JAHW050F1 Lineage Power, JAHW050F1 Datasheet - Page 7

no-image

JAHW050F1

Manufacturer Part Number
JAHW050F1
Description
CONVERTER DC/DC 3.3V 33W OUT
Manufacturer
Lineage Power
Series
JAHWr
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JAHW050F1

Output
3.3V
Number Of Outputs
1
Power (watts)
33W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
3.3 VDC @ 10A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
33W
Operating Temperature
-40°C ~ 100°C
Efficiency
88%
Approvals
CE, CSA, UL, VDE
Product
Isolated
Output Power
33 W
Input Voltage Range
36 V to 75 V
Output Voltage (channel 1)
3.3 V
Output Current (channel 1)
10 A
Isolation Voltage
1.5 KV
Package / Case Size
DIP
Output Type
Isolated
Output Voltage
3.3 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JAHW050F1
Manufacturer:
TYCO
Quantity:
27
Part Number:
JAHW050F1
Manufacturer:
VICOR
Quantity:
560
April 2008
Characteristic Curves
Note: Tested with a 10 µF aluminum and a 1.0 µF tantalum capacitor
Figure 9. Typical JAHW050F Transient Response to
Note: Tested with a 10 µF aluminum and a 1.0 µF tantalum capacitor
Figure 10. Typical JAHW075F Transient Response
Lineage Power
3.75 A
across the load.
across the load.
2.5 A
Step Decrease in Load from 50% to 25%
of Full Load at Room Temperature and
48 Vdc Input (Waveform Averaged to
Eliminate Ripple Component.)
to Step Decrease in Load from 50% to
25% of Full Load at Room Temperature
and 48 Vdc Input (Waveform Averaged
to Eliminate Ripple Component.)
TIME, t (50 μs/div)
TIME, t (100 μs/div)
(continued)
dc-dc Converters; 36 to 75 Vdc Input, 3.3 Output; 33 W to 66 W
8-2378 (F)
8-2294 (F)
Note: Tested with a 10 µF aluminum and a 1.0 µF tantalum capacitor
Figure 11. Typical JAHW100F Transient Response
Note: Tested with a 10 µF aluminum and a 1.0 µF tantalum capacitor
Figure 12. Typical JAHW050F Transient Response
5 A
10 A
across the load.
across the load.
5 A
to Step Decrease in Load from 50% to
25% of Full Load at Room Temperature
and 48 Vdc Input (Waveform Averaged
to Eliminate Ripple Component.)
to Step Increase in Load from 50% to
75% of Full Load at Room Temperature
and 48 Vdc Input (Waveform Averaged
to Eliminate Ripple Component.)
TIME, t (50 μs/div)
TIME, t (50 μs/div)
8-2487 (F)
8-2379 (F)
7

Related parts for JAHW050F1