manufacturer Part Number
DS1200-3-002
Description
POWER SUPPLY AC/DC 12V 1200W
Manufacturer
Emerson Network Power
Series
DS1200r
Datasheets

Specifications of DS1200-3-002

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
1200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
180 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 100A
Size / Dimension
11" L x 3.2" W x 1.57" H (279.4mm x 81.3mm x 39.9mm)
Power (watts) - Rated
1200W
Operating Temperature
-10°C ~ 50°C
Efficiency
91%
Approvals
CB, CE, cUL, EN, NEMKO, UL
Line Regulation
±5%
Load Regulation
±5%
Input Voltage
90 to 264V
Output Voltage
12V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1271
Rev.10.03.30_#0.1
DS1200-3 Series
Page 1
The DS1200-3 power supply features a very wide 90 to 264 Vac input voltage
range and employ active power factor correction to minimize input harmonic
current distortion and to ensure compliance with the international EN61000-3-2
standard – they have a power factor of 0.99 typical. The power supplies also
feature active ac inrush control, to automatically limit inrush current at turn-on to
55 A maximum.
The power supply employs a new patent-pending ultra high efficiency conversion
topology, together with an innovative power transformer and rectifier construction
that further improves power density and reduces interconnect power losses. The
power supply’s main +12 Vdc payload output is digitally programmable over the
2
range 11.4 to 12.6 Vdc, and users have a choice of standard I
C or advanced
TM
PMBus
communications. The control software runs under Windows® on any
standard PC, and uses a highly intuitive graphical user interface to simplify
power supply set-up.
The DS1200-3 can deliver up to 98.4 A from its main +12 Vdc payload output,
and up to 6 A from its +3.3 Vdc auxiliary output. The supply has a 1U x 2U form
factor – it measures 10.9 x 3.3 inches, with a height of 1.6 inches – and has a
power density of more than 21 watts per cubic inch. When fed with a 180 to 264
Vac input, the DS1200-3 can achieve a very high – 91 percent typical –
conversion efficiency at 50 percent full load.

Related parts for DS1200-3-002

DS1200-3-002 Summary of contents

Page 1

... PC, and uses a highly intuitive graphical user interface to simplify power supply set-up. The DS1200-3 can deliver up to 98.4 A from its main +12 Vdc payload output, and from its +3.3 Vdc auxiliary output. The supply has form factor – it measures 10.9 x 3.3 inches, with a height of 1.6 inches – and has a power density of more than 21 watts per cubic inch. When fed with a 180 to 264 Vac input, the DS1200-3 can achieve a very high – ...

Page 2

... Output Standard Voltage DS1200-3 12.0Vdc DS1200-3-002 12.0Vdc DS1200-3-003 12.0Vdc DS1200-3-004 12.0Vdc Options AC Cord Retainer Minimum Maximum Load Load 0A 98.4A 0A 98.4A 0A 98.4A 0A 98.4A Stand-By Air Flow Direction Supply Normal 3.3V@6A (DC Connector to Handle) Normal 5V@4A (DC Connector to Handle) Reversed 3.3V@6A (Handle to DC Connector) Reversed ...

Page 3

... Note 1 With power derating (see page 22 power derating curve) Model Symbol All models V ≤ 180Vac All models P > 180Vac All models All models All models DS1200-3 DS1200-3-002 DS1200-3-003 DS1200-3-004 All models T Operating All models All models Operating All models All models Min Typ ...

Page 4

... All THD All V = 264V IAC AC Internal, L and N 5x20mm, Quick Acting 16A, 250V V = 240V IAC 50/60 Hz IAC All f SW,PFC All f SW,DC- O,max V = 100V η IAC 200V IAC AC Rev.10.03.30_#0.1 DS1200-3 Series Min Typ Max 90 115/230 264 47 50/ 400 - - 300 - - 800 - - 450 Per IEC1000-3 ...

Page 5

... All models DS1200-3 Output Regulation DS1200-3-003 DS1200-3-002 DS1200-3-004 All models DS1200-3 Output Ripple, pk-pk DS1200-3-003 DS1200-3-002 DS1200-3-004 All models DS1200-3 Output Current DS1200-3-003 DS1200-3-002 DS1200-3-004 V Current Share Accuracy O V Minimum Current Share Loading O 1 Number of Parallel Units V Load Capacitance O V Dynamic Response O ...

