NHD-0416B1Z-FSPG-YBW-L-3V Newhaven Display, NHD-0416B1Z-FSPG-YBW-L-3V Datasheet

LCD MOD CHAR 4X16 Y/G TRANSFL

NHD-0416B1Z-FSPG-YBW-L-3V

Manufacturer Part Number
NHD-0416B1Z-FSPG-YBW-L-3V
Description
LCD MOD CHAR 4X16 Y/G TRANSFL
Manufacturer
Newhaven Display
Series
NHD-0416B1Z-Fr

Specifications of NHD-0416B1Z-FSPG-YBW-L-3V

Display Type
STN - Super-Twisted Nematic
Display Mode
Transflective
Number Of Digits/alpha
64
Outline L X W X H
87.00mm x 60.00mm x 14.00mm
Viewing Area
61.80mm L x 25.20mm W
Backlight
LED - Green
Display Format
16 x 4
Character Size
4.75mm H x 2.95mm W
Character Format
5 x 8 Dots
Voltage - Supply
5.0V
Dot Size
0.55mm W x 0.55mm H
Operating Temperature
-20°C ~ 70°C
Character Count X Line
16 x 4
Module Size (w X H X T)
87 mm x 60 mm x 13.5 mm
Features
Low Power Backlight
Fluid Type
STN
Background Color
Pure Green
Voltage Rating
3 V
Operating Temperature Range
- 20 C to + 70 C
Backlight Type
LED Yellow-Green
Interface
Parallel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NHD-0416B1Z-FSPG-YBW-L-3V
Manufacturer:
Newhaven Display
Quantity:
135
User’s Guide
NHD-0416B1Z-FSPG-YBW-L3V
L3V- Low Power (20mA) 3
NHD-
0416-
B1Z-
F-
SPG-
Y-
B-
W-
LCM
(Liquid Crystal Display Module)
RoHS Compliant
Newhaven Display
4 Lines x 16 Characters
Version Line
Transflective
Side Pure Green LED B/L
STN-Yellow/Green
6:00 View
Wide Temperature (-20 ~ +70c)
.3 volts
For product support, contact
Newhaven Display International
2511 Technology Drive, #101
Elgin, IL 60124
Tel: (847) 844-8795 Fax: (847) 844-8796
F ebruary 29, 2008

Related parts for NHD-0416B1Z-FSPG-YBW-L-3V

NHD-0416B1Z-FSPG-YBW-L-3V Summary of contents

Page 1

... User’s Guide NHD-0416B1Z-FSPG-YBW-L3V LCM (Liquid Crystal Display Module) RoHS Compliant NHD- Newhaven Display 0416- 4 Lines x 16 Characters B1Z- Version Line F- Transflective SPG- Side Pure Green LED B/L Y- STN-Yellow/Green B- 6:00 View W- Wide Temperature (-20 ~ +70c) L3V- Low Power (20mA volts For product support, contact ...

Page 2

... NHD-0416B1Z DOCUMENT REVISION HISTORY Version DATE 00 NOV-05-2005 CONTENTS Item Functions & Features Mechanical specifications Dimensional Outline Absolute maximum ratings Block diagram Pin description Contrast adjust Optical characteristics Electrical characteristics Timing Characteristics Instruction description Display character address code: character pattern Quality Specifications ...

Page 3

... NHD-0416B1Z 1.Features 1. 5x8 dots with cursor 2. Built-in controller (KS0066U or equivalent) 3. +3.3V power supply 4. 1/16 duty cycle;1/5bias 5. BKL to be driven by pin1, pin2, or pin15, pin16 16characters *4lines display LCD type FSTN positive STN Yellow Green View direction 6 O’clock Rear Polarizer Reflective Backlight Type ...

Page 4

...

Page 5

Absolute maximum ratings Item Power voltage Input voltage Operating temperature range Storage temperature range 5. Block diagram 6.Interface pin description Pin no. Symbol connection Power supply R/W ...

Page 6

... NHD-0416B1Z 7. Contrast adjust V : LCD Driving voltage V DD~ 0 VR: 10k~20k 8. Optical characteristics TN type display module (Ta=25 , VDD=3.3V) Item Symbol Viewing angle Contrast ratio Response time (rise) Response time (fall) STN type display module (Ta=25 , VDD=3.3V) Item Symbol Viewing angle Contrast ratio Response time (rise) Response time (fall) 9 ...

Page 7

... NHD-0416B1Z 10. Timing Characteristics Write cycle (Ta=25 , VDD=3.V) Parameter Symbol Enable cycle time t c Enable pulse width t w Enable rise/fall time RS; R/W setup time t su1 RS; R/W address hold t h1 time Read data output delay t su2 Read data hold time t h2 Write mode timing diagram ...

Page 8

... NHD-0416B1Z Read cycle (Ta=25 , VDD=3.3V) Parameter Symbol Enable cycle time t c Enable pulse width t w Enable rise/fall time RS; R/W setup time t su RS; R/W address hold t h time Read data output delay t d Read data hold time t dh Read mode timing diagram ...

