LTC4214-2CMS Linear Technology, LTC4214-2CMS Datasheet - Page 27

IC CTRLR HOTSWAP NEGVOLT 10MSOP

LTC4214-2CMS

Manufacturer Part Number
LTC4214-2CMS
Description
IC CTRLR HOTSWAP NEGVOLT 10MSOP
Manufacturer
Linear Technology
Type
Hot-Swap Controllerr
Datasheet

Specifications of LTC4214-2CMS

Applications
General Purpose
Internal Switch(s)
No
Voltage - Supply
6 V ~ 16 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
10-TFSOP, 10-MSOP (0.118", 3.00mm Width)
Linear Misc Type
Negative Low Voltage
Family Name
LTC4214-2
Package Type
MSOP
Operating Supply Voltage (min)
-6V
Operating Supply Voltage (max)
-16V
Operating Temperature (min)
0C
Operating Temperature (max)
70C
Operating Temperature Classification
Commercial
Product Depth (mm)
3mm
Product Height (mm)
0.86mm
Product Length (mm)
3mm
Mounting
Surface Mount
Pin Count
10
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LTC4214-2CMS
Manufacturer:
LT
Quantity:
10 000
APPLICATIO S I FOR ATIO
Shutdown Cooling Cycle (LTC4214-2)
Figure 15 shows the timer behavior of the LTC4214-2. At
time point 2, TIMER exceeds V
immediately and the LTC4214 shuts down. TIMER starts
a shutdown cooling cycle by discharging TIMER with 5 A
to the V
the V
TMRH
TMRL
threshold. There are four 5 A discharge phases
threshold. TIMER then charges with 5 A to
PWRGD
40 A + 8 • I
SENSE
TIMER
DRAIN
GATE
Figure 15. Shutdown Cooling Timing Behavior of LTC4214-2 (All Waveforms are Referenced to V
V
OUT
SS
U
DRN
1
CB
CIRCUIT BREAKER TIMES OUT
5 A
2
U
V
TMRL
TMRH
5 A
W
, GATE pulls down
5 A
SHUTDOWN COOLING
5 A
U
5 A
5 A
20 • (V
20 • (V
and three 5 A charge phases in this shutdown cooling
cycle spanning time points 2 and 3. At time point 3, the
LTC4214 automatic retry occurs with a start-up cycle.
Good thermal management techniques are highly recom-
mended; power and thermal dissipation must be carefully
evaluated when implementing the automatic retry scheme.
ACL
CB
20 • V
5 A
V
GATEL
+ V
+ V
V
TMRH
OS
OS
OS
50 A
40 A + 8 • I
)
)
RETRY
3 4 5
LTC4214-1/LTC4214-2
START-UP
GATE
6
DRN
50 A
78 9 10
V
V
V
V
V
IN
ACL
CB
DRNCL
DRNL
– V
GATEH
5 A
EE
5 A
4214 F15
)
27
421412f

Related parts for LTC4214-2CMS