Page 6

... AC or the PS_ON signal Delay from PS_ON active to output voltages within T10 regulation limits. Delay from PS_ON deactive to POWER GOOD de-asserted T11 low. being within regulation SB in regulation stay SB Rev.10.03.30_#0.1 DS1200-3 Series Min Typ Max - - 1000 - - 2000 100 ...

Page 7

... System Timing Specifications Figure 1. System Timing Diagram: Rev.10.03.30_#0.1 DS1200-3 Series Page 7 ...

Page 8

... DS1200-3 Performance Curves ° ° ° ° Rev.10.03.30_#0.1 DS1200-3 Series Page 8 ° ° ° ° ...

Page 9

... DS1200-3 Performance Curves µ µ µ µ Output Current( Rev.10.03.30_#0.1 DS1200-3 Series Page 9 µ µ µ µ ...

Page 10

... Protection Function Specification Input Fusing DS1200-3 series is equipped with an internal non user serviceable 16A High Rupturing Capacity (HRC) 250 Vac fuse to IEC 127 for fault protection in both the L1 and L2 lines input. Over Voltage / Under Voltage Protection (OVP / UVP) The power supply latches off during output overvoltage with the AC line recycled to reset the latch. ...

Page 11

... Short Circuit Protection (SCP) The DS1200 power supply will withstand a continuous short circuit with no permanent damage, applied to its main output during start-up or while running.. A short is defined as impedance less than 0.1 ohms. When the standby output V is shorted the output will go into “hiccup mode”. When the V ...

Page 12

... Mechanical Outlines (Optional) Rev.10.03.30_#0.1 DS1200-3 Series Page 12 ...

Page 13

... C Address BIT 0 Signal – Address BIT 1 Signal) D3 – S_INT (Alarm) D4 – StandBy Remote Sense D5 – StandBy Output D6 – StandBy Output Return Earth Ground L1 L2 View from power supply output connector end PB1 Rev.10.03.30_#0.1 DS1200-3 Series Page 13 PB2 PB3 PB4 PB5 PB6 ...

Page 14

... Power / Signal Mating Connectors and Pin Types Table 5. Mating Connectors for DS1200-3 series Reference AC Input Connector Output Connector On Power Supply IEC320-C19 FCI Power Blade 51721-10002406AA or Molex Power Connector 87667-7002 Rev.10.03.30_#0.1 DS1200-3 Series Mating Connector or Equivalent IEC320-C20 FCI Power Blade 51741-10002406CC Straight Pins ...

Page 15

... ON OCP / UVP / OVP O FAN_FAULT / OTP / V = OCP/UVP SB One bi-color (green/red) LED at the power supply front provides status signal. The status LED conditions are shown on the below table. LED Status Blinking Green Solid Green Blinking Amber Solid Amber Rev.10.03.30_#0.1 DS1200-3 Series Page 15 ...

Page 16

... Weight The DS1200-3 series weight is 2.9 lbs. maximum. Rev.10.03.30_#0.1 DS1200-3 Series Page 16 ...

Page 17

... EMC Immunity DS1200-3 series power supply is designed to meet the following EMC immunity specifications: Table 6. Environmental Specifications: Document FCC Docket No. 20780 Part 15 Subpart J Class B/ EN55022, Level B EN61000-3-2 EN61000-3-3 IEC/EN 61000-4-2, Edition 1.2, 2001-04 IEC/EN 61000-4-3, 2002, Amendment 1, 2002-08 IEC/EN 61000-4-4, 1995, Amendment 2, 2001-07 IEC/EN 61000-4-5, Edition 1 ...

Page 18

... Safety Certifications The DS1200-3 power supply is intended for inclusion in other equipment and the installer must ensure that compliance with all the requirements of the end application. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. ...

Page 19

... EMI Emissions The DS1200 series has been designed to comply with the Class B limits of EMI requirements of EN55022 (FCC Part 15) and CISPR 22 (EN55022) for emissions and relevant sections of EN61000 (IEC 61000) for immunity. The unit is enclosed inside a metal box, tested at 1200W using resistive load with cooling fan. ...

