LK5660-7R POWER ONE, LK5660-7R Datasheet - Page 5

CONVERTER AC/DC 225VIN 48VOUT

LK5660-7R

Manufacturer Part Number
LK5660-7R
Description
CONVERTER AC/DC 225VIN 48VOUT
Manufacturer
POWER ONE
Series
Kr
Datasheet

Specifications of LK5660-7R

Voltage - Output
24V
Number Of Outputs
2
Power (watts)
150W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 255VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 3A
2nd Output
24 VDC @ 3A
Size / Dimension
6.63" L x 4.37" W x 3.15" H (168.5mm x 111mm x 80mm)
Power (watts) - Rated
150W
Operating Temperature
-25°C ~ 71°C
Efficiency
83%
Approvals
CE, cUL, EN, TUV
Output Voltage (channel 1)
24 V
Output Current (channel 1)
3 A
Output Voltage (channel 2)
24 V
Output Current (channel 2)
3 A
Isolation Voltage
2.8 KV
Output Type
Isolated
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
LK 5660-7R
LK 5660-7R
Q1660869
Electrical Input Data
General Conditions:
Table 3: Electrical input data
Input Fuse and Protection
A VDR together with the input fuse and a symmetrical input
filter form an effective protection against high input
transient voltages.
A fuse mounted inside the converter in series to the phase
line protects against severe defects. A second fuse in the
neutral line may be necessary in certain applications; see
Installation Instructions.
Table 4: Fuse specification
Input Under- /Overvoltage Lockout
If the input voltage remains below approx. 65 VAC (LKP:
150 VAC) or exceeds V
signal disables the output(s). Do not check the overvoltage
lockout function!
If V
level, the output voltage may be below the value specified
in the tables Electrical Output Data.
BCD20001-G Rev AC, 16-Dec-2010
Input
Characteristics
V
V
V
I
P
P
R
R
C
V
V
LK4/5000
Model
LKP
i
– T
– Pin 18 connected to pin 14, R input not connected, V
– Sense line pins S+ and S– connected to Vo+ and Vo–, respectively (single-output models)
1
2
3
4
i
i op
i nom
i RFI
i abs
i0
i inh
NTC
b
i
Rated input frequency: 50 – 60 Hz, operating frequency: 47 – 63 Hz. For operation at other frequencies, contact Power-One.
With double-output models, both outputs loaded with I
Valid for models without option E. This is the value of the NTC resistance at 25 °C and applies to cold converters for the initial
switch-on cycle. Subsequent switch-on/off cycles increase the inrush current peak value.
Operation with DC input voltage is not specified and not recommended.
i
is below V
A
= 25 °C, unless T
Rated input voltage range
Operating input voltage range
Nominal input voltage
Input current
No-load input power
Idle input power
Input resistance
NTC resistance (see fig. 3)
Input capacitance
Conducted input RFI
Radiated input RFI
Input voltage limits
without damage
Fuse type
slow-blow
slow-blow
i min
, but above the undervoltage lockout
i abs
C
is specified.
, an internally generated inhibit
Fuse rating
SP T, 4 A, 250 V, 5
SP T, 4 A, 250 V, 5
3
Conditions
I
T
50 – 60 Hz
V
V
converter inhibited
conv. not operating
EN 55011/55022
V
o
C min
i nom
i nom
i min
= 0
, I
, I
to T
o nom
o nom
V
I
o nom
i max
C max
20 mm
20 mm
2
, I
o nom
o
= 0
Page 5 of 29
o
adjusted to V
–400
3200
min
100
480
100
85
Inrush Current Limitation
The models without option E incorporate an NTC resistor
in the input circuitry, which at initial turn-on reduces the
peak inrush current value by a factor of 5 to 10 to protect
connectors and switching devices against damage.
Subsequent switch-on cycles within short periods will
cause an increase of the peak inrush current value due to
the warming-up of the NTC resistor.
The inrush current peak value (initial switch-on cycle) can
be determined by following calculation:
Fig. 3
Equivalent circuit diagram for input impedance.
I
inr p
= ––––––––––––––––
4000
V
230
150
typ
150 – 280 Watt AC-DC Converters
0.8
3.5
LK
A
i
9
B
o nom
(R
R
s ext
s ext
V
K Series with PFC Data Sheet
(option P)
max
i
240
264
180
283
400
10
5
+ R
I
inr p
––
2
i
+ R
–400
3200
min
200
187
480
110
NTC
)
R
i
4000
LKP
1.25
typ
230
136
3.5
B
B
9
R
NTC
max
240
255
165
283
400
www.power-one.com
10
5
C
VAC
VDC
VAC
Unit
m
b
W
A
F
04001b
4
1
+

Related parts for LK5660-7R