JAHW050F1 Lineage Power, JAHW050F1 Datasheet - Page 12

no-image

JAHW050F1

Manufacturer Part Number
JAHW050F1
Description
CONVERTER DC/DC 3.3V 33W OUT
Manufacturer
Lineage Power
Series
JAHWr
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JAHW050F1

Output
3.3V
Number Of Outputs
1
Power (watts)
33W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
3.3 VDC @ 10A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
33W
Operating Temperature
-40°C ~ 100°C
Efficiency
88%
Approvals
CE, CSA, UL, VDE
Product
Isolated
Output Power
33 W
Input Voltage Range
36 V to 75 V
Output Voltage (channel 1)
3.3 V
Output Current (channel 1)
10 A
Isolation Voltage
1.5 KV
Package / Case Size
DIP
Output Type
Isolated
Output Voltage
3.3 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JAHW050F1
Manufacturer:
TYCO
Quantity:
27
Part Number:
JAHW050F1
Manufacturer:
VICOR
Quantity:
560
dc-dc Converters; 36 to 75 Vdc Input, 3.3 Output; 33 W to 66 W
Feature Descriptions
Output Voltage Set-Point Adjustment
(Trim)
Figure 21. Circuit Configuration to Decrease
Figure 22. Circuit Configuration to Increase
Output Overvoltage Protection
To provide protection in an output overvoltage condi-
tion, the unit is equipped with circuitry that moonitors
the voltage on the ouput terminals. If the voltage on the
output terminals exceed the overvoltage protection
threshold, the module enters a hiccup mode of opera-
tion whereby it shuts down and automaticall attempts
to restart. As long as the fault persists, the module
remains in this mode.
The protection mechanism is such that the unit can
continue in this condition until the fault is cleared.
A latch-off option is also available.*
12
12
*Protection latch-off causes the ouput to be disabled until input
power is recyeled or until the remote on-off is recycled off-on.
V
ON/OFF
CASE
V
V
ON/OFF
CASE
V
I
I
I
I
(+)
(–)
(+)
(–)
(continued)
Output Voltage
Output Voltage
SENSE(+)
SENSE(+)
SENSE(–)
SENSE(–)
V
V
TRIM
V
TRIM
V
O
O
O
O
(+)
(+)
(–)
(–)
(continued)
R
R
adj-up
adj-down
R
R
LOAD
LOAD
8-748 (F).b
8-715 (F).b
Overtemperature Protection
To provide protection in a overtemperature condition,
the unit is equipped with an overtemperature circuit. In
the event of such a fault, the module enters into a hic-
cup mode of operation whereby it shuts down and
automatically attempts to restart. As long as the fault
persists, the module remains in this mode.
The protection mechanism is such that the unit can
continue in this condition until the fault is cleared.
A latcho-off option is also available.*
Thermal Considerations
Introduction
The power modules operate in a variety of thermal
environments; however, sufficient cooling should be
provided to help ensure reliable operation of the unit.
Heat-dissipating components inside the unit are ther-
mally coupled to the case. Heat is removed by conduc-
tion, convection, and radiation to the surrounding
environment. Proper cooling can be verified by mea-
suring the case temperature. Peak temperature (T
occurs at the position indicated in Figure 23.
Note: Top view, pin locations are for reference only. Measurements
Figure 23. Case Temperature Measurement
The temperature at this location should not exceed
100 °C. The output power of the module should not
exceed the rated power for the module as listed in the
Ordering Information table.
Although the maximum case temperature of the power
modules is 100 °C, you can limit this temperature to a
lower value for extremely high reliability.
(1.20)
shown in millimeters and (inches).
30.5
Location
V
ON/OFF
CASE
V
(1.14)
I
I
(+)
(–)
29.0
+ SEN
– SEN
V
TRIM
V
O
O
(+)
(–)
MEASURE CASE
TEMPERATURE HERE
Lineage Power
April 2008
8-716 (F).h
C
)