Page 20

... In such a set-up possible to form a perfect dipole antenna that very few ac-dc convertors could pass. However, the standard also states that ‘an attempt should be made to maximize the disturbance consistent with the typical application by varying the configuration of the test sample. Rev.10.03.30_#0.1 DS1200-3 Series Page 20 ...

Page 21

... Operating Temperature The DS1200-3 series power supplies will start and operate within stated specifications at an ambient temperature from -10 °C to 50°C under all load conditions with internal fan. DS1200-3-002 and DS1200-3-401 can operate °C with derated power. Forced Air Cooling The DS1200-3 series power supplies included internal cooling fans as part of the power supply assembly to provide forced air-cooling to maintain and control temperature of devices and ambient temperature in the power supply to appropriate levels ...

Page 22

... Red Curve in the Power Derating Curves below). When ambient temperature drops back down DS1200-3-002 and DS1200-3-401 will able to deliver full rated power again (shown by the Blue Curve in the Power Derating Curves). See tables below for nominal output current / power and OCP limits at high temperature operation. Output ...

Page 23

... Note 1: Rated output power 1000W at 100Vac line condition, for lower line voltage derate output power to 550W (thermal limitation due to OTP Protection) for Red curve is the power transition from fill power to derated power Blue curve is the power transition from derated power to full power Ambient Temperature (degC) Rev.10.03.30_#0 ambient temperature DS1200-3 Series Page 23 ...

Page 24

... The DS1200-3 series power supplies can be stored or shipped at temperatures between –40 °C to +85 °C and relative humidity from 5% to 95% non-condensing. Altitude The DS1200-3 series will operate within specifications at altitudes up to 10,000 feet above sea level. The power supply shall not be damaged when stored at altitudes 30,000 feet above sea level. Humidity The DS1200-3 series will operate within specifications when subjected to a relative humidity from 20% to 90% non- condensing ...

Page 25

... Shock The DS1200-3 power supply will pass the following vibration specifications: Non-Operating Half-Sine Shock Acceleration 30 Duration 18 Pulse Half-Sine No. of Shock 3 shock on each of 6 faces Operating Half-Sine Shock Acceleration 4 Duration 22 Pulse Half-Sine No. of Shock 3 shock on each of 6 faces Rev.10.03.30_#0.1 DS1200-3 Series G msec ...

Page 26

... C interface signal connections. PS_ON – (pin A1) This signal input pin controls the normal turning ON and Off of the Main Output of the DS1200-3 power supply. The power supply main output (V ) will be enabled when this signal is pulled low, below 0.8 V. The Power supply output (except V O output) will be disabled when this input is driven higher than 2 ...

Page 27

... StandBy Output, StandBy Output Return – (pins A5, A6, B5, B6, C5, C6, D5, D6) The DS1200-3 provides a regulated 3.3 volt 6 amp (or 5.0 volt 4 amp) auxiliary output voltage to power critical circuitry that must remain active regardless of the on/off status of the power supply’s main output. The Standby Output (V available whenever a valid AC input voltage is applied to the unit ...

Page 28

... Please refer to “Communication Bus Descriptions” section. StandBy Remote Sense – (pin D4) The StandBy Output of the DS1200-3 is also equipped with a Remote Sensing capability that will compensate upto 50mV of voltage drop for the positive rail. The StandBy Output Remote Sense pin should be connected as close to the load as possible, or connected to the StandBy Output pins at the base of the output connector if not used ...

Page 29

... I C Bus Signals The DS1200-3 power supply contains enhanced monitoring and control functions implemented via the I 2 DS1200 functionality (PMBus communication bus is powered either by the internal 3.3V supply or from an external power source connected to the StandBy Output (ie: accessing an unpowered power supply as long as the StandBy Output of another power supply connected in parallel is on) ...

Page 30

... POWER SUPPLY SIDE System 3.3V (Internal Secondary Logic Supply 2 C signals (referenced to StandBy Output Return pin, unless otherwise Condition Symbol R int C int 1 PSU R ext 4 PSU Rev.10.03.30_#0.1 DS1200-3 Series A0 A1 PSU Monitor Function SDA SCL PSU Micro Controller S_INT FRU DATA EEPROM Min Typ ...

