TLP3042SCFT Toshiba, TLP3042SCFT Datasheet - Page 64

PHOTOCOUPLER ZC TRIAC OUT 6-DIP

TLP3042SCFT

Manufacturer Part Number
TLP3042SCFT
Description
PHOTOCOUPLER ZC TRIAC OUT 6-DIP
Manufacturer
Toshiba
Datasheets

Specifications of TLP3042SCFT

Voltage - Isolation
5000Vrms
Number Of Channels
1
Voltage - Off State
400V
Output Type
AC, Triac, Zero Cross
Current - Gate Trigger (igt) (max)
10mA
Current - Hold (ih)
600µA
Current - Dc Forward (if)
20mA
Current - Output / Channel
100mA
Mounting Type
Through Hole
Package / Case
6-DIP
Output Device
PhotoTriac
Isolation Voltage
5000 V
Peak Output Voltage (vdrm)
400 V
Maximum Input Voltage
120 VAC
Maximum Output Voltage
400 V
Minimum Trigger Current
5 mA
Configuration
1 Channel
Maximum Continuous Output Current
100 mA
Maximum Input Current
25 mA
Maximum Operating Temperature
+ 100 C
Maximum Power Dissipation
330 mW
Maximum Reverse Diode Voltage
5 V
Minimum Operating Temperature
- 40 C
Mounting Style
Through Hole
Zero-crossing Circuit
Yes
Number Of Elements
1
Forward Voltage
1.3V
Repetitive Peak Off-state Volt
400V
Operating Temp Range
-25C to 85C
Output Current
100mA
Package Type
PDIP
Reverse Breakdown Voltage
5V
Mounting
Through Hole
Pin Count
5
Trigger Current
5mA
Zero Crossing Circuit
Yes
Operating Temperature Classification
Commercial
Forward Current
50mA
Power Dissipation
330mW
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
TLP3042(S,C,F)
TLP3042(S,C,F,T)
TLP3042SF
9
For example, let's calculate the operating life of the GaAs LED, based on the data shown on page 60.
Here is an example of how to read an operating life, assuming that the ambient temperature (Ta) is 40°C and that the failure
criterion is a 30% decrease in light output.
Suppose that the initial LED current, IF, is 20 mA. Since the horizontal axis of the failure criteria graph is the reciprocal of absolute
temperature, it is necessary to convert the ambient temperature (Ta) to the reciprocal of absolute temperature (T):
The graph shows the projected lifetimes for F50% and F0.1% cumulative failure probabilities in solid and dashed lines respectively.
Normally, it is recommended to use F0.1% lines.
As X = 3.19, its intersection with the IF = 20 mA line for F0.1% is approximately 80,000 hours. (This figure is for reference only.)
You can also estimate the projected operating life from the projected light output degradation data.
Reading the Projected LED Operating Life Graph
Device Degradation
T =
Ta + 273.15
1
=
10000000
1000000
100000
40 + 273.15
80000
10000
1000
140
120
100
100
80
70
60
40
20
0
227
2.0
1
1
–30%
I
I
I
I
I
F
F
F
F
F
150
Failure criteria for light output degradation Δ P O < –30%
= 10mA
= 20mA
= 30mA
= 40mA
= 50mA
10
3.19 × 10
100 85
Test conditions: I
3.0
60
3.19
100
−3
40
Test time (h)
64
F
25
= 20 mA, Ta = 40°C
1000
0
4.0
I
I
I
I
I
−20
F
F
F
F
F
= 10mA
= 20mA
= 30mA
= 40mA
= 50mA
Projected F50%
operating life
Projected F0.1%
operating life
Ambient Temperature (°C)
10000
X-3σ
−50
1/K(×10
X
80000
100000
−73
5.0
–3
)

Related parts for TLP3042SCFT