... NOTES: 1) Typical peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 2) MAP130-1012 output currents are expressed as 12V/15V operation. MAP130-1024 output currents are expressed as 24V/28V operation. 3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum. Multiple Output Model Selection ...
Page 2
... Efficiency Full Load, 115VAC. Varies with distribution of loads among outputs. Minimum Loads MAP130-1012. MAP130-1024. MAP130-1005 and all multiple output models, main channel only. Ripple and Noise Full load, 20MHz bandwidth. Output Power Continuous output power, all multiple output models. Peak output power (60s maximum, 10% duty cycle), all multiple output models. ...
Page 3
... Warning prior to system shutdown due to excessive internal temperatures. (Note 2) Shifts Power Fail signal to a logic LO state. NOTES: 1) Power Fail not available on MAP130-1012 and MAP130-1024. 2) MAP130-1012 and MAP130-1024 have overtemperature protection, but do not have the warning feature. Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION Agency Approvals UL1950 ...
Page 4
... TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MCD10115 Rev. 1.3, 05-Feb-10 MAP130 AC-DC Series Data Sheet WEIGHT: 2.5 lb (1.13 kg) 0.045" (1.1mm) SQUARE PINS ON 0.156" (3.96mm) CENTERS; ...