EXII-7719UC 3M, EXII-7719UC Datasheet - Page 19

CONTROLLER EXII USB 1X2 CAPAC

EXII-7719UC

Manufacturer Part Number
EXII-7719UC
Description
CONTROLLER EXII USB 1X2 CAPAC
Manufacturer
3M
Series
MicroTouch™ Controller EXr
Datasheets

Specifications of EXII-7719UC

Accessory Type
Touch Screen - Controller
Operating Supply Voltage
5 VDC
Resolution
16 K x 16 K
For Use With/related Products
ClearTek™ Touch Screens
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
3M5766
98-0003-1996-6
3M™ MicroTouch™ Controller EX USB Reference Guide
Calibration Request 4
Operating Mode
The operating mode specifies the conditions under which the controller sends the X and
Y touch coordinates (input data packet) to the host system.
Report 1 enabled is the default operating mode for the EX USB controller. In Report 1,
the controller sends a continuous stream of data packets when the sensor is touched. The
controller sends the data as long as a touch continues on the sensor.
Because Report 1 sends touch data continually, it is the most versatile mode, and it
provides the best response time and overall feel.
3M Touch Systems recommends that the touch driver generate an event as each packet in
the data stream arrives. Because touchdown and liftoff events are specially coded, your
software can generate mouse events that correspond to what the user is doing.
This is a request to perform a 2-point calibration. The calibration can be performed at
points inset from the lower left and upper right corners (extended calibration) or it can be
done at those corners. This is equivalent to the Calibrate Extended (12.5% insets from the
lower left and upper right corners) command used by 3M™ MicroTouch™ serial
controllers. The 2-point calibration defines the active area of the sensor by mapping two
targets displayed on the video image to absolute X and Y coordinates on the sensor.
Table 8. Calibration Request
The direction bit in bmRequestType has been set to 0 (host-to-device). This request does
not require that the device return any data. The byte bRequest is set to 4 to indicate that
this is the calibration command.
The wValue field is used to select the type of calibration to be performed. This value can
be either 1 for Extended (or Inset) or 2 for Corner.
The controller does not use the wIndex field. This field should be set to zero to ensure
future compatibility.
Offset
0
1
2
4
6
Field
bmRequestType
bRequest
wValue
wIndex
wLength
3M Touch Systems, Inc. Proprietary Information
Size
1
2
2
2
1
Value
01000000
4
0xXXXX
0x0000
0
Description
Characteristics
Command number
Calibration type
Not used
No data phase
19