ZUP120-3.6/U TDK Corporation, ZUP120-3.6/U Datasheet - Page 49

PWR SUP BENCH PROG 0-120V 432W

ZUP120-3.6/U

Manufacturer Part Number
ZUP120-3.6/U
Description
PWR SUP BENCH PROG 0-120V 432W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Enclosedr
Datasheets

Specifications of ZUP120-3.6/U

Number Of Outputs
1
Efficiency
87%
Voltage - Output
0 ~ 120V
Power (watts)
432W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 120 VDC @ 3.6A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
432W
Operating Temperature
0°C ~ 50°C
Approvals
CE, EN, UL
Line Regulation
0.01%
Load Regulation
0.01%
Output Current (max)
3.6A
Input Voltage
85 to 265V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
285-1672
ZUP1203.6/U
5.5.3 Output control
2
3
#
1
4
:VOL?;
:CURn;
:VOL!;
Commands
:VOLn;
Returns the string
output voltage value. The actual voltage range is as shown in table 5-1.
example: SV5.010
Table 5-2: Current programming range.
Returns the string
The actual voltage range is the same as the programming range.
example: AV5.010 AV08.500
Sets the output current in Ampers. This programmed current is the actual
output current at constant-current mode or the current limit at constant
voltage mode. The programming range is shown in table 5-2:
Use all digits for current programming.
Sets the output voltage value in volts. This programmed voltage is the
actual output at constant-voltage mode or the voltage limit at constant
current mode. The range of the voltage values are as shown in table 5-1.
Use all digits for voltage programming
Table 5-1: Voltage programming range.
Example - ZUP6-XY :VOL5.010;
Description
Example - ZUP60-3.5 :CUR3.000;
ZUP6-XY
ZUP10-XY
ZUP20-XY
ZUP36-XY
ZUP60-XY
ZUP80-XY
ZUP120-XY
Model
ZUP6-33
ZUP6-66
ZUP6-132
ZUP10-20
ZUP10-40
ZUP10-80
ZUP20-10
ZUP20-20
ZUP20-40
ZUP36-6
ZUP36-12
ZUP36-24
ZUP60-3.5
ZUP60-7
ZUP60-14
ZUP80-2.5
ZUP80-5
ZUP120-1.8
ZUP120-3.6
Model
000.00
00.000
00.000
00.000
00.000
00.000
00.000
0.0000
0.0000
00.000
00.000
00.00
00.00
00.00
00.00
00.00
0.000
0.000
0.000
0.000
0.000
MIN.
0.000
00.00
00.00
00.00
000.00
MIN.
AV
SV
(Actual Voltage) followed by the actual output voltage.
(Set Voltage) followed by the present programmed
132.00
20.000
10.000
20.000
12.000
24.000
14.000
2.5000
1.8000
3.600
MAX.
33.00
66.00
40.00
80.00
40.00
6.000
3.500
7.000
5.000
SV08.500
10.000
20.000
120.00
MAX.
6.000
36.00
60.00
80.00
Note:
The ZUP can accept values higher by 5%
than the rating. It is recommended to set the
output current to 105% of the rating if the
unit is required to supply the rated current.
Note:
The ZUP can accept programmed value
higher by up to 5% than the table values,
however it is not recommended to program
power supply over the rated voltage.
ZUP10-XY :VOL08.500;
ZUP10-40 :CUR07.50;

Related parts for ZUP120-3.6/U