2811271 Phoenix Contact, 2811271 Datasheet - Page 15

PROGRAMING ADAPTER USB INTERFACE

2811271

Manufacturer Part Number
2811271
Description
PROGRAMING ADAPTER USB INTERFACE
Manufacturer
Phoenix Contact
Datasheet

Specifications of 2811271

Accessory Type
IFS-USB-Programming Adapter
For Use With/related Products
UPS Systems
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
IFS-USB-PROG-ADAPTER
9.6
Battery management of the TRIO-UPS is divided into two
checks that are performed cyclically during normal
operation.
Battery presence check
The battery presence check is used to detect a correctly
installed battery. If this is not the case, the check is failed
and the green 0 and red 8 LED indicators are controlled
statically.
Battery quality check
The battery quality check is a lifecycle test. It enables
conclusions to be drawn, e.g., regarding the maximum
lifecycle of the battery if the maximum charging time has
been exceeded. In this case, the green 0 and red 8 LED
indicators are controlled statically.
10
10.1
The TRIO-UPS is connected to the USB connection on the
service PC via the "Config.-Port" using the IFS-USB-PROG-
ADAPTER data cable.
10.2
The programming adapter (Order No. 2811271) represents
the interface between the service PC and the TRIO-UPS
and is required in order to parameterize the TRIO-UPS.
Figure 11
104103_en_00
Battery management
Interfaces
Config.-Port
IFS-USB-PROG-ADAPTER
Programming adapter
10.3
The IFS-CONFSTICK is a multi-functional memory block for
easy storage and back up of configuration and parameter
data.
Transferring parameters to the IFS-CONFSTICK
To transfer parameters, proceed as follows:
1. Press and hold down the "Confirm" button.
2. You now have four seconds to carefully insert the
3. Parameter transfer is started and indicated by the cyclic
Transferring parameters to the TRIO-UPS
To transfer parameters, proceed as follows:
1. Carefully insert the IFS-CONFSTICK in the "Config.-
1. Press and hold down the "Confirm" button for at least
2. Parameter transfer is started and indicated by the cyclic
The following can be parameterized:
IFS-CONFSTICK in the "Config.-Port" on the
TRIO-UPS, taking care to observe the connection
direction.
control of the three LED indicators. Sequence: Red -
Yellow - Green
a) Error-free transfer:
b) Transfer error:
Port" on the TRIO-UPS, taking care to observe the
connection direction.
six seconds.
control of the three LED indicators. Sequence: Green -
Yellow - Red
a) Error-free transfer:
b) Transfer error:
Times
Switching outputs
Battery management
IFS-CONFSTICK
Green LED indicator ON
Red LED indicator ON
Green LED indicator ON
Red LED indicator ON
TRIO-UPS/1AC/24DC/5
PHOENIX CONTACT
15