LDP10IG10-A Panduit Corp, LDP10IG10-A Datasheet - Page 39

no-image

LDP10IG10-A

Manufacturer Part Number
LDP10IG10-A
Description
RACEWAY 1CHAN LG AD LGY(10=10')
Manufacturer
Panduit Corp
Series
Pan-Way™r
Datasheet

Specifications of LDP10IG10-A

Wire Duct Type
Solid (Raceway), Single Channel
Height
0.860" (21.80mm)
Length
10.00' (3.05m)
Width
1.51" (38.4mm)
Mounting Type
Adhesive
Features
Attached Latching Lid
Color
Gray, Light
Quick Wire Fill Capacities for TG-70 Raceway
This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to
the wire installation methods, straightness of wires, etc.
SPEC = 40% wire fill — The recommended design in cable capacity,
leaves room for future moves, adds and changes.
4A.
4B.
5A.
5B.
1.
2.
3.
TG70: Data only using Screw-on
Faceplates and Devices.
TG70: Data only using Snap-on
Faceplates and Wire Retainer.
TG70: Wire Retainer without devices.
TG70: Divided power and data (A).
TG70: Divided power and data (B).
TG70: Power and data using Snap-on
Faceplates and 3 Sided Power Box (A).
TG70: Power and data using Snap-on
Faceplates and 3 Sided Power Box (B).
using Screw-on Faceplates
Wirefill #1: With Data only
Raceway Type & Configuration
A = 10.09 in
CR-SR-TG70-Wirefill1
and devices.
2
A = 3.16 in
Wirefill #4: Divided (see 5A
and 5B for power and
data applications).
2
10.85
10.09
10.68
Area
(in²)
3.16
3.08
5.58
Fill
7.2
A = 7.20 in
For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).
14 AWG 12 AWG 10 AWG
MAX
.105
40
28
28
(UL Temp Rise Test)
Electrical Cables
THHN/T90
Wirefill #2: With Data only
using Snap-on Faceplates
2
FILL
MAX
.122
40
28
28
and Wire Retainer.
A = 10.68 in
MAX
.153
38
26
26
Data Grade Cable Data Grade Cable
MAX for Data = 60% wire fill — The maximum cable quantity
based on cable interweaving and packing factors.
MAX for Power wire fill — The maximum number of electrical
cables based on UL temperature rise test.
SPEC
(40%)
24 AWG/UTP CM
92
97
99
28
65
28
51
Cat 5e (4pr)
DIA. = .217
2
Wirefill #5: With Power and data
FILL
A = 3.08 in
using Snap-on Faceplates and
(60%)
MAX
138
146
148
43
98
42
76
3-Sided Power Box.
2
SPEC
(40%)
24 AWG/UTP CM
88
25
82
87
58
25
45
DIA. = .250
Cat 6 (4pr)
A = 5.58 in
FILL
(60%)
MAX
123
130
132
38
88
37
68
Wirefill #3: With Wire Retainer.
2
SPEC
(40%)
Coax Cable
53
56
57
17
38
16
30
DIA. = .275
FILL
RG6
A = 10.85 in
(60%)
MAX
80
85
86
25
57
24
44
Fiber Optic Cable
SPEC
(40%)
164
174
177
117
51
50
91
2
DIA. = .175
2 Strand
FILL
(60%)
MAX
247
261
265
176
136
77
75
E9
Faceplate,
Furniture
LD Profile
Overview
Selection
Technical
Ultimate
Labeling
Twin-70
Boxes &
System
System
Office
Outlet
Quick
Guide
TG-70
Index
Cove
T130
T-70
T-45
Pole
Info
ID
&