EXB100-48S1V8 Emerson Network Power, EXB100-48S1V8 Datasheet - Page 2

no-image

EXB100-48S1V8

Manufacturer Part Number
EXB100-48S1V8
Description
CONV DC/DC OPN FRM 1.8V OUT 100W
Manufacturer
Emerson Network Power
Series
EXB100r
Type
Isolatedr
Datasheet

Specifications of EXB100-48S1V8

Rohs Status
RoHS non-compliant
Mfg Application Notes
EXB100 Singles Application Notes
Output
1.8V
Number Of Outputs
1
Power (watts)
100W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module (8 Leads), 1/2 Brick
1st Output
1.8 VDC @ 30A
Size / Dimension
2.40" L x 2.28" W x 0.39" H (61mm x 57.9mm x 10mm)
Power (watts) - Rated
54W
Operating Temperature
-40°C ~ 90°C
Efficiency
87.5%
Approvals
cUL, TUV, UL
3rd Output
-
2nd Output
-
4th Output
-
EXB100 Series
Notes
1
2
3
4
5
6
7
8
9
International Safety Standard Approvals
TÜV
PIN NUMBER
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Please consult our website for the following items:
DC/DC CONVERTERS
Data Sheet © Artesyn Technologies® 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
OUTPUT
POWER
(MAX.)
Measured as per recommended set-up. See Application Note 129 for details.
di/dt = 0.1A/µs, Vin = 48VDC, Tc = 25°C, load change = 0.5 lo max. to 0.75
lo max. and 0.75 lo max. to 0.5 lo max.
Recommended input fusing is a 5A HRC 200V rated fuse.
Measured with external filter. See Application Note 129 for details.
Signal line assumed <3m in length.
Start-up into resistive load.
The EXB100 meets levels A and B conducted emissions with external
components. See Application Note 129 for details.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Negative remote ON/OFF option also available. Add suffix ‘-R’ to part
number, for example EXB100-48S3V3-R.
100W
100W
54W
1
2
3
4
5
6
7
8
9
PIN CONNECTIONS
UL/cUL CAN/CSA 22.2 No. 60950-00 : UL 60950
File No. E174104
TÜV Product Service. Certificate No. B 02 02 38572 031
36-75VDC
36-75VDC
36-75VDC
VOLTAGE
INPUT
Remote ON/OFF
FUNCTION
+Sense
-Sense
No Pin
+Vout
-Vout
+Vin
Trim
-Vin
S i n g l e o u t p u t
54-100W DC/DC Isolated Converters
6.0VDC
3.9VDC
2.2VDC
OVP
VOLTAGE
OUTPUT
5.0V
3.3V
1.8V
CURRENT
OUTPUT
(MIN.)
Application Note
0A
0A
0A
CURRENT
OUTPUT
(MAX.)
20A
30A
30A
PROTECTION
Short circuit protection
Overvoltage protection
TELECOM SPECIFICATION
Central office interface A
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
Max open-frame
converter height
Longform Data Sheet
EFFICIENCY
ON/OFF
Remote
Minimum clearance from
seating plane to
underside components
91.5%
90.5%
87.5%
Vin+
(TYP.)
Vin-
Ø0.040 0.002
(Ø1.02 0.05)
6 Places
2.280 0.02
(57.91 0.5)
±0.2%
±0.2%
±0.2%
(48.26)
1.900
LINE
REGULATION
Ø0.080 0.002
(Ø2.03 0.05)
File Name: EXB100S.PDF Rev: 29 March 2002
2 Places
±0.4%
±0.4%
±0.4%
LOAD
ETS300-132-2 input voltage
www.artesyn.com
All dimensions in inches (mm)
General tolerance 0.01in ( 0.25mm)
except where specified otherwise
and current requirements
NEW Product
Sense+
Sense-
Trim
Vo-
Vo+
Bottom View
Non-latching clamp
seating plane
EXB100-48S3V3
EXB100-48S1V8
EXB100-48S05
NUMBER
MODEL
Continuous
(9)
2

Related parts for EXB100-48S1V8