EXII-7719UC 3M, EXII-7719UC Datasheet - Page 23

CONTROLLER EXII USB 1X2 CAPAC

EXII-7719UC

Manufacturer Part Number
EXII-7719UC
Description
CONTROLLER EXII USB 1X2 CAPAC
Manufacturer
3M
Series
MicroTouch™ Controller EXr
Datasheets

Specifications of EXII-7719UC

Accessory Type
Touch Screen - Controller
Operating Supply Voltage
5 VDC
Resolution
16 K x 16 K
For Use With/related Products
ClearTek™ Touch Screens
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
3M5766
98-0003-1996-6
3M™ MicroTouch™ Controller EX USB Reference Guide
Reset Request 7
Table 13. Extended POC Status
This is a request to perform a controller reset. The standard hard or soft reset can be
requested. Soft resets are generally required for any parameter changes to take effect. A
soft reset results in the touch application using its initial (start-up) values.
Table 14. Reset Request
The direction bit in bmRequestType has been set to 0 (host-to-device).
The byte bRequest is set to 7 to indicate that this is a Reset request.
The wValue field is used to select the type of reset to be performed -- 1 for Soft Reset
and 2 for Hard Reset.
The wIndex field is not used. This field should be set to zero to ensure future
compatibility.
The wLength field is set to zero since there is no data phase for this request.
Response
Since the time to complete the soft reset can be more than 500 ms, the device
acknowledges the request before it is completed. The host must issue a status request to
determine whether the reset request was completed. The command status field of the
status report will be set to “command in progress” while the soft reset is occurring. The
field will change to “soft reset occurred” when the reset has completed. Any other request
issued while the reset is still in progress will be ignored.
The hard reset is executed immediately upon decoding of this request. The reset sequence
begins by simulating a device disconnect from the host. A re-connect is then performed
and the device must re-enumerate its connection with the host. Because of this, a
response to the request cannot be sent prior to, or even after, the beginning of the reset
sequence.
Bit Number
0
1
2 - 15
Offset
0
1
2
4
6
Field
bmRequestType
bRequest
wValue
wIndex
wLength
3M Touch Systems, Inc. Proprietary Information
Description
Corner drive offset level is too high
Fixed 2-point calibration error high
Reserved
Size
1
1
2
2
2
Value
01000000
7
0xXXXX
0x0000
0x0000
Description
Characteristics
Command number
Reset type
Not used
No data phase
23