YNV12T16-0G POWER ONE, YNV12T16-0G Datasheet

CONVERTER DC-DC 12V 16A SIP

YNV12T16-0G

Manufacturer Part Number
YNV12T16-0G
Description
CONVERTER DC-DC 12V 16A SIP
Manufacturer
POWER ONE
Series
Yr
Type
Point of Load (POL) Non-Isolatedr
Datasheet

Specifications of YNV12T16-0G

Output
0.75 ~ 5.5V
Number Of Outputs
1
Power (watts)
88W
Mounting Type
Through Hole
Voltage - Input
9.6 ~ 14V
Package / Case
10-SIP Module
1st Output
0.75 ~ 5.5 VDC @ 16A
Size / Dimension
2.00" L x 0.28" W x 0.54" H (50.8mm x 7.1mm x 13.7mm)
Power (watts) - Rated
88W
Operating Temperature
-40°C ~ 85°C
Efficiency
94%
Approvals
cUL, EN, UL
Package
10SIP
Output Current
16 A
Output Voltage
0.7525 to 5.5 V
Input Voltage
12 V
Output Power
88 W
Switching Regulator
Yes
Product
Non-Isolated / POL
Input Voltage Range
9.6 V to 14 V
Input Voltage (nominal)
12 V
Output Voltage (channel 1)
0.7525 V to 5.5 V
Output Current (channel 1)
16 A
Package / Case Size
SIP
Output Type
Regulated
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
179-2378
Applications
 Intermediate Bus Architectures
 Telecommunications
 Data communications
 Distributed Power Architectures
 Servers, workstations
Benefits
 High efficiency – no heat sink required
 Reduces total solution board area
 Minimizes part numbers in inventory
Description
Power-One’s point-of-load converters are recommended for use with regulated bus converters in an
Intermediate Bus Architecture (IBA). The YNV12T16 non-isolated DC-DC converters deliver up to 16 A of
output current in an industry-standard, through-hole (SIP) package. They operate from a 9.6 to 14 VDC input
and are ideal choices for Intermediate Bus Architectures where point-of-load power delivery is generally a
requirement. In addition, they provide a resistor-programmable regulated output voltage of 0.7525 V to 5.5 V.
The Y Series of non-isolated DC-DC converters provides exceptional thermal performance, even in high
temperature environments with minimal airflow. This is accomplished through the use of circuit, packaging
and processing techniques to achieve ultra-high efficiency, excellent thermal management and a very sleek
body profile.
The low body profile and the preclusion of heat sinks minimize impedance to system airflow, thus enhancing
cooling for both upstream and downstream devices. The use of 100% automation for assembly, coupled with
advanced power electronics and thermal design, results in a product with extremely high reliability.
ZD-02039 Rev. 3.2, 24-Jun-10
9.6-14 VDC Input; 0.7525-5.5 VDC Programmable @ 16 A
YNV12T16 DC-DC Converter Data Sheet
Page 1 of 28
The
Features
 RoHS lead-free solder and lead-solder-exempted
 Delivers up to 16 A (88 W)
 Extended input range 9.6 V – 14 V
 Industry-standard footprint and pinout
 Single-in-Line Package (SIP): 2.0” x 0.535” x 0.28”
 Weight: 0.25 oz [7 g]
 Synchronous Buck Converter Topology
 Start-up into pre-biased output
 No minimum load required
 Programmable output voltage via external resistor
 Operating ambient temperature: -40 °C to 85 °C
 Remote output sense
 Remote ON/OFF (Positive or Negative)
 Fixed-frequency operation
 Auto-reset output overcurrent protection
 Auto-reset overtemperature protection
 High reliability, MTBF = TBD Million Hours
 All materials meet UL94, V-0 flammability rating
 UL 60950 recognition in U.S. & Canada, and DEMKO
products are available
(50.8 x 13.59 x 7.11 mm)
certification per IEC/EN 60950
www.power-one.com
Products: Y-Series

Related parts for YNV12T16-0G

YNV12T16-0G Summary of contents

Page 1

... Description Power-One’s point-of-load converters are recommended for use with regulated bus converters in an Intermediate Bus Architecture (IBA). The YNV12T16 non-isolated DC-DC converters deliver output current in an industry-standard, through-hole (SIP) package. They operate from a 9 VDC input and are ideal choices for Intermediate Bus Architectures where point-of-load power delivery is generally a requirement ...

