GS-R415 STMicroelectronics, GS-R415 Datasheet - Page 4

IC REG SW STEP DOWN 4A 15V

GS-R415

Manufacturer Part Number
GS-R415
Description
IC REG SW STEP DOWN 4A 15V
Manufacturer
STMicroelectronics
Series
GS-R400r
Type
Point of Load (POL) Non-Isolatedr
Datasheet

Specifications of GS-R415

Output
15V
Number Of Outputs
1
Power (watts)
60W
Mounting Type
Through Hole
Voltage - Input
19 ~ 46V
Package / Case
Module
1st Output
15 VDC @ 4A
Size / Dimension
3.37" L x 2.64" W x 0.84" H (85.5mm x 67mm x 21.3mm)
Power (watts) - Rated
60W
Operating Temperature
-20°C ~ 85°C
Efficiency
85%
Output Voltage
15 V
Output Current
4 A
Input Voltage
19 V to 46 V
Switching Frequency
100 KHz
Operating Temperature Range
- 20 C to + 85 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
497-8274
GS-R415

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
GS-R415
Manufacturer:
STMicroelectronics
Quantity:
135
Figure 2. Remote Inhibit Operation
V
Current Limiting Programming
The GS-R400VB current limiting is programmed by
using a resistor (see pin function table and fig. 4).
is a limitation, a 22 F ceramic multilayer capacitor
must be connected to the module input pins.
Output Voltage Programming
The GS-R400V and GS-R400VB output voltage is
programmed by using a resistor (see pin function
table and fig. 4). The resistor must be located very
close the module and the PCB layout must
mimimize injected noise. The value of the resistor
is calculated by using the following formula:
Figure 1. Load Connection
GS-R400 FAMILY
4/5
o
can be adjusted between 5.1 and 40V.
R
v
2.67
5.1
V
o
–1 k
Figure 3. Reset Operation
The value of the resistor is calculated by using the
following formula:
Module Protection
The modules are protected against occasional and
permanent short circuits of the output pin to ground,
as well as against output current overload.
When the output current exceeds the maximum
value, the output is automatically disabled. After a
fixed time the module starts again in a soft mode.
The cycle is repeated until the overload condition is
removed.
A crowbar output overvoltage protection is activated
whenever the output voltage exceeds the nominal
output voltage by more than 25%.
R
i
= [2.2 + (5 I
o
)] k

Related parts for GS-R415