CRD5490-Z Cirrus Logic, CRD5490-Z Datasheet - Page 23

no-image

CRD5490-Z

Manufacturer Part Number
CRD5490-Z
Description
Power Management IC Development Tools CS5463 Pwr Meas/Mntr Reference Design
Manufacturer
Cirrus Logic
Type
Energy Meterr
Datasheet

Specifications of CRD5490-Z

Rohs
yes
Product
Reference Design Boards
Tool Is For Evaluation Of
CS5490
Input Voltage
90 VAC to 260 VAC
Output Current
15 A
CRD5490-Z
3.3.6
Register Write/Read Tab
The Register Write/Read tab allows access to the CS5490 registers directly. See Figure 26.
Figure 26. Register Write/Read Tab - Read
There are two types of transactions: Write and Read. The CS5490 memory is organized by pages. In order to
properly write a register, it is necessary to set the Page, Address, and Data field and then click the Write button. To
read a register it is necessary to set the Page and Address and then click the Read button. Figure 26 shows the read
operation. The serial port traffic can be seen in the bottom left corner. The register result is displayed in the Data
Write/Read (hex) field. Refer to the CS5490 data sheet, entitled Two Channel Energy Measurement IC, for more
details on registers and commands. Note that the write data in the Port Communication field has an extra leading
command byte - “52” in the example. This is a read command for the MCU. Read data does not contain an extra byte.
Common CS5490 registers can be written to a file using the SAVE button in the Device Configuration panel. The
LOAD button is used to recall the common CS5490 registers that were previously saved. It is recommended to
configure the device using the Write button, start conversions from the Quick Measurements tab, stop conversions,
and then save the current configuration to a file.