EXB100-48S05-R Emerson Network Power, EXB100-48S05-R Datasheet

no-image

EXB100-48S05-R

Manufacturer Part Number
EXB100-48S05-R
Description
CONV DC/DC 5V OUT 100W REMOTE
Manufacturer
Emerson Network Power
Series
EXB100r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of EXB100-48S05-R

Rohs Status
RoHS non-compliant
Mfg Application Notes
EXB100 Singles Application Notes
Output
5V
Number Of Outputs
1
Power (watts)
100W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module (8 Leads), 1/2 Brick
1st Output
5 VDC @ 20A
Size / Dimension
2.40" L x 2.28" W x 0.39" H (61mm x 57.9mm x 10mm)
Power (watts) - Rated
100W
Operating Temperature
-40°C ~ 90°C
Efficiency
91.5%
Approvals
cUL, TUV, UL
3rd Output
-
2nd Output
-
4th Output
-
EXB100 Series
The EXB100 series of 100W single output isolated DC/DC converters are specially
designed to meet the power needs of low voltage silicon. Housed in an open-frame
package with standard footprint, these latest generation converters offer efficiencies as
high as 91.5% (typical on 5V at 20A). The series comprises three 48V input models with
5V, 3.3V and 1.8V outputs. All models feature a wide input range, trimmable output
voltage and 30A output (5V is limited to 20A). Remote sense and remote ON/OFF
facilities are included as standard, and the converters are comprehensively protected
against over-current, over-voltage and over-temperature conditions.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
DC/DC CONVERTERS
OUTPUT SPECIFICATIONS
Voltage adjustability
Output setpoint accuracy
Line regulation
Load regulation
Total error band
Minimum load
Overshoot
Undershoot
Ripple and noise
5Hz to 20MHz
Transient response
(See Note 2)
INPUT SPECIFICATIONS
Input voltage range
Input current
Input current (max.)
Input reflected ripple
Remote ON/OFF
Logic compatibility
ON
OFF
Under-voltage lockout
Start-up time
(See Note 6)
Ultra wide trim range, 60% to 110% (1.08V to 5.5V)
High efficiency, 91.5% @ 5V, 90.5% @ 3.3V, 87.5% @ 1.8V
Basic insulation (input to output)
Industry standard half-brick pin-out
No minimum load
Over-voltage and over-temperature protection
Remote ON/OFF
Low line to high line
Full load to min. load
At turn-on and turn-off
(See Note 1)
Deviation
No load
Remote OFF
(See Note 3)
(See Note 4)
Power up
Power down
Power up
Remote ON/OFF
S i n g l e o u t p u t
54-100W DC/DC Isolated Converters
Open collector ref to -input
within total error band
3.15A max. @ Io max.
and Vin = 36 to 75V
300µs recovery to
60% to 110%
100mV pk-pk
60mA (pk-pk)
36 to 75VDC
(See Note 5)
±0.2% max.
±0.4% max.
50mV rms
<1.2VDC
>2VDC
150mV
150mA
20mA
40ms
35ms
1.5%
3.0%
None
None
36V
30V
0%
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
Immunity:
ESD air
ESD contact
Radiated field enclosure EN61000-4-3 10V/m
Conducted (DC power)
Conducted (signal)
Input transients
GENERAL SPECIFICATIONS
Efficiency
Basic insulation
Switching frequency
(Fixed)
Approvals and
standards (See Note 8)
Material flammability
Weight
MTBF
Representative model:
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Altitude derating
(above sea level)
EN55022 (See Note 7)
EN55022 (See Note 7)
EN55022
(See Long Form Data Sheet)
EN61000-4-2 8kV, 15kV
EN61000-4-2 6kV, 8kV
EN61000-4-6 10V
EN61000-4-6 10V
ETS 300 132-2, ETR 283
Input/output
5V
3.3V, 1.8V
MIL-HDBK-217F
1V8 @ 48Vin, 40ºC
100% load, ground benign
BELLCORE 332
Operating ambient.
temperature
Non-operating
3,000m
10,000m
File Name: EXB100S.PDF Rev: 29 March 2002
SPECIFICATIONS
NEW Product
TÜV Product Service
2 YEAR WARRANTY
-40°C to +125°C
-40°C to +90°C
115,000 hours
591,000 hours
UL/cUL60950
(See Note 5)
45g (1.59oz)
300kHz typ.
220kHz typ.
See table
1500VDC
UL94V-0
Level A
Level B
Level A
TÜV
20%
50%
1

Related parts for EXB100-48S05-R

EXB100-48S05-R Summary of contents

Page 1

... Over-voltage and over-temperature protection • Remote ON/OFF The EXB100 series of 100W single output isolated DC/DC converters are specially designed to meet the power needs of low voltage silicon. Housed in an open-frame package with standard footprint, these latest generation converters offer efficiencies as high as 91.5% (typical 20A). The series comprises three 48V input models with 5V, 3 ...

Page 2

... Signal line assumed <3m in length. 6 Start-up into resistive load. 7 The EXB100 meets levels A and B conducted emissions with external components. See Application Note 129 for details. 8 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. ...

Related keywords