Page 31

... Logic Levels 2 DS1200-3 series power supply I C Communication Bus will respond to logic levels as per below: Logic High: 3.3V Nominal (Specs is 2.1V to 5.5V)** Logic Low: 500mV nominal (Specs is 800mV max)** 2 ** Note: Emerson I C adapter was used. 73-769-001 Timings Parameter SCL Clock Frequency ...

Page 32

... Device Addressing The DS1200-3 series will respond to supported commands on the I to pins A1 and A0 pins of output connector. Address pins are held HIGH by default via pulled up to internal 3.3V (5V)supply with a 1K resistor. To set the address as “0”, the corresponding address line should be pulled down to logic ground level. Below tables show the address of the power supply with A0 and A1 pins set to either “ ...

Page 33

... This bit will be cleared when the SB ) status within regulation limits. This bit will be cleared when the V O Status Register Code Code (Binary) 00011111 00011110 10011111 01011110 00111110 00001110 00010100 00011010 Rev.10.03.30_#0.1 DS1200-3 Series BIT 2 BIT 1 TEMP_OK Code (Hex ...

Page 34

... I C Clock Synchronization The DS1200-3 power supply might apply clock stretching. An addressed slave power supply may hold the clock line (SCL) low after receiving (or sending) a byte, indicating that it is not yet ready to process more data. The system master that is communicating with the power supply will attempt to raise the clock to transfer the next bit, but must verify that the clock line was actually raised ...

Page 35

... FRU (EEPROM) Data The FRU (Field Replaceable Unit) data format is compliant with the Intel IPMI v1.0 specification. The DS1200-3 uses 1 page of EEPROM for FRU purpose. A page of EEPROM contains up to 256 byte-sized data locations. Where: OFFSET - The OFFSET denotes the address in decimal format of a particular data byte within DS1200-3 EEPROM ...

Page 36

... DS1200-3 FRU (EEPROM) Data: OFFSET (DEC) (HEX CHASSIS SERIAL NUMBER BYTES, Default value End Tag (0C1h if used CHKSUM (Zero CHKSUM if used FORMAT VERSION NUMBER (Product Info Area) 7:4 - Reserved, write as 0000b 3:0 - Format Version Number = 1h for this specification 41 29 PRODUCT INFO AREA LENGTH (In multiples of 8 bytes) ...

Page 37

... DS1200-3 FRU (EEPROM) Data: OFFSET (DEC) (HEX) PRODUCT SERIAL NUMBER Type/Length 78 4E Type = “ASCII+LATIN1” = (11)b Length = 13 bytes = (001101 Model “G087” for DS1200 Decimal = 071, 048, 056, 055 Hex = 47H, 30H, 38H, 37H MANUFACTURING YEAR AND WEEK CODE 83 53 “WW” ...

Page 38

... DS1200-3 FRU (EEPROM) Data: OFFSET (DEC) (HEX) 111 6F Low End Input Voltage Range 2(10mV) 112 70 Not Applicable (Autoswitch) 113 71 High End Input Voltage Range 2(10mV) 114 72 Not Applicable (Autoswitch) 115 73 Low End Input Frequency Range, 47Hz = 2FH 116 74 Low End Input Frequency Range, 63Hz = 3FH ...

Page 39

... DS1200-3 FRU (EEPROM) Data: OFFSET (DEC) (HEX) Maximum Positive Voltage Deviation (10mV), 1260 =04ECH 2 Bytes Sequence 135 87 In Decimal: 236, 004 136 88 In Hex: ECH, 04H Ripple and Noise pk-pk (mV), 120 = 78H 2 Bytes Sequence 137 89 In Decimal: 120, 000 138 8A In Hex: 78H, 00H ...

Page 40

... DS1200-3 FRU (EEPROM) Data: OFFSET (DEC) (HEX) 163 A3 Record Length of OEM Record 164 A4 Record CHECKSUM of OEM Record (Zero CHECKSUM) 165 A5 Header CHECKSUM of OEM Record Header (Zero CHECKSUM) (256-(sum of bytes 161 to 164) 166 A6 Manufacturer ID (3 bytes, Default is 0) 167 A7 168 A8 169 ...

Page 41

... DS1200-3 FRU (EEPROM) Data: OFFSET (DEC) (HEX) 216 D8 RESERVED, Default value is 0. 217 D9 218 DA 219 DB 220 DC 221 DD 222 DE 223 DF 224 E0 225 E1 226 E2 227 E3 228 E4 229 E5 230 E6 231 E7 232 E8 233 E9 234 EA 235 EB 236 EC 237 ED 238 EE 239 EF 240 F0 241 F1 242 F2 243 F3 244 F4 245 ...

Page 42

... DS1200-3-002 FRU (EEPROM) deviations: OFFSET (DEC) (HEX) PRODUCT NAME BYTES (12 Byte sequence "D" = 44h 51 33 "S" = 53h 52 34 "1" = 31h 53 35 "2" = 32h 54 36 "0" = 30h 55 37 "0" = 30h 56 38 "-" = 2Dh 57 39 "3" = 33h 58 3A "-" = 2Dh 59 3B " ...

Page 43

... DS1200-3-002 FRU (EEPROM) deviations: OFFSET (DEC) (HEX) 143 8F Record type = 01 for DC Output Record 144 90 End of List /Record Format Version Number for 5VSB Output Record 154 91 Record Length of 5VSB Output Record 146 92 Record CHECKSUM of 5VSB Output Record (Zero CHECKSUM) (256-(sum of bytes 148 to 160) ...

Page 44

... DS1200-3-003 FRU (EEPROM) deviations : OFFSET (DEC) (HEX) PRODUCT NAME BYTES (12 Byte sequence "D" = 44h 51 33 "S" = 53h 52 34 "1" = 31h 53 35 "2" = 32h 54 36 "0" = 30h 55 37 "0" = 30h 56 38 "-" = 2Dh 57 39 "3" = 33h 58 3A "-" = 2Dh 59 3B " ...

Page 45

... DS1200-3-003 FRU (EEPROM) deviations: OFFSET (DEC) (HEX) 143 8F Record type = 01 for DC Output Record 144 90 End of List /Record Format Version Number for 3V3SB Output Record 154 91 Record Length of 3V3SB Output Record 146 92 Record CHECKSUM of 3V3SB Output Record (Zero CHECKSUM) (256-(sum of bytes 148 to 160) ...

Page 46

... DS1200-3-004 FRU (EEPROM) deviations : OFFSET (DEC) (HEX) PRODUCT NAME BYTES (12 Byte sequence "D" = 44h 51 33 "S" = 53h 52 34 "1" = 31h 53 35 "2" = 32h 54 36 "0" = 30h 55 37 "0" = 30h 56 38 "-" = 2Dh 57 39 "3" = 33h 58 3A "-" = 2Dh 59 3B " ...

Page 47

... DS1200-3-004 FRU (EEPROM) deviations: OFFSET (DEC) (HEX) 143 8F Record type = 01 for DC Output Record 144 90 End of List /Record Format Version Number for 5VSB Output Record 154 91 Record Length of 5VSB Output Record 146 92 Record CHECKSUM of 5VSB Output Record (Zero CHECKSUM) (256-(sum of bytes 148 to 160) ...

Page 48

... The DS1200-3 is compliant with the industry standard PMBus 2 the I C interface port. TM DS1200-3 Series PMBus Equipment Setup 2 The following is typical I C communication setup Master TM PMBus Writing Instructions TM When writing to any PMBus R/W registers, ALWAYS do the following: Disable Write Protect (command 10h) by writing any of the following accordingly: Levels: 00h – ...

Page 49

... DS1200-3 Series Support PMBus The DS1200-3 is compliant with the industry standard PMBus 2 power supply via the i C interface port. DS1200-3 Series Supported PMBus Command Command Name Code 01h OPERATION b7:6 b5:4 b3:2 b1:0 02h ON_OFF_CONFIG b7:5 b4 – Enable PS_ON pin and Serial communication control. b3 – ...

Page 50

... DS1200-3 Series Supported PMBus Command Command Name Code 19h CAPABILITY b7 - Packet Error Checking b6 - Maximum Bus Speed b5 - SMBALERT# b4:0 20h VOUT_MODE 21h VOUT_COMMAND 22h VOUT_TRIM 23h VOUT_CAL_OFFSET 24h VOUT_MAX 30h COEFFICIENTS byte 0:1 byte 2:3 byte 4:5 31h POUT_MAX 35h VIN_ON 36h ...