Page 2

... The output voltage should not exceed 5.5 V (taking into account both the programming and remote sense compensation). 2. Note that start-up time is the sum of turn-on delay time and rise time. 3. Converter ON/OFF pin is left open. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet NOTES Continuous By external resistor, See Trim Table 1 Full resistive load From Vin = Vin(min) to Vo=0 ...

Page 3

... Turn-off Threshold Maximum Input Current Input Stand-by Current (Converter disabled) Input No Load Current (Converter enabled) i Input Reflected-Ripple Current - s Input Voltage Ripple Rejection ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet NOTES 16 ADC Out @ 9.6 VDC 5.0 VDC OUT V = 3.3 VDC OUT ...

Page 4

... Settling Time (V < 10% peak deviation) OUT EFFICIENCY Note: 4. See attached waveforms for dynamic response and settling time for different output voltages. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet NOTES MIN Full resistive load From no load to full load V = 0.7525 VDC ...

Page 5

... VDC Input; 0.7525-5.5 VDC Programmable @ 16A Operation Input and Output Impedance The YNV12T16 converter should be connected via a low impedance to the DC power source. In many applications, the inductance associated with the distribution from the power source to the input of the converter can affect the stability of the converter ...

Page 6

... R Required value of trim resistor [k] TRIM  V Desired (trimmed) output voltage [V] REQ O ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet Rw Vout Vin Rload 5 GND Rw Fig. C: Configuration for programming output voltage. Note that the tolerance of a trim resistor directly affects the recommended to use standard ...

Page 7

... ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet Protection Features Input Undervoltage Lockout Input undervoltage lockout is standard with this  kΩ EXT converter. The converter will shut down when the input voltage drops below a pre-determined voltage ...

Page 8

... AWG #40 gauge thermocouples to ensure measurement accuracy. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet Careful routing of the thermocouple leads will further minimize measurement error. Refer to Fig. D for optimum measuring thermocouple location. Thermal Derating Load current vs. ambient temperature and airflow rates are given in Figs. x.1 for maximum temperature of 120 ° ...

Page 9

... IN DC/DC 4x47F Converter ceramic Vsource capacitor Fig. E: Test setup for measuring input reflected ripple i currents, and output voltage ripple. s ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet C 1F O ceramic 100F Vout capacitor ceramic capacitor Page www.power-one.com ...

Page 10

... Vout = 5.0 V converter mounted vertically with air flowing at a rate of 200 LFM (1 m/s) and C. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet 500 LFM (2.5 m/s) 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0 ...

Page 11

... A/div.). Co = 100 μF ceramic. Time scale: 20 μs/div. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet Fig. 5.0V.5: Output voltage ripple (20 mV/div.) at full rated load current into a resistive load with external capacitance 100 μF ceramic and Vin = 12 V for Vout = 5.0 V. Time scale: 2 μ ...

Page 12

... Vout = 3.3 V converter mounted vertically with air flowing at a rate of 200 LFM (1 m/s) and C. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet 500 LFM (2.5 m/s) 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0 ...

Page 13

... A/div.). Co = 100 μF ceramic. Time scale: 20 μs/div. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet Fig. 3.3V.5: Output voltage ripple (20 mV/div.) at full rated load current into a resistive load with external capacitance 100 μF ceramic and Vin = 12 V for Vout = 3.3 V. Time scale: 2 μ ...

