CRD5490-Z Cirrus Logic, CRD5490-Z Datasheet - Page 16

no-image

CRD5490-Z

Manufacturer Part Number
CRD5490-Z
Description
Power Management IC Development Tools CS5463 Pwr Meas/Mntr Reference Design
Manufacturer
Cirrus Logic
Type
Energy Meterr
Datasheet

Specifications of CRD5490-Z

Rohs
yes
Product
Reference Design Boards
Tool Is For Evaluation Of
CS5490
Input Voltage
90 VAC to 260 VAC
Output Current
15 A
3.3.5.1
In the AC Offset and Gain fields, the AC offset and gain registers for all channels are displayed in hexadecimal
format. These registers can be modified directly by typing values in the fields and then pressing Enter on the
keyboard. The AC offset register only affects the current channel's I
3.3.5.2
To ensure accurate results, Gain calibration should be performed before AC offset calibration. The gain calibration
can be performed on both the voltage and current channels of the CS5490. The AC offset calibration can be
performed only on the current channel. In the CS5490, the initial values in the calibration registers affect the results
of the calibration. The register values are shown in blue in Figure 14. Before calibration, the gain and offset registers
should be configured in their default state 0x 40 0000 (gain = 1) for gain registers and 0x 00 0000 (clear = 0) for
offset registers.
Gain Calibration
For gain calibration, the CRD5490-Z software configures the gain registers prior to setting up calibration based on
the reference meter readings. The CRD5490-Z software uses the non-full scale gain calibration techniques and
formulas in Appendix 3: Non-Full Scale Gain Calibration (see page 33) to set up the CS5490 voltage and current
channel gain registers before calibration. The AC offset register values are not modified by the software, and the
current configuration are used. The default AC offset register value should be 0x 00 0000.
1. Attach an AC reference meter as configured in Figure 16. It is important to use short and large gauge wires to
2. Attach and turn on an AC source.
3. Attach and turn on AC load. For this example, a 200W light bulb is used, but it is recommended to use a load
16
attach the reference power meter to reduce error.
that is at a minimum of ½ of the full-scale load current.
AC Offset / Gain Register
Performing Calibrations
SOURCE
AC
Figure 16. Gain Calibration Configuration
CRD5490-Z
GUI
USB
*
Reference
RMS
Power
Meter
(V, A)
register values.
Load
AC
CRD5490-Z
DS988RD1