ATXMEGA64A3-MU

Manufacturer Part Number
ATXMEGA64A3-MU
Description
8-bit Microcontrollers - MCU 8/16 bit 1.6V-3.6V 64KB + 4KB
Manufacturer
Atmel
Datasheet

Specifications of ATXMEGA64A3-MU

Product Category
8-bit Microcontrollers - MCU
Rohs
yes
Core
AVR
Data Bus Width
8 bit/16 bit
Maximum Clock Frequency
32 MHz
Program Memory Size
64 KB
Data Ram Size
4 KB
On-chip Adc
Yes
Package / Case
QFN EP
Mounting Style
SMD/SMT
A/d Bit Size
12 bit
A/d Channels Available
8
Data Rom Size
2 KB
Interface Type
I2C, SPI, USART
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
50
Number Of Timers
7
Processor Series
ATXMega
Program Memory Type
Flash
Factory Pack Quantity
260
Supply Voltage - Max
3.6 V
Supply Voltage - Min
1.6 V
10. System Clock and Clock options
10.1
10.2
8068T–AVR–12/10
Features
Overview
XMEGA A3 has an advanced clock system, supporting a large number of clock sources. It incor-
porates both integrated oscillators, external crystal oscillators and resonators. A high frequency
Phase Locked Loop (PLL) and clock prescalers can be controlled from software to generate a
wide range of clock frequencies from the clock source input.
It is possible to switch between clock sources from software during run-time. After reset the
device will always start up running from the 2 Mhz internal oscillator.
A calibration feature is available, and can be used for automatic run-time calibration of the inter-
nal 2 MHz and 32 MHz oscillators. This reduce frequency drift over voltage and temperature.
A Crystal Oscillator Failure Monitor can be enabled to issue a Non-Maskable Interrupt and
switch to internal oscillator if the external oscillator fails.
cipal clock system in XMEGA A3.
Fast start-up time
Safe run-time clock switching
Internal Oscillators:
External clock options
PLL with internal and external clock options with 2 to 31x multiplication
Clock Prescalers with 2 to 2048x division
Fast peripheral clock running at 2 and 4 times the CPU clock speed
Automatic Run-Time Calibration of internal oscillators
Crystal Oscillator failure detection
– 32 MHz run-time calibrated RC oscillator
– 2 MHz run-time calibrated RC oscillator
– 32.768 kHz calibrated RC oscillator
– 32 kHz Ultra Low Power (ULP) oscillator
– 0.4 - 16 MHz Crystal Oscillator
– 32.768 kHz Crystal Oscillator
– External clock
Figure 10-1 on page 19
XMEGA A3
shows the prin-
18