TLE7230R Infineon Technologies, TLE7230R Datasheet - Page 11

no-image

TLE7230R

Manufacturer Part Number
TLE7230R
Description
IC SW SMART OCTAL LOWSIDE PDSO36
Manufacturer
Infineon Technologies
Type
Low Sider
Datasheets

Specifications of TLE7230R

Input Type
SPI
Number Of Outputs
8
On-state Resistance
800 mOhm
Current - Peak Output
2A
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
DSO-36
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output / Channel
-
Other names
SP000067170
SP000311685
TLE7230R
TLE7230RNT
TLE7230RT
TLE7230RT
TLE7230RTR
TLE7230RXT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE7230R
Manufacturer:
INFINEON
Quantity:
5 510
Part Number:
TLE7230R
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
TLE7230R
0
Part Number:
TLE7230R1
Manufacturer:
SEMTECH
Quantity:
471
SPI Diagnostics:
As soon as a fault occurs for longer than the fault filtering time, the fault information is latched into the
diagnosis register (the Fault pin will also change from high to low state). A new error on the same chan-
nel will overwrite the old error report. Serial data out pin (SO) is in high impedance state when CS is
high. If CS receives a LOW signal, all diagnosis bits can be shifted out serially. If the sent command is
valid the rising edge of CS will reset all diagnosis registers and restart the fault filtering time. In case of
an invalid command the device will ignore the data bits and the diagnosis register will not be reset at the
rising CS edge.
Figure 1: Two bits per channel diagnostic feedback
For Full Diagnosis there are two dedicated diagnostic bits per channel, as shown in Figure 1.
Normal function: The bit combination HH indicates that there is no fault condition, i.e. normal function.
Overload, Shorted Load or Overtemperature: HL is set if the current limitation becomes active, i.e.
in the event of an overload or short to supply event. Additionally, this bit combination is set in the event of
overtemperature of the corresponding channel.
Open load: LH is set if an open load is detected (in off state of the channel)
Short to GND: LL is set if a short to ground condition is detected (in off state)
Timing Figures
Figure 5: Power Outputs
V2.0
V
80%
20%
V
DS
IN
Diagnostic Serial Data Out SO
H H
H L
L H
L L
MSB
15
Ch. 8
t
ON
N o r m a l function
Overload , Shorted Load or Overtemperature
O p e n Load (off)
Short to GND
Ch.2
t
OFF
3
Page
2
C h.1
1
11
D a t a S h e e t T L E 7 2 3 0 R
t
t
LSB
0
2005-10-05