Page 9

... NHD-0416B1Z 11. Instruction description 11.1Outline To overcome the speed difference between the internal clock of KS0066U and the MPU clock, KS0066U performs internal operations by storing control in formations DR. The internal operation is determined according to the signal from MPU, composed of read/write and data bus (Refer to Table7). Instructions can be divided largely into four groups: 1) KS0066U function set instructions (set display methods, set data length, etc ...

Page 10

... NHD-0416B1Z From RAM NOTE: When an MPU program with checking the busy flag (DB7) is made, it must be necessary 1/2fosc is necessary for executing the next instruction by the falling edge of the “E” signal after the busy flag (DB7) goes to “Low”. 11.3Contents 1) Clear display ...

Page 11

... NHD-0416B1Z RS R/W DB7 Shifting of right/left cursor position or display without writing or reading of display data. This instruction is used to correct or search display data. During 2-line mode display, cursor moves to the 2nd line after the 40th digit of the 1st line. Note that display shift is performed simultaneously in all the lines. ...

Page 12

... NHD-0416B1Z 10) Write data to RAM RS R/W DB7 Write binary 8-bit data to DDRAM/CGRAM. The selection of RAM from DDRAM, and CGRAM, is set by the previous address set instruction (DDRAM address set, CGRAM address set). RAM set instruction can also determine the AC direction to RAM. After write operation. The address is automatically increased/decreased by 1, according to the entry mode. ...

Page 13

... NHD-0416B1Z 13. Standard character pattern Newhaven Display 13 ...

Page 14

... NHD-0416B1Z 14. QUALITY SPECIFICATIONS 14.1 Standard of the product appearance test Manner of appearance test: The inspection should be performed in using 20W x 2 fluorescent lamps. Distance between LCM and fluorescent lamps should be 100 cm or more. Distance between LCM and inspector eyes should more. Viewing direction for inspection is 45° from vertical against LCM. ...

Page 15

... NHD-0416B1Z 14.2 Specification of quality assurance AQL inspection standard Sampling method: MIL-STD-105E, Level II, single sampling Defect classification (Note not including) Classify Major Display state Non-display Minor Display state Polarizer Soldering Wire TAB Newhaven Display Item Short or open circuit LC leakage Flickering No display Wrong viewing direction ...

Page 16

... NHD-0416B1Z Note on defect classification No. Item 1 Short or open circuit LC leakage Flickering No display Wrong viewing direction Wrong Back-light 2 Contrast defect Background color deviation 3 Point defect, Black spot, dust (including Polarizer) = (X+Y)/2 Line defect, 4 Scratch 5 Rainbow Newhaven Display Criterion Not allow Refer to approval sample ...

Page 17

... NHD-0416B1Z No Item 6 Chip Remark: X: Length direction Y: Short direction Z: Thickness direction t: Glass thickness W: Terminal Width Y W Criterion Acceptable criterion Acceptable criterion Acceptable criterion shall not reach to ITO X Acceptable criterion Y Disregard Z X Acceptable criterion Newhaven Display 0.5mm 0.5mm 0 t/3 ...

Page 18

... NHD-0416B1Z No. Item 7 Segment pattern W = Segment width = (X+Y)/2 8 Back-light 9 Soldering 10 Wire 11* PCB Newhaven Display Criterion (1) Pin hole < 0.10mm is acceptable Point Size (1) The color of backlight should correspond its specification. (2) Not allow flickering (1) Not allow heavy dirty and solder ball on PCB. (The size of dirty refer to point and dust defect) (2) Over 50% of lead should be soldered on Land ...

Page 19

... NHD-0416B1Z No Item 12 Protruded W: Terminal Width 13 TAB 1. Position 2 TAB bonding strength test 14 Total no. of acceptable A. Zone Defect B. Zone Criterion TAB P (=F/TAB bonding width) 650gf/cm ,(speed rate: 1mm/min) 5pcs per SOA (shipment) Maximum 2 minor non-conformities per one unit. Defect distance: each point to be separated over 10mm It is acceptable when trouble for quality and assembly in customer’ ...

Page 20

... NHD-0416B1Z 14.3 Reliability of LCM Reliability test condition: Item High temp. Storage High temp. Operating Low temp. Storage Low temp. Operating Humidity Temp. Cycle Recovery time should be 24 hours minimum. Moreover, functions, performance and appearance shall be free from remarkable deterioration within 50,000 hours under ordinary operating and storage conditions room temperature (20+8 C), normal humidity (below 65% RH), and in the area not exposed to direct sun light ...

Page 21

... NHD-0416B1Z 3. Do not touch the connection terminals of the display with bare hand; it will cause disconnection or defective insulation of terminals. 4. The modules should be kept in anti-static bags or other containers resistant to static for storage. 5. Only properly grounded soldering irons should be used electric screwdriver is used, it should be grounded and shielded to prevent sparks ...

Related keywords