ATXMEGA64A3-MU Atmel, ATXMEGA64A3-MU Datasheet - Page 33

no-image

ATXMEGA64A3-MU

Manufacturer Part Number
ATXMEGA64A3-MU
Description
8-bit Microcontrollers - MCU 8/16 bit 1.6V-3.6V 64KB + 4KB
Manufacturer
Atmel
Datasheet

Specifications of ATXMEGA64A3-MU

Product Category
8-bit Microcontrollers - MCU
Rohs
yes
Core
AVR
Data Bus Width
8 bit/16 bit
Maximum Clock Frequency
32 MHz
Program Memory Size
64 KB
Data Ram Size
4 KB
On-chip Adc
Yes
Package / Case
QFN EP
Mounting Style
SMD/SMT
A/d Bit Size
12 bit
A/d Channels Available
8
Data Rom Size
2 KB
Interface Type
I2C, SPI, USART
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
50
Number Of Timers
7
Processor Series
ATXMega
Program Memory Type
Flash
Factory Pack Quantity
260
Supply Voltage - Max
3.6 V
Supply Voltage - Min
1.6 V
17. AWEX - Advanced Waveform Extension
17.1
17.2
8068T–AVR–12/10
Features
Overview
The Advanced Waveform Extension (AWEX) provides extra features to the Timer/Counter in
Waveform Generation (WG) modes. The AWEX enables easy and safe implementation of for
example, advanced motor control (AC, BLDC, SR, and Stepper) and power control applications.
Any WG output from a Timer/Counter 0 is split into a complimentary pair of outputs when any
AWEX feature is enabled. These output pairs go through a Dead-Time Insertion (DTI) unit that
enables generation of the non-inverted Low Side (LS) and inverted High Side (HS) of the WG
output with dead time insertion between LS and HS switching. The DTI output will override the
normal port value according to the port override setting. Optionally the final output can be
inverted by using the invert I/O setting for the port pin.
The Pattern Generation unit can be used to generate a synchronized bit pattern on the port it is
connected to. In addition, the waveform generator output from Compare Channel A can be dis-
tributed to, and override all port pins. When the Pattern Generator unit is enabled, the DTI unit is
bypassed.
The Fault Protection unit is connected to the Event System. This enables any event to trigger a
fault condition that will disable the AWEX output. Several event channels can be used to trigger
fault on several different conditions.
The AWEX is available for TCC0. The notation of this is AWEXC.
Output with complementary output from each Capture channel
Four Dead Time Insertion (DTI) Units, one for each Capture channel
8-bit DTI Resolution
Separate High and Low Side Dead-Time Setting
Double Buffered Dead-Time
Event Controlled Fault Protection
Single Channel Multiple Output Operation (for BLDC motor control)
Double Buffered Pattern Generation
XMEGA A3
33