24H1601-2R POWER ONE, 24H1601-2R Datasheet - Page 13

no-image

24H1601-2R

Manufacturer Part Number
24H1601-2R
Description
CONV DC-DC 50W 24VDC CASSETTE
Manufacturer
POWER ONE
Series
Hr
Type
Isolatedr
Datasheet

Specifications of 24H1601-2R

Output
24V
Number Of Outputs
1
Power (watts)
50W
Mounting Type
Surface Mount
Voltage - Input
14 ~ 30V
Package / Case
Module
1st Output
24 VDC @ 2A
Size / Dimension
6.63" L x 4.38" W x 1.52" H (168.5mm x 111.2mm x 38.7mm)
Power (watts) - Rated
50W
Operating Temperature
-10°C ~ 50°C
Efficiency
83%
Approvals
CE, cUL, TUV, UL
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
Q1166581
Installation Instructions
The H series DC-DC converters are components, intended
exclusively for inclusion within other equipment by an
industrial assembly operation or by professional installers.
Installation must strictly follow the national safety
regulations in compliance with the enclosure, mounting,
creepage, clearance, casualty, markings, and segregation
requirements of the end-use application. See also:
Technical Information: Installation and Application.
Connection to the system shall be made via the female
connector H11 (see: Accessories ) . Other installation
methods may not meet the safety requirements.
All DC-DC converters are provided with pin no. 26 ( ),
which is reliably connected with their case. For safety
reasons it is essential to connect this pin with the protective
earth of the supply system if required in: Safety of operator
accessible output circuit .
Ensure that a cassette failure (e.g. by an internal short-
circuit) does not result in a hazardous condition. See also:
Safety of operator accessible output circuit.
To prevent excessive current flowing into the cassette (e.g.
by an internal short-circuit), an external fuse suitable for the
application and in compliance with the local requirements
should be installed in the wiring to one or both input pins
(no. 29 and/or no. 32). See also: Input Fuse .
Make sure that there is sufficient airflow possible for
convection cooling. This should be verified by measuring
the case temperature when the unit is installed and
operated in the end-use application. The maximum
specified case temperature T
See also: Thermal Considerations.
If the end-product is to be UL certified, the temperature of
the main isolation transformer should be evaluated as part
of the end-product investigation.
Table 14: Isolation
1
2
For creepage distances and clearances refer to: Technical Information: Safety.
REV. MAR 27, 2006
Characteristic
Electric
strength
test voltage
Insulation resistance at 500 VDC
Important: Whenever the inhibit function is not in use,
pin no. 2 (i) should be connected to pin no. 23 (Vo1–) to
enable the output(s).
Do not open the modules, or guarantee will be
invalidated.
In accordance with IEC/EN 60950 only subassemblies are tested in factory with this voltage.
Tested at 300 VDC.
Required according to
IEC/EN 60950
Actual factory test 1 s
AC test voltage equivalent
to actual factory test
C max
shall not be exceeded.
Input to
>300
case
1.5
2.1
2.8
2.0
Input to
output
>300
3.0
4.2
5.6
4.0
Page 13 of 19
1
1
1
1
to case
Output
Cleaning Agents
In order to avoid possible damage, any penetration of
liquids (e.g. cleaning fluids) is to be prevented, since the
power supplies are not hermetically sealed.
Standards and Approvals
12H to 48H DC-DC converters correspond to class I
equipment. All types are UL recognized according to UL
1950, UL recognized for Canada to CAN/CSA C22.2 No.
950-95 and TÜV approved to IEC/EN 60950 standards.
The units have been evaluated for:
• Building in
• Supplementary insulation between input and case and
• Operational insulation between output(s) and case
• Operational insulation between the outputs
• The use in a pollution degree 2 environment
• Connecting the input to a primary or secondary circuit
The DC-DC converters are subject to manufacturing
surveillance in accordance with the above mentioned UL,
CSA, EN and with ISO 9001 standards.
Protection Degree
Condition: Female connector fitted to the unit.
IP 40:
potentiometer.
IP 20:
potentiometer.
Isolation
The electric strength test is performed as a factory test in
accordance with IEC/EN 60950 and UL 1950 and should
not be repeated in the field. Power-One will not honor any
guarantee/warranty claims resulting from electric strength
field tests.
>300
0.5
0.7
1.4
1.0
double or reinforced insulation between input and
output, based on 250 VAC and 400 VDC
with a maximum transient rating of 2500 V.
50 Watt DC-DC Cassette Converters
to output
All units, except those with option D or V with
All units fitted with option D or V with
Output
>100
0.3
0.2
-
-
2
kVDC
kV
kV
Unit
rms
rms
H Series Data Sheet
www.power-one.com