ZUP120-3.6/U TDK Corporation, ZUP120-3.6/U Datasheet - Page 52

PWR SUP BENCH PROG 0-120V 432W

ZUP120-3.6/U

Manufacturer Part Number
ZUP120-3.6/U
Description
PWR SUP BENCH PROG 0-120V 432W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Enclosedr
Datasheets

Specifications of ZUP120-3.6/U

Number Of Outputs
1
Efficiency
87%
Voltage - Output
0 ~ 120V
Power (watts)
432W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 120 VDC @ 3.6A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
432W
Operating Temperature
0°C ~ 50°C
Approvals
CE, EN, UL
Line Regulation
0.01%
Load Regulation
0.01%
Output Current (max)
3.6A
Input Voltage
85 to 265V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
285-1672
ZUP1203.6/U
2. Alarm Status Register:
The alarm status register records fault conditions occurring during power supply operation. Any set bit
in this register causes the ‘alarm’ bit in the operational status register to be set. Reading the register
does not change it’s content. The register is cleared by :DCL; command.
Table 5-6: Alarm status register content.
Notes: (*1) Since at each AC turn off the AC fail bit is generated and stored, it is recommended to
3. Error Codes Register:
The error codes register records errors that occurred during the programming of the power supply. Any
set bit in this register causes the ‘prog’ bit in the alarm status register to be set. Reading the register
does not change it’s content. The register is cleared by :DCL; command.
Table 5-7: Error codes register content.
5.5.4.2 Status control commands
Bit Name
ovp
otp
a/c fail
fold
prog
Bit Name
not used
wrong command
buffer overflow
wrong voltage
wrong current
2
#
1
Commands
:ALM?;
:STA?;
(*2) FOLD bit is automatically reset upon cancellation of FOLD protection.
(*3) OVP, OTP and ‘prog’ bits reset at AC turn-off or by :DCL; command.
send a :DCL; command following application of AC voltage to the power supply, to clear the
alarm status register.
In case the OTP or OVP is triggered, the front panel control is disabled until the AC input is
recycled by turning the AC ON/OFF switch to OFF and after approx. 10 sec. to ON.
Bit No
1
2
3
4
5
Bit No
1
2
3
4
5
‘1’ - Indicates that the over-voltage protection was tripped
‘1’ - Indicates that the over-temperature protection was tripped
‘1’ - Indicates that a failure occurred at the input voltage supply
‘1’ - Indicates that the foldback protection was activated
‘1’ - Indicates a programming error has occurred
Meaning
Reads the alarm status register content.
Returns the string AL followed by ASCII characters representing the
register’s content.
Refer to table 5-6 for the register content description.
example- AL00000
Reads the operational status register content.
Returns the string
register’s content.
Refer to table 5-5 for the register content description.
example- OS00010000
Description
‘1’ - Indicates that an unknown string was received
‘1’ - Indicates an overflow in the communication buffer
‘1’ - Indicates an attempt to program the power supply to a voltage
out of specification limits.
‘1’ - Indicates an attempt to program the power supply to a current
out of specification limits.
Meaning
OS
followed by ASCII characters representing the
(*3)
(*3)
(*1)
(*2)
(*3)

Related parts for ZUP120-3.6/U