MC10XS3412DHFK Freescale Semiconductor, MC10XS3412DHFK Datasheet - Page 27

no-image

MC10XS3412DHFK

Manufacturer Part Number
MC10XS3412DHFK
Description
Power Switch ICs - Power Distribution Eswitch Gen3 1012
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MC10XS3412DHFK

Rohs
yes
Number Of Outputs
4
Operating Supply Voltage
6 V to 20 V
Supply Current (max)
20 mA
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Package / Case
PQFN-24
Minimum Operating Temperature
- 40 C
Fail-safe and Fault.
contained in succeeding paragraphs.
depending on IN[x] input.
the following signals:
Analog Integrated Circuit Device Data
Freescale Semiconductor
IN_ON[x]
IN[x]
The 10XS3412 has four operating modes: Sleep, Normal,
The
The 10XS3412 transits to operating modes according to
• wake-up =
• fail = (V
IN_ON[2] or IN_ON[3],
timeout and FSI input not shorted to ground),
Figure 10
Figure 10. IN_ON[x] internal signal
Fail Safe
DD
Failure and VDD_FAIL_en) or (Watchdog
RST
describes an internal signal called IN_ON[x]
Table 6
(wake-up=0)
or WAKE or IN_ON[0] or IN_ON[1] or
and
(wake-up=1) and
(fail=1)
and (fault=0)
Figure 11
(fail=1) and
(wake-up=1)
and (fault=1)
summarize details
(fail=0) and (wake-up=1) and (fault=0)
(fail=1) and (wake-up=1) and (fault=0)
(fail=1)
(wake-up=1)
and (fault=0)
t
IN
(wake-up=0)
Figure 11. Operating Modes
OPERATIONAL MODES
and
Fault
Sleep
Table 6. 10XS3412 Operating Modes
Fail Safe
(wake-up=1)
and (fault=1)
Normal
x = Don’t care.
Mode
• fault = OC[0:3] or OT[0:3] or SC[0:3] or UV or (OV and
Sleep
Fault
OV_dis).
wake-up
(fail=0)
(wake-up=1)
and (fault=1)
(fail=0)
(wake-up=1)
and (fault=0)
0
1
1
1
(fail=0) and (wake-up=1) and (fault=0)
(wake-up=0)
and
fail fault
and
X
x
0
1
FUNCTIONAL DEVICE OPERATION
x
0
0
1
Normal
Device is in Sleep mode. All
outputs are OFF.
Device is currently in Normal
mode. Watchdog is active if
enabled.
Device is currently in Fail-safe
mode due to watchdog
timeout or V
conditions. The output states
depend on the corresponding
input in case the FSI is open.
Device is currently in Fault
mode. The faulted output(s) is
(are) OFF. The safe autoretry
circuitry is active to turn-on
again the output(s).
OPERATIONAL MODES
Comments
DD
Failure
10XS3412
27

Related parts for MC10XS3412DHFK