Page 14

... Vout = 2.5 V converter mounted vertically with air flowing at a rate of 200 LFM (1 m/s) and C. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet 500 LFM (2.5 m/s) 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0 ...

Page 15

... A/div.). Co = 100 μF ceramic. Time scale: 20 μs/div. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet Fig. 2.5V.5: Output voltage ripple (20 mV/div.) at full rated load current into a resistive load with external capacitance 100 μF ceramic and Vin = 12 V for Vout = 2.5 V. Time scale: 2 μ ...

Page 16

... Vout = 2.0 V converter mounted vertically with air flowing at a rate of 200 LFM (1 m/s) and C. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet 500 LFM (2.5 m/s) 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0 ...

Page 17

... A/div.). Co = 100 μF ceramic. Time scale: 20 μs/div. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet Fig. 2.0V.5: Output voltage ripple (20 mV/div.) at full rated load current into a resistive load with external capacitance 100 μF ceramic and Vin = 12 V for Vout = 2.0 V. Time scale: 2 μ ...

Page 18

... Vout = 1.8 V converter mounted vertically with air flowing at a rate of 200 LFM (1 m/s) and C. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet 500 LFM (2.5 m/s) 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0 ...

Page 19

... A/div.). Co = 100 μF ceramic. Time scale: 20 μs/div. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet Fig. 1.8V.5: Output voltage ripple (20 mV/div.) at full rated load current into a resistive load with external capacitance 100 μF ceramic and Vin = 12 V for Vout = 1.8 V. Time scale: 2 μ ...

Page 20

... Vout = 1.5 V converter mounted vertically with air flowing at a rate of 200 LFM (1 m/s) and C. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet 500 LFM (2.5 m/s) 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0 ...

Page 21

... A/div.). Co = 100 μF ceramic. Time scale: 20 μs/div. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet Fig. 1.5V.5: Output voltage ripple (20 mV/div.) at full rated load current into a resistive load with external capacitance 100 μF ceramic and Vin = 12 V for Vout = 1.5 V. Time scale: 2 μ ...

Page 22

... Vout = 1.2 V converter mounted vertically with air flowing at a rate of 200 LFM (1 m/s) and C. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet 500 LFM (2.5 m/s) 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0 ...

Page 23

... A/div.). Co = 100 μF ceramic. Time scale: 20 μs/div. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet Fig. 1.2V.5: Output voltage ripple (20 mV/div.) at full rated load current into a resistive load with external capacitance 100 μF ceramic and Vin = 12 V for Vout = 1.2 V. Time scale: 2 μ ...

Page 24

... Vout = 1.0 V converter mounted vertically with air flowing at a rate of 200 LFM (1 m/s) and C. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet 500 LFM (2.5 m/s) 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0 ...

Page 25

... A/div.). Co = 100 μF ceramic. Time scale: 20 μs/div. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet Fig. 1.0V.5: Output voltage ripple (20 mV/div.) at full rated load current into a resistive load with external capacitance 100 μF ceramic and Vin = 12 V for Vout = 1.0 V. Time scale: 2 μ ...

Page 26

... Vout = 0.7525 V converter mounted vertically with air flowing at a rate of 200 LFM (1 m/s) and C. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet 500 LFM (2.5 m/s) 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0 ...

Page 27

... A/div.). Co = 100 μF ceramic. Time scale: 20 μs/div. ZD-02039 Rev. 3.2, 24-Jun-10 YNV12T16 DC-DC Converter Data Sheet Fig. 0.7525V.5: Output voltage ripple (20 mV/div.) at full rated load current into a resistive load with external capacitance 100 μF ceramic and Vin = 12 V for Vout = 0.7525 V. Time scale: 2 μ ...

Page 28

... VDC Hole (SIP) The example above describes P/N YNV12T16-0: 9.6 V – input, through-hole (SIP 0.7525 V to 5.5 V output, standard enable logic, and the RoHS lead-solder-exemption feature. Please consult factory regarding availability of a specific version. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc ...