LK5660-7R POWER ONE, LK5660-7R Datasheet - Page 22

CONVERTER AC/DC 225VIN 48VOUT

LK5660-7R

Manufacturer Part Number
LK5660-7R
Description
CONVERTER AC/DC 225VIN 48VOUT
Manufacturer
POWER ONE
Series
Kr
Datasheet

Specifications of LK5660-7R

Voltage - Output
24V
Number Of Outputs
2
Power (watts)
150W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 255VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 3A
2nd Output
24 VDC @ 3A
Size / Dimension
6.63" L x 4.37" W x 3.15" H (168.5mm x 111mm x 80mm)
Power (watts) - Rated
150W
Operating Temperature
-25°C ~ 71°C
Efficiency
83%
Approvals
CE, cUL, EN, TUV
Output Voltage (channel 1)
24 V
Output Current (channel 1)
3 A
Output Voltage (channel 2)
24 V
Output Current (channel 2)
3 A
Isolation Voltage
2.8 KV
Output Type
Isolated
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
LK 5660-7R
LK 5660-7R
Q1660869
Safety of Operator-Accessible Output Circuits
If the output circuit of a converter is operator-accessible, it
shall be an SELV circuit according to IEC/EN 60950.
The
configuration, compliance with which causes the output
circuit of a K Series AC-DC converter to be a SELV circuit
according to IEC/EN 60950 up to a configured output voltage
of 36 V (sum of nominal voltages connected in series) .
However, it is the sole responsibility of the installer to
ensure compliance with the applicable safety regulations.
Table 18: Safety concept leading to a SELV output circuit
Description of Options
Table 19: Survey of options
-9 Extended Temperature Range
Option -9 extends the operational ambient temperature
range from –25 to 71 °C (standard) to – 40 to 71 °C. The
power supplies provide full nominal output power with
convection cooling. Option -9 excludes inrush current
limitation by NTC.
E Inrush Current Limitation
The converters exhibit an electronic circuit replacing the
standard built-in NTC, in order to achieve an enhanced
inrush current limiting function.
BCD20001-G Rev AC, 16-Dec-2010
Conditions
Nominal voltage
Mains
B, B1, B2
1
2
Option
1
250 VAC
Option D excludes option V and vice versa; option V only for 5.1 V outputs.
Option P is not available for battery charger models.
The earth connection has to be provided by the installer according to the relevant safety standards, e.g., IEC/EN 60950.
P
D
V
-9
K
G
E
T
2
1
1
table
Function of option
Extended operational ambient temperature range
Electronic inrush current limitation circuitry
Potentiometer for fine adjustment of output voltage
Input and/or output undervoltage monitoring circuitry
Input and/or output undervoltage monitoring circuitry
Current sharing
H15S4 connector for models with 5.1 V output
Cooling plate (160 or 220 mm long)
RoHS-compliant for all six substances
below
AC-DC converter
Grade of insulation
between input and output
provided by the AC-DC converter
Double or reinforced
shows
a
possible
installation
Page 22 of 29
Installation
Measures to achieve the resulting
safety status of the output circuit
Earthed case
according to the applicable standards
Characteristic
T
Active inrush current limitation
Adjustment range +10 / – 60% of V
Safe data signal output (D0 – DD)
ACFAIL signal according to VME specifications (V0, V2, V3)
Interconnect T-pins if paralleling outputs (max 5 converters)
For new designs; provides compatibility with LK1001 models
Replaces standard heat sink, allowing direct chassis-mounting
G is always the last character in the type designation
Fig. 32
Schematic safety concept.
Fig. 33
Option E block diagram
A
= – 40 to 71 °C
Earth
connection
Mains
1
and installation
150 – 280 Watt AC-DC Converters
~
~
Rectifier
K Series with PFC Data Sheet
Fuse
Fuse
R
s
Control
o nom
Result
Safety status of the AC-DC
SELV circuit
converter output circuit
R
AC-DC
FET
verter
I
, excludes R input
con-
10021a
www.power-one.com
SELV
+
C
b
11001b
+

Related parts for LK5660-7R