UBA2071T/N1,118 NXP Semiconductors, UBA2071T/N1,118 Datasheet - Page 22

no-image

UBA2071T/N1,118

Manufacturer Part Number
UBA2071T/N1,118
Description
IC DRIVER HALF BRIDGE 24SOIC
Manufacturer
NXP Semiconductors
Type
CCFL/EEFL Controllerr
Datasheet

Specifications of UBA2071T/N1,118

Package / Case
24-SOIC (0.300", 7.50mm Width)
Frequency
38 ~ 42kHz
Current - Supply
1.5mA
Voltage - Supply
14V
Operating Temperature
-25°C ~ 100°C
Driver Type
CCFL Drivers
Operating Supply Voltage
14 V
Maximum Operating Temperature
+ 100 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 25 C
Supply Current
1.5 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
935285139118
NXP Semiconductors
UBA2071_A_1
Product data sheet
8.14.8 Ignition Failure (IF)
8.14.9 The NONFAULT pin
duration longer than t
the control circuits that arcing has been detected. When arcing is detected, PWM dimming
is disabled and the fault timer is started.
When the current control loop comes close to its regulation point, the lamps are assumed
to be on (ignited). This is when the average absolute voltage on the IFB pin is above
V
frequency has reached f
disabled and the fault timer is started.
The NONFAULT pin provides bidirectional signalling of the fault status between the IC and
any external circuit. When no fault is detected, the voltage on the pin is pulled high to
V
An external circuit can signal to the IC that a fault has been detected by pulling a current
larger than I
from the pin and start the fault timer. To prevent interference with the PWM dimming, the
IC will only look at the NONFAULT pin during the period when the lamp current regulation
loop is closed (when
When the IC detects an internal fault, see
via the NONFAULT pin by pulling the pin down (after the fault output delay time t
At this point the IC can no longer detect the external fault. However, by then the fault timer
is already running.
Fig 17. Input and output levels at the NONFAULT pin
th(lod)(IFB)
oc(NONFAULT)
. If the lamps are not on when the ignition sweep is finished, (switching
I
sc(NONFAULT)
trig(I)NONFAULT
by an internal current source.
load line
out: high (inactive)
in: low (active)
spike(min)
V
CSWP
Rev. 01 — 23 June 2008
sw(min)
from the NONFAULT pin. The IC will detect the current drawn
I
trig(I)NONFAULT
. Each spike will trigger an internal one-shot, which signals to
=
), then an ignition failure is detected, PWM dimming is
out: high (inactive)
NONFAULT
in: high (inactive)
V
pin voltage
CVFB
1 V
).
0
Section 8.14.2
Half bridge control IC for CCFL backlighting
V
V
UBA2071; UBA2071A
oc(NONFAULT)
trig(I)NONFAULT
out: low (active)
in: unknown
to
Section
I
sink(NONFAULT)
8.14.8), it signals this
© NXP B.V. 2008. All rights reserved.
NONFAULT
pin current
014aaa113
d(o)fault)
22 of 35
).

Related parts for UBA2071T/N1,118