W83791G Nuvoton Technology Corporation of America, W83791G Datasheet - Page 79

no-image

W83791G

Manufacturer Part Number
W83791G
Description
IC MONITOR H/W 48-LQFP
Manufacturer
Nuvoton Technology Corporation of America
Datasheet

Specifications of W83791G

Function
Hardware Monitor
Topology
ADC
Sensor Type
External
Sensing Temperature
External Sensor
Output Type
I²C™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
48-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
W83791G
Manufacturer:
NXP
Quantity:
6 000
Part Number:
W83791G
Manufacturer:
Nuvoton Technology Corporation of America
Quantity:
10 000
Part Number:
W83791G
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Temperature: Get Event Data message, continued.
Entity ID
Entity instance
Event status index
Event status
Event Severity
ASF PACKET DATA
Temperature 1: 07h (System board)
Temperature 2/3: 03h (Processor)
These are defined in Table 28-11 of IPMI v1.0 specification. This value is
programmable because that may be used in add-in-card or connected to
other device.
Temperature 1: 01h (main system board).
Temperature 2: 01h (Processor 1)
Temperature 3: 02h (Processor 2)
These are programmable.
Temperature 1: 0Dh (zero-based)
Temperature 2: 0Eh
Temperature 3: 0Fh
The reference table of ASF 0.64 is shown as following.
Monitor (0x01): That is represented the monitored temperature is under the
lower temperature.
Non Critical (0x08): that is represented the temperature is located between
the lower and upper temperature.
Critical Condition (0x10): that is represented the monitored temperature is
over the upper temperature.
Lower Temp.
Status
Value
0000_0010b Deasserted (send) Refer as above figure.
0000_0011b Asserted (send)
0000_0111b Event Status End
Upper Temp.
Status type
Critical Condition (0x10)
Non Critical (0x08)
Monitor (0x01)
- 73 -
TEMPERATURE 1
Description
W83791D/G will respond
all relative information.
When event status index
is more than 10h, the
machine will be ended
the transmission.
Publication Release Date: April 14, 2006
W83791D/G
Byte Count
0Bh
0Bh
02h
Revision 1.1

Related parts for W83791G