MAX5916AEUI+ Maxim Integrated Products, MAX5916AEUI+ Datasheet - Page 12

IC HOT-SWAP CTRLR DUAL 28-TSSOP

MAX5916AEUI+

Manufacturer Part Number
MAX5916AEUI+
Description
IC HOT-SWAP CTRLR DUAL 28-TSSOP
Manufacturer
Maxim Integrated Products
Type
Hot-Swap Controllerr
Datasheet

Specifications of MAX5916AEUI+

Applications
PCI 2.2 Server
Internal Switch(s)
No
Voltage - Supply
10.8 V ~ 13.2 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
28-TSSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The MAX5915/MAX5915A/MAX5916/MAX5916A are cir-
cuit-breaker ICs for hot-swap applications where a PCI
card is inserted into a slot that is connected to a live
backplane. Normally, when a card is plugged into a live
backplane, the card’s discharged capacitors provide a
low-impedance path that can momentarily cause the
main power supply to collapse. Both devices provide
startup current limiting and undervoltage/overcurrent
monitoring of two separate PCI card slots. Current limit-
ing and short-circuit protection are achieved using
external n-channel MOSFETs on the +3.3V and +5V
supply lines and internal MOSFETs on the ±12V and
+3.3V auxiliary supply lines.
External sense resistors monitor the output currents of
the +3.3V and +5V supplies. These external sense
resistors adjust the overcurrent trip threshold. PCI stan-
dards dictate maximum values for the supply power
and total power drawn from the backplane. The maxi-
mum power that any one PCI board can draw is 25W.
Table 1 lists PCI standard maximum voltage, current,
and power for each supply.
Table 1 illustrates that both the +5V and +3.3V supplies
can draw up to 25W. Total combination of output power
should be limited to 25W based on PCI standard.
The +12V input powers the internal circuitry of these
devices. The main supply outputs (3.3VO_, 5VO_,
+12VO_, and -12VO_) can become active only after
both of the following events have occurred:
Figure 1 displays typical startup waveforms. The main
supplies can be enabled without using the auxiliary
supply; however, PGOOD_ remains in a low state if the
Dual PCI 2.2 Hot-Swap Controllers
Table 1. PCI Standard Maximum Values
*Supply voltage is referenced to the output of the MAX5915/MAX5916.
12
V
threshold.
ON_ is driven high.
SUPPLY VOLTAGE (V)*
______________________________________________________________________________________
+12VIN
+3.3 aux (disabled)
+3.3 aux (enabled)
is above its undervoltage lockout (UVLO)
+3.3
+12
-12
+5
Detailed Description
VOLTAGE TOLERANCE (%)
Startup Mode
±0.3V
±10
±10
±10
±5
±5
auxiliary supply is not used.
The auxiliary supply (3.3VAUXO_) is available after both
of these events have occurred:
The internal circuitry for these devices monitors the out-
put voltage on all channels except the -12V supply. All
outputs are monitored for overcurrent. An undervoltage
condition occurs when any supply’s output voltage falls
below the set undervoltage level. An overcurrent fault
occurs when a monitored output current reaches the
set overcurrent threshold. Each supply has its own
overcurrent and undervoltage thresholds. If any of the
monitored voltages fall below their respective under-
voltage level, or if any of the monitored output currents
reach their overcurrent threshold, for a time period,
t
condition (see the Fault Management section).
External sense resistors monitor current through the
external MOSFETs of the +3.3V and +5V outputs, while
the current for the ±12V supplies are internally monitored.
A fault condition on one of the main outputs causes all
the channel’s main outputs to shut down after t
and then either latch off (MAX5915/MAX5915A) or auto-
matically restart after t
A fault on any of the channel’s main outputs does not
affect the channel’s auxiliary outputs.
Auxiliary output voltage and current are monitored inter-
nally. The +3.3V auxiliary output is independent of the
main outputs but the main outputs are dependent on
the auxiliary outputs. Fault conditions on the main out-
puts do not affect the auxiliary. A fault on the auxiliary
supply causes the controller to disable all of the affected
DELAY
Normal Operation +3.3V Auxiliary Output
MAX CURRENT (A)
V
AUXON_ is driven high.
3.3VAUXIN
, the controller disables the channel with the fault
0.375
0.02
7.6
0.5
0.1
5
is above its UVLO threshold.
Normal Operation +3.3V, +5V,
RESTART
(MAX5916/MAX5916A).
MAX POWER (W)
±12V Outputs
0.066
1.24
1.2
25
25
6
DELAY

Related parts for MAX5916AEUI+