M24512-RDW6TP STMicroelectronics, M24512-RDW6TP Datasheet - Page 22

IC EEPROM 512KBIT 400KHZ 8TSSOP

M24512-RDW6TP

Manufacturer Part Number
M24512-RDW6TP
Description
IC EEPROM 512KBIT 400KHZ 8TSSOP
Manufacturer
STMicroelectronics
Datasheets

Specifications of M24512-RDW6TP

Format - Memory
EEPROMs - Serial
Memory Type
EEPROM
Memory Size
512K (64K x 8)
Speed
400kHz
Interface
I²C, 2-Wire Serial
Voltage - Supply
1.8 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Package / Case
8-TSSOP
Organization
64 K x 8
Interface Type
I2C
Maximum Clock Frequency
0.4 MHz
Access Time
900 ns
Supply Voltage (max)
5.5 V
Supply Voltage (min)
1.8 V
Maximum Operating Current
5 mA
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
2.5 V, 3.3 V, 5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-6349-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M24512-RDW6TP
Manufacturer:
SAMSUNG
Quantity:
10 940
Part Number:
M24512-RDW6TP
Manufacturer:
ST
0
Part Number:
M24512-RDW6TP
Manufacturer:
ST
Quantity:
150
Part Number:
M24512-RDW6TP
Manufacturer:
ST
Quantity:
20 000
Part Number:
M24512-RDW6TP
0
Device operation
3.18
3.19
22/42
Read Identification Page status (locked/unlocked)
The locked/unlocked status of the Identification page can be checked by issuing a specific
truncated instruction consisting of the Identification Page Write instruction followed by one
data byte. The data byte will be acknowledged if the Identification page is unlocked, while it
will not be acknowledged if the Identification page is locked.
Once the acknowledge bit of this data byte is read, it is recommended to generate a Start
condition followed by a Stop condition, so that:
Acknowledge in Read mode
For all Read instructions, the device waits, after each byte read, for an acknowledgment
during the 9
time, the device terminates the data transfer and switches to its Standby mode.
The instruction is truncated and not executed as the Start condition resets the device
internal logic.
The device is set to Standby mode by the Stop condition.
th
bit time. If the bus master does not drive Serial Data (SDA) Low during this
Doc ID 6757 Rev 21
M24256-BF, M24256-BR, M24256-BW, M24256-DR

Related parts for M24512-RDW6TP