MAX6683AUB+T Maxim Integrated Products, MAX6683AUB+T Datasheet - Page 8

IC TEMP SENSOR MON 10-UMAX

MAX6683AUB+T

Manufacturer Part Number
MAX6683AUB+T
Description
IC TEMP SENSOR MON 10-UMAX
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6683AUB+T

Function
Temp Monitoring System (Sensor)
Topology
ADC, Multiplexer, Register Bank
Sensor Type
Internal
Sensing Temperature
-40°C ~ 125°C
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
10-MSOP, Micro10™, 10-uMAX, 10-uSOP
Full Temp Accuracy
+/- 3 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
10 bit + Sign
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The POR state of the T
+80°C. The POR state of the T
0001 or +65°C.
High and low limits for the voltage inputs are stored in
registers 2Bh through 32h. If a measured voltage is less
than V
The POR states of the high and low voltage limits are
1.1 and 0.9 times the nominal voltage for each input.
Temperature Sensor and
System Monitor in a 10-Pin µMAX
Table 4. Configuration Register (Address 40h, Power-On Default = 08h)
Table 5. Interrupt Status Register (Address 41h, Power-Up Default = 00h)
8
5, 6, 7
_______________________________________________________________________________________
BIT
BIT
0
1
2
3
4
0
1
2
3
4
5
6
7
LOW
or greater than V
Line Frequency
ALERT Enable
2.5V
1.8V
Temp-Error
ALERT Clear
5V
V
Reserved
Short Cycle
Start/Stop
Reserved
Reserved
CC
NAME
IN
NAME
Select
Reset
IN
IN
-Error
-Error
-Error
-Error
HOT
HIGH
register is 0101 0000 or
READ/WRITE
, an ALERT is asserted.
READ/WRITE
HYST
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R
R
register is 0100
This bit controls the monitoring loop. Setting the bit to zero stops the
monitoring loop and puts the device into shutdown mode. The I
interface is still active during the shutdown mode. Setting the bit to 1 starts the
monitoring cycle. All high/low limits should be set before setting this bit to 1.
This bit is used to enable or disable the ALERT output. Setting the bit to 1
enables the ALERT output; setting the bit to 0 disables the ALERT output.
This bit is used to clear the ALERT output when it is set to high. It does not
affect the Interrupt Status Register. The monitoring loop does not start until the
bit is set to zero.
This bit controls the internal clock frequency. Setting the bit to 1 changes the
clock frequency to 51.2kHz from 61.4kHz. This can improve the measurement
accuracy when the power-line frequency is at 50Hz.
This bit reduces the conversion time by a factor of 4 when it is set to 1.
This bit is used as a reset signal for the register initialization. The 1 of this bit
resets all the register values into the power-up default mode, including bit 7
itself.
A 1 i nd i cates ei ther a hi g h or l ow l i m i t has b een exceed ed at the 2.5V
A 1 i nd i cates ei ther a hi g h or l ow l i m i t has b een exceed ed at the 1.8V
A 1 i nd i cates ei ther a hi g h or l ow l i m i t has b een exceed ed at the 5V
A 1 i nd i cates ei ther a hi g h or l ow l i m i t has b een exceed ed at the V
A 1 indicates either a high or low limit has been exceeded at the internal
temperature sensor. The conditions that generate and clear this bit depend
on the temperature interrupt mode selected by bits 0 and 1 in the
Temperature Configuration Register.
The Interrupt Status Register records temperature or
voltage fault conditions whenever a limit is exceeded
(Table 5). Bits 0 through 3 correspond to the 2.5V, 1.8V,
5V, and V
the temperature. If a threshold has been crossed, the
appropriate bit contains a 1. In the default and one-time
interrupt modes, reading the status register clears the
register until a new out-of-range condition is detected.
CC
DESCRIPTION
voltage inputs and bit 4 corresponds to
Interrupt Status Byte Functions
DESCRIPTION
2
C/SMBus
C C
IN
IN
I N
i np ut.
i np ut.
i np ut.
i np ut.