CC30-2405SFH-E TDK Corporation, CC30-2405SFH-E Datasheet - Page 6

CONV DC/DC 24V 5V 6A 30W PCB

CC30-2405SFH-E

Manufacturer Part Number
CC30-2405SFH-E
Description
CONV DC/DC 24V 5V 6A 30W PCB
Manufacturer
TDK Corporation
Series
CC-P-Er
Type
Isolatedr

Specifications of CC30-2405SFH-E

Output
5V
Number Of Outputs
1
Power (watts)
30W
Mounting Type
Through Hole
Voltage - Input
24V
Package / Case
20-DIP Module (17 Leads)
1st Output
5 VDC @ 6A
Size / Dimension
1.51" L x 1.32" W x 0.33" H (38.4mm x 33.5mm x 8.3mm)
Power (watts) - Rated
30W
Operating Temperature
-40°C ~ 85°C
Efficiency
89%
Approvals
CSA, cUL, EN, UL
Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
18V To 36V
Power Rating
30W
Output Voltage
5V
Output Current
6A
Approval Bodies
CULus, CSA
Supply Voltage
24V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
4-2 Alarm (ALM Terminal)
By means of the ALM terminal the presence / absence of an abnormal state can be monitored.
When not using the alarm output function, set the ALM terminal in the open condition.
4-3 Simultaneous Start-Up / Stop (PO Terminal)
By means of the PO terminal, the start-up / stop timing of multiple converter units can be synchronized.
To do so, connect the PO terminals to each other.
When not using the simultaneous start-up / stop function, set the PO terminal in the open position.
※Contact TDK-Lambda concerning items not mentioned or items which are not clear.
When the output turns OFF as a result of over-current protection, low-voltage protection, over-voltage protection, the
Alarm Signal will operate. At that time, the ALM terminal voltage is L level (the –Vin terminal is 0.3V or less).
When multiple units are operated in series or in parallel, etc., and the ALM terminals are connected together, when an
abnormality occurs and the alarm signal operates in 1 unit, the other connected units can be stopped.
Converters having different output voltages can be connected. (This applies only to converters belonging to this series).
Use the ALM terminal at a maximum sink current of 10mA.
The maximum number of units to which the ALM terminal can be connected is 20 units.
Converters having different output voltages can be connected. (This applies only to converters belonging to this series).
The maximum number of units to which the PO terminal can be connected is 20 units.
Fig. 4-2 Alarm Terminal Internal Circuit
Sink current
10mA(max)
-Vin
ALM
(typ)
8V