Specifications of MAP130-1012

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
130W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 12A
Size / Dimension
8.5" L x 4.5" W x 2" H (215.9mm x 114.3mm x 50.8mm)
Power (watts) - Rated
130W
Operating Temperature
0°C ~ 50°C
Efficiency
80%
Approvals
CE, CSA, EN, TUV, UL
Line Regulation
0.2%
Load Regulation
1%
Output Current (max)
12/10A
Input Voltage
90 to 132/175 to 264V
Output Voltage
12/15V
Output Power (max)
130W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Length (mm)
215.9mm
Product Height (mm)
50.8mm
Product Depth (mm)
114.3mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Mounting Style
Surface Mount
Pin Count
15
Product
Switching
Brand/series
MAP130 Series
Configuration
Open-Frame
Current, Input
3.3 A (RMS)(90 VAC)
Current, Output
12⁄10 A
Dimensions
8.5 in. L x 4.5 in. W x 2 in. H
Frequency, Operating
47 to 63 Hz (AC Input), 16 to 120 kHz
Operation
Switching
Output
12 VDC @ 12 A/15 VDC @ 10 A
Power, Output
130 W
Power, Rating
130 W
Primary Type
AC-DC
Special Features
Power Fail, Remote Sense
Standards
UL Listed, CSA Certified
Temperature, Operating
0 to +50 °C
Voltage, Input
115/230 VAC
Voltage, Output
12/15 VDC
En61000-4-2 Esd Level 4 (8 Kv)
All Map Products
En61000-4-3 Radiated Level 3 (10 V/m)
All Map Products
Universal Input
90-132 VAC or 175-264 VAC
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
179-2080
PW9900
Multiple Output Model Selection (Cont.)
NOTES: 1) Peak loads up to 165 Watts, (total of all outputs), for 60 seconds or less are acceptable, (10% duty cycle max.).
Input Specifications
PARAMETER
Input Voltage- AC
Input Frequency
Brown out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Operating Frequency
Output Specifications
PARAMETER
Efficiency
Minimum Loads
Ripple and Noise
Output Power
Overshoot /Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
MCD10115 Rev. 1.3, 05-Feb-10
MODEL
MAP130-4003
MAP130-4004
MAP130-4010
MAP130-4020
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
VOLTAGE
OUTPUT
+15V
+24V
+15V
+12V
+12V
-15V
-15V
-12V
-12V
+5V
+5V
+5V
+5V
-5V
-5V
-5V
4.75V to 5.50V
14.0V to 16.0V
4.75V to 5.50V
23.0V to 25.0V
4.75V to 5.50V
11.5V to 12.8V
4.75V to 5.50V
11.5V to 12.8V
ADJUSTMENT
CONDITIONS/DESCRIPTION
Auto-ranging.
AC Input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Nominal AC input voltage (115 VAC).
90 VAC, 130W load.
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 264 VAC (one cycle). 25° C.
Switching frequency of main transformer (variable).
CONDITIONS/DESCRIPTION
Full Load, 115VAC. Varies with distribution of loads among outputs.
MAP130-1012.
MAP130-1024.
MAP130-1005 and all multiple output models, main channel only.
Full load, 20MHz bandwidth.
Continuous output power, all multiple output models.
Peak output power (60s maximum, 10% duty cycle), all multiple output models.
Output voltage overshoot/undershoot at turn-on / turn-off
Varies by output, Total regulation includes: line changes from 90-132 VAC
or 175-264, changes in load starting at 20% load and changing to 100% load.
Recovery time to within 1% of initial set point due to a 50-100% load change,
4% max. deviation. (Main output only on multi-output units)
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
RANGE
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
CURRENT
OUTPUT
3.5A
20A
20A
20A
20A
4A
1A
1A
1A
1A
5A
1A
3A
5A
1A
3A
130W Continuous Output Power
Page 2 of 4
PEAK CURRENT
(NOTE 1)
30A
30A
30A
10A
30A
10A
8A
1A
1A
5A
1A
1A
1A
3A
1A
3A
MAP130 AC-DC Series Data Sheet
REGULATION
0.2%
0.5%
0.5%
0.5%
0.2%
0.5%
0.5%
0.5%
0.2%
0.5%
0.5%
0.5%
LINE
1%
1%
2%
2%
Low Range
High Range
130W load:
Range:
REGULATION
LOAD
1%
2%
2%
2%
1%
2%
2%
2%
1%
2%
2%
2%
1%
2%
2%
2%
1.25
0.63
3.00
175
MIN
MIN
90
47
90
40
16
71
See Model Selection Chart
See Model Selection Chart
NOISE %p-p (NOTE 2)
TYPICAL RIPPLE &
NOM
115
230
NOM
3.3
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
www.power-one.com
MAX
132
264
120
MAX
130
165
500
63
38
80
20
-14.7V to -15.3V
-14.5V to -15.5V
-11.6V to -12.4V
-11.6V to -12.4V
11.75V to 12.0V
11.75V to 12.0V
1
2
15.0V to 15.1V
23.9V to 24.1V
14.5V to 15.5V
INITIAL SETTING
-4.8V to -5.2V
-4.8V to -5.2V
-4.8V to -5.2V
5.15V to 5.2V
5.1V to 5.25V
5.1V to 5.25V
5.1V to 5.2V
ACCURACY
Amps
Watts
UNITS
UNITS
A
VAC
VAC
mS
A
kHz
Sec
mS
µS
Hz
RMS
%
%
PK