Page 51

... DS1200-3 Series Supported PMBus Command Command Name Code 3Ah FAN_ CONFIG_1_2 b1:0 3Bh FAN_COMMAND_1 40h VOUT_OV_FAULT_LIMIT 41h VOUT_OV_FAULT_RESPONSE 42h VOUT_OV_WARN_LIMIT 43h VOUT_UV_WARN_LIMIT 44h VOUT_UV_FAULT_LIMIT 45h VOUT_UV_FAULT_RESPONSE 46h IOUT_OC_FAULT_LIMIT 47h IOUT_OC_FAULT_RESPONSE 4Ah IOUT_OC_WARN_LIMIT 4Fh OT_FAULT_LIMIT 50h OT_FAULT_RESPONSE 51h OT_WARN_LIMIT 55h VIN_OV_FAULT_LIMIT ...

Page 52

... DS1200-3 Series Supported PMBus Command Command Name Code 5Ch IIN-OC-FAULT_RESPONSE 5Eh POWER_GOOD_ON 5Fh POWER_GOOD_OFF 60h TON_DELAY 61h TON_RISE 64h TOFF_DELAY 78h STATUS_BYTE b7 – BUSY b6 – OFF b5 – VOUT_OV b4 – IOUT_OC b3 - VIN_UV b2 - TEMPERATURE b1 – CML b0 – NONE OF THE ABOVE 79h STATUS_WORD b15 – VOUT b14 – ...

Page 53

... DS1200-3 Series Supported PMBus Command Command Name Code 7Ah STATUS_VOUT 7Bh STATUS_IOUT 7Ch STATUS_INPUT 7Dh STATUS_TEMPERATURE b3:0 7Eh STATUS_CML Command List: Access Data Default Value Type Bytes - Data Description Format Output voltage related faults and warnings VOUT Over--voltage Fault VOUT Over-voltage warning ...

Page 54

... DS1200-3 Series Supported PMBus Command Command Name Code 80h STATUS_MFR_SPECIFIC 81h STATUS_FANS_1_2 88h READ_VIN 89h READ_IIN 8Ah READ_VCAP 8Bh READ_VOUT 8Ch READ_IOUT 8Eh READ_TEMPERATURE_2 90h READ_FAN_SPEED_1 96h READ_POUT 97h READ_PIN 98h PMBUS_REVISION b7:5 b4:0 99h MFR_ID 9Ah MFR_MODEL 9Bh MFR_REVISION 9Ch ...

Page 55

... DS1200-3 Series Supported PMBus Command Command Name Code A3 MFR_PIN_MAX A4h MFR_VOUT_MIN A5h MFR_VOUT_MAX A6h MFR_IOUT_MAX A7h MFR_POUT_MAX A8h MFR_TAMBIENT_MAX A9h MFR_TAMBIENT_MIN D1h STBY_UV D2h Min Fan Speed D3h Max Fan Speed E2h Ishare Offset E3h Ishare Slope EAh ENTER_BOOTLOAD EEh FIRMWARE_VERSION ...

Page 56

... DS1200-3 Series Supported PMBus Command Command Name Code F7h Calibration Register b7 – PSU Calibrated and Tested b6 – – – – – Command List: Access Data Default Value Type Bytes R 1 Data Description Format PSU is Calibrated and Passed all Functional Tests Bit is set if PSU Calibrated and has Passed all Functional Tests ...

Page 57

... The latch of the DS1200-3 power supply is designed to prevent the latch from depressed if the AC cord is attached to the power supply. In order to remove the power supply from system chassis, the AC cord must be removed first so the power supply will always be in the powered off state during the removal from system chassis ...

Page 58

... The setup outlined in the diagram below has been used for output voltage ripple and noise measurements on the DS1200-3 Series. When measuring output ripple and noise, a scope jack in parallel with a 0.1uF ceramic chip capacitor, and aluminum electrolytic capacitor should be used. Oscilloscope should be set to 20 MHz bandwidth for this measurement ...

Page 59

... Rev.10.03.16_#0.1 DS1200-3 Series Americas 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 (760) 930 4600 Facsimile: +1 (760